IMAGE QUALITY OF DIGITAL CHEST RADIOGRAPHY - EVALUATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - (PRELIMINARY-STUDY)

被引:1
|
作者
IKEZOE, J
KIDO, S
TAKEUCHI, N
KONDOH, H
ARISAWA, J
KOZUKA, T
机构
[1] Department of Radiology, Osaka University Medical School, Suita City, Osaka
关键词
IMAGE QUALITY; DIGITAL RADIOGRAPHY; STORAGE PHOSPHOR RADIOGRAPHY; RECEIVER OPERATING CHARACTERISTIC ANALYSIS;
D O I
10.1016/0169-2607(94)90195-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To evaluate the image quality of storage phosphor radiography (SR) for diagnosing subtle interstitial lung abnormalities, we studied the differences between conventional screen-film radiography (FR) and SR in 38 patients. Nineteen patients had subtle interstitial lung abnormalities and the others had normal chests. Two formats of hard copies were used for SR; a full-size SR (14 x 14 inches, 0.2-mm pixel size) and a minified SR (9 x 9 inches, 0.13-mm pixel size). Readings were carried out by 14 readers (7 chest radiologists and 7 residents). The area under the receiver operating characteristic curve was used to evaluate the results. For the 14 readers no significant differences in observer performance were observed among the three image sets (FR, full-size SR, minified SR), while for the seven chest radiologists significant differences were observed between FR and the two formats of SR. The best perceptual accuracy was obtained with FR as evaluated by the seven chest radiologists. In conclusion, while overall performance with digital and conventional radiographs was almost the same as far as diagnosing subtle interstitial lung abnormalities, significant differences between FR and SR were found by chest radiologists. Critically important information may be lost in commercially available SR.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [1] INTERPRETATION OF SUBTLE INTERSTITIAL CHEST ABNORMALITIES - CONVENTIONAL RADIOGRAPHY VERSUS HIGH-RESOLUTION STORAGE-PHOSPHOR RADIOGRAPHY - A PRELIMINARY-STUDY
    IKEZOE, J
    KOHNO, N
    KIDO, S
    TAKEUCHI, N
    JOHKOH, T
    ARISAWA, J
    KOZUKA, T
    JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) : 31 - 36
  • [2] Image quality of computed radiography and flat panel detector radiography: Evaluation of simulated subtle lung abnormalities
    Tagashira, H
    Arakawa, K
    Yoshimoto, M
    Yasuhara, Y
    Ikezoe, J
    Ogura, T
    RADIOLOGY, 2001, 221 : 354 - 354
  • [3] A computerized analysis system in chest radiography: Evaluation of interstitial lung abnormalities
    Kido, S
    Ikezoe, J
    Tamura, S
    Nakamura, H
    Kuroda, C
    JOURNAL OF DIGITAL IMAGING, 1997, 10 (02) : 57 - 64
  • [4] A computerized analysis system in chest radiography: Evaluation of interstitial lung abnormalities
    Shoji Kido
    Junpei Ikezoe
    Shinichi Tamura
    Hironobu Nakamura
    Chikazumi Kuroda
    Journal of Digital Imaging, 1997, 10 : 57 - 64
  • [5] FRACTAL ANALYSIS OF INTERSTITIAL LUNG ABNORMALITIES IN CHEST RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    NATTO, H
    TAMURA, S
    MACHI, S
    RADIOGRAPHICS, 1995, 15 (06) : 1457 - 1464
  • [6] Image quality of computed radiography with multi-objective frequency processing: Evaluation of simulated subtle lung abnormalities
    Nakayama, F
    Tagashira, H
    Arakawa, K
    Yoshimoto, M
    Ikezoe, J
    RADIOLOGY, 2002, 225 : 190 - 191
  • [7] Interpretation of subtle interstitial chest abnormalities: Conventional radiography versus high resolution storage phosphor radiography
    Ikezoe, J
    Kohno, N
    Takeuchi, N
    Kido, S
    Nakamura, H
    CAR '96: COMPUTER ASSISTED RADIOLOGY, 1996, 1124 : 27 - 29
  • [8] Evaluation of dose-image-quality optimization in digital chest radiography
    Lee, S. C.
    Wang, J. N.
    Liu, S. C.
    Jiang, S. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 544 - 547
  • [9] INTERPRETATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - CONVENTIONAL VERSUS STORAGE PHOSPHOR RADIOGRAPHY
    KIDO, S
    IKEZOE, J
    TAKEUCHI, N
    KONDOH, H
    TOMIYAMA, N
    JOKOH, T
    KOHNO, N
    TAKASHIMA, S
    YAMAGAMI, H
    NAITO, H
    ARISAWA, J
    MORIMOTO, S
    KOZUKA, T
    RADIOLOGY, 1993, 187 (02) : 527 - 533
  • [10] INTERPRETATION OF SUBTLE INTERSTITIAL CHEST ABNORMALITIES - CONVENTIONAL RADIOGRAPHY VERSUS HIGH-RESOLUTION STORAGE PHOSPHOR RADIOGRAPHY
    IKEZOE, J
    KOHNO, N
    TAKEUCHI, N
    KIDO, S
    ARISAWA, J
    NAKAMURA, H
    RADIOLOGY, 1995, 197 : 340 - 341