Atherosclerosis imaging using 3D black blood TSE SPACE vs 2D TSE

被引:19
|
作者
Wong, Stephanie K. [1 ,2 ]
Mobolaji-Iawal, Motunrayo [1 ,2 ]
Arama, Leron [1 ]
Cambe, Joy [1 ]
Biso, Sylvia [1 ]
Alie, Nadia [1 ]
Fayad, Zahi A. [1 ,2 ,3 ]
Mani, Venkatesh [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, One Gustave L,Levy Pl,Box 1234, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[3] Icahn Sch Med Mt Sinai, Marie Josee & Henry R Kravis Cardiovasc Hlth Ctr, Dept Med, Zena & Michael A Wiener Cardiovasc Inst, New York, NY 10029 USA
来源
WORLD JOURNAL OF RADIOLOGY | 2014年 / 6卷 / 05期
关键词
Atherosclerosis; Carotid artery plaque; Aorta; Femoral artery; Magnetic resonance imaging;
D O I
10.4329/wjr.v6.i5.192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare 3D Black Blood turbo spin echo (TSE) sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) vs 2D TSE in evaluating atherosclerotic plaques in multiple vascular territories. METHODS: The carotid, aortic, and femoral arterial walls of 16 patients at risk for cardiovascular or atherosclerotic disease were studied using both 3D black blood magnetic resonance imaging SPACE and conventional 2D multi-contrast TSE sequences using a consolidated imaging approach in the same imaging session. Qualitative and quantitative analyses were performed on the images. Agreement of morphometric measurements between the two imaging sequences was assessed using a two-sample t-test, calculation of the intra-class correlation coefficient and by the method of linear regression and Bland-Altman analyses. RESULTS: No statistically significant qualitative differences were found between the 3D SPACE and 2D TSE techniques for images of the carotids and aorta. For images of the femoral arteries, however, there were statistically significant differences in all four qualitative scores between the two techniques. Using the current approach, 3D SPACE is suboptimal for femoral imaging. However, this may be due to coils not being optimized for femoral imaging. Quantitatively, in our study, higher mean total vessel area measurements for the 3D SPACE technique across all three vascular beds were observed. No significant differences in lumen area for both the right and left carotids were observed between the two techniques. Overall, a significant-correlation existed between measures obtained between the two approaches. CONCLUSION: Qualitative and quantitative measurements between 3D SPACE and 2D TSE techniques are comparable. 3D-SPACE may be a feasible approach in the evaluation of cardiovascular patients. (C) 2014 Baishideng Publishing Group Inc. All rights reserved.
引用
收藏
页码:192 / 202
页数:11
相关论文
共 50 条
  • [1] Comparison between 2D TSE and 3D SPACE in the evaluation of craniocervical ligaments
    Bo Mi Chung
    Sujin Kim
    Younghee Yim
    Guen Young Lee
    [J]. European Spine Journal, 2023, 32 : 361 - 367
  • [2] Comparison between 2D TSE and 3D SPACE in the evaluation of craniocervical ligaments
    Chung, Bo Mi
    Kim, Sujin
    Yim, Younghee
    Lee, Guen Young
    [J]. EUROPEAN SPINE JOURNAL, 2023, 32 (01) : 361 - 367
  • [3] Cherenkov Imaging for TSE-3D Imaging
    Petroccia, H.
    Xie, Y.
    Miao, T.
    Zhu, Y.
    Bruza, P.
    Pogue, B.
    Zhu, T.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E152 - E152
  • [4] 3D CISS, 3D MP-PAGE and 2D TSE for MRI prior to cochlear implantation.
    Seitz, J
    Held, P
    Waldeck, A
    Völk, M
    Lenhart, M
    Strotzer, M
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (03): : 227 - 231
  • [5] Comparison between 3D SPACE FLAIR and 3D TSE FLAIR in Meniere's disease
    Bernaerts, Anja
    Janssen, Nick
    Wuyts, Floris L.
    Blaivie, Catherine
    Vanspauwen, Robby
    van Dinther, Joost
    Zarowski, Andrzej
    Offeciers, Erwin
    Deckers, Filip
    Casselman, Jan W.
    De Foer, Bert
    [J]. NEURORADIOLOGY, 2022, 64 (05) : 1011 - 1020
  • [6] 3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study
    Pieter Van Dyck
    Céline Smekens
    Ella Roelant
    Thijs Vande Vyvere
    Annemiek Snoeckx
    Eline De Smet
    [J]. European Radiology, 2022, 32 : 6456 - 6467
  • [7] 3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study
    Van Dyck, Pieter
    Smekens, Celine
    Roelant, Ella
    Vande Vyvere, Thijs
    Snoeckx, Annemiek
    De Smet, Eline
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (09) : 6456 - 6467
  • [8] Magnetic resonance imaging in the evaluation of cervical foraminal stenosis: comparison of 3D T2 SPACE with sagittal oblique 2D T2 TSE
    Barnaure, I
    Galley, J.
    Fritz, B.
    Sutter, R.
    [J]. SKELETAL RADIOLOGY, 2022, 51 (07) : 1453 - 1462
  • [9] Magnetic resonance imaging in the evaluation of cervical foraminal stenosis: comparison of 3D T2 SPACE with sagittal oblique 2D T2 TSE
    I. Barnaure
    J. Galley
    B. Fritz
    R. Sutter
    [J]. Skeletal Radiology, 2022, 51 : 1453 - 1462
  • [10] Understanding 3D TSE Sequences: Advantages, Disadvantages, and Application in MSK Imaging
    Glaser, Christian
    D'Anastasi, Melvin
    Theisen, Daniel
    Notohamiprodjo, Mike
    Horger, Wilhelm
    Paul, Dominik
    Horng, Annie
    [J]. SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2015, 19 (04) : 321 - 327