3D CISS, 3D MP-PAGE and 2D TSE for MRI prior to cochlear implantation.

被引:4
|
作者
Seitz, J [1 ]
Held, P
Waldeck, A
Völk, M
Lenhart, M
Strotzer, M
机构
[1] Univ Regensburg Klinikum, Inst Rontgendiagnost, D-93042 Regensburg, Germany
[2] Univ Regensburg Klinikum, Klin & Poliklin Hals Nasen Ohrenheilkunde, Regensburg, Germany
关键词
cochlear implant; Cl; inner ear; magnetic resonance imaging; MRI; computed tomography; CT; cochlear nerve;
D O I
10.1055/s-2000-104
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to determine the presurgical predictive value of high resolution MRI in patients scheduled for chochlear implantation. Method and Material: The presurgical MRI (3D CISS, 3D MP-RAGE with and without i.v. contrast medium, 2D TSE) findings of 54 patients and the intraoperative situation reported by the surgeon were compared retrospectively. The surgical and functional success of the cochlear implantation was evaluated. Results: We found a high degree of correlation between MRI and intraoperative findings concerning the patency of the whole cochlea and anomalies as well as in the diagnosis of pathology of the cochlear, vestibular and facial nerves and in anomalies of the internal auditory canal. However, in four out of 54 patients there was a false negative prediction regarding the patency of the cochlea. The sensitivity was 50% (4/8), the specificity 100% (46/46). Concerning the surgical success the accuracy was 100%. In all patients MRI gave sufficient anatomical information to the surgeon concerning the jugular bulb and the facial nerve. Conclusion: A high-resolution MRI protocol consisting of coronal 2D T2w TSE, 3D T2 * w transverse CISS; plain and contrast enhanced sagittal T1w 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation.
引用
收藏
页码:227 / 231
页数:5
相关论文
共 50 条
  • [1] MRI of inner ear anatomy using 3D MP-RAGE and 3D CISS sequences
    Held, P
    Fellner, C
    Fellner, F
    Seitz, J
    Strutz, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (833): : 465 - 472
  • [2] MRI of inner ear and facial nerve pathology using 3D MP-RAGE and 3D CISS sequences
    Held, P
    Fellner, C
    Fellner, F
    Seitz, J
    Graf, S
    Hilbert, M
    Strutz, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (834): : 558 - 566
  • [3] 2D SENSE for faster 3D MRI
    Weiger, M
    Pruessmann, KP
    Boesiger, P
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 14 (01): : 10 - 19
  • [4] 2D sense for faster 3D MRI
    Markus Weiger
    Klaas P. Pruessmann
    Peter Boesiger
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2002, 14 (1) : 10 - 19
  • [5] 3D and 2D/3D holograms model
    A. A. Boriskevich
    V. K. Erohovets
    V. V. Tkachenko
    [J]. Optical Memory and Neural Networks, 2012, 21 (4) : 242 - 248
  • [6] 2D or 3D?
    Mills, R
    [J]. COMPUTER-AIDED ENGINEERING, 1996, 15 (08): : 4 - 4
  • [7] A microfluidic device for 2D to 3D and 3D to 3D cell navigation
    Shamloo, Amir
    Amirifar, Leyla
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2016, 26 (01)
  • [8] Enhance the 3D Object Detection With 2D Prior
    Liu, Cheng
    [J]. IEEE ACCESS, 2024, 12 : 67161 - 67169
  • [9] Atherosclerosis imaging using 3D black blood TSE SPACE vs 2D TSE
    Wong, Stephanie K.
    Mobolaji-Iawal, Motunrayo
    Arama, Leron
    Cambe, Joy
    Biso, Sylvia
    Alie, Nadia
    Fayad, Zahi A.
    Mani, Venkatesh
    [J]. WORLD JOURNAL OF RADIOLOGY, 2014, 6 (05): : 192 - 202
  • [10] Hemimegalencephaly: 2D, 3D Ultrasound and MRI Correlation
    Romero, X. C.
    Molina, F. S.
    Pastor, E.
    Amaya, F.
    [J]. FETAL DIAGNOSIS AND THERAPY, 2011, 29 (03) : 257 - 260