Atherosclerosis imaging using 3D black blood TSE SPACE vs 2D TSE

被引:19
|
作者
Wong, Stephanie K. [1 ,2 ]
Mobolaji-Iawal, Motunrayo [1 ,2 ]
Arama, Leron [1 ]
Cambe, Joy [1 ]
Biso, Sylvia [1 ]
Alie, Nadia [1 ]
Fayad, Zahi A. [1 ,2 ,3 ]
Mani, Venkatesh [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, One Gustave L,Levy Pl,Box 1234, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Dept Radiol, New York, NY 10029 USA
[3] Icahn Sch Med Mt Sinai, Marie Josee & Henry R Kravis Cardiovasc Hlth Ctr, Dept Med, Zena & Michael A Wiener Cardiovasc Inst, New York, NY 10029 USA
来源
WORLD JOURNAL OF RADIOLOGY | 2014年 / 6卷 / 05期
关键词
Atherosclerosis; Carotid artery plaque; Aorta; Femoral artery; Magnetic resonance imaging;
D O I
10.4329/wjr.v6.i5.192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To compare 3D Black Blood turbo spin echo (TSE) sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) vs 2D TSE in evaluating atherosclerotic plaques in multiple vascular territories. METHODS: The carotid, aortic, and femoral arterial walls of 16 patients at risk for cardiovascular or atherosclerotic disease were studied using both 3D black blood magnetic resonance imaging SPACE and conventional 2D multi-contrast TSE sequences using a consolidated imaging approach in the same imaging session. Qualitative and quantitative analyses were performed on the images. Agreement of morphometric measurements between the two imaging sequences was assessed using a two-sample t-test, calculation of the intra-class correlation coefficient and by the method of linear regression and Bland-Altman analyses. RESULTS: No statistically significant qualitative differences were found between the 3D SPACE and 2D TSE techniques for images of the carotids and aorta. For images of the femoral arteries, however, there were statistically significant differences in all four qualitative scores between the two techniques. Using the current approach, 3D SPACE is suboptimal for femoral imaging. However, this may be due to coils not being optimized for femoral imaging. Quantitatively, in our study, higher mean total vessel area measurements for the 3D SPACE technique across all three vascular beds were observed. No significant differences in lumen area for both the right and left carotids were observed between the two techniques. Overall, a significant-correlation existed between measures obtained between the two approaches. CONCLUSION: Qualitative and quantitative measurements between 3D SPACE and 2D TSE techniques are comparable. 3D-SPACE may be a feasible approach in the evaluation of cardiovascular patients. (C) 2014 Baishideng Publishing Group Inc. All rights reserved.
引用
收藏
页码:192 / 202
页数:11
相关论文
共 50 条
  • [41] Optofluidic lenses for 2D and 3D imaging
    Huang, Hanyang
    Zhao, Yi
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2019, 29 (07)
  • [42] Improvement of T1 Contrast in Whole-brain Black-blood Imaging using Motion-sensitized Driven-equilibrium Prepared 3D Turbo Spin Echo (3D MSDE-TSE)
    Yoneyama, Masami
    Nakamura, Masanobu
    Takahara, Taro
    Takemura, Atsushi
    Obara, Makoto
    Tabuchi, Takashi
    Tatsuno, Satoshi
    Sawano, Seishi
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (01) : 61 - 65
  • [43] 2D vs 3D, implications on spatial memory
    Tavanti, M
    Lind, M
    [J]. IEEE SYMPOSIUM ON INFORMATION VISUALIZATION 2001, PROCEEDINGS, 2001, : 139 - 145
  • [44] Signaling reactions in 2D vs. 3D
    Huang, William Y. C.
    Boxer, Steven G.
    Ferrell, James E.
    [J]. BIOPHYSICAL JOURNAL, 2024, 123 (03) : 21A - 21A
  • [45] Power efficiency of 3D vs 2D ICs
    Chrzanowska-Jeske, M.
    Ahmed, Mohammad A.
    [J]. 2013 IEEE FAIBLE TENSION FAIBLE CONSOMMATION (FTFC), 2013,
  • [46] The nasopalatine canal revisited using 2D and 3D CT imaging
    Mraiwa, N
    Jacobs, R
    Van Cleynenbreugel, J
    Sanderink, G
    Schutyser, F
    Suetens, P
    van Steenberghe, D
    Quirynen, M
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (06) : 396 - 402
  • [47] 3D Passive Imaging of Ultrasound Cavitation using a 2D Array
    Boulos, Paul
    Varray, Francois
    Gilles, Bruno
    Bera, Jean-Christophe
    Cachard, Christian
    [J]. 2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [48] Improved Brachial Plexus Visualization Using an Adiabatic iMSDE-Prepared STIR 3D TSE
    Elisabeth Klupp
    Barbara Cervantes
    Nico Sollmann
    Franziska Treibel
    Dominik Weidlich
    Thomas Baum
    Ernst J. Rummeny
    Claus Zimmer
    Jan S. Kirschke
    Dimitrios C. Karampinos
    [J]. Clinical Neuroradiology, 2019, 29 : 631 - 638
  • [49] Comparison of T2-Weighted 3D-Space and T2-Weighted 2D-TSE Sequences in Lumbar Spine MR Imaging
    Qurat-ul-Ain
    Nadeem, Syed Farrukh
    Mirza, Tariq Mahmood
    Shafiq, Mazhar
    Batool, Zahida
    Khadijah-tul-Kubra
    [J]. ANNALS OF KING EDWARD MEDICAL UNIVERSITY LAHORE PAKISTAN, 2023, 29 (04): : 361 - 366
  • [50] Myocardial blood flow quantification with PET comparison of 3D vs 2D aquisition
    Schepis, T.
    Gaemperli, O.
    Valenta, I.
    Treyer, V.
    Burger, C.
    Burger, C.
    Koepfli, P.
    Kaufmann, P. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S170 - S170