EFFECT OF MAGNETIC-SUSCEPTIBILITY CONTRAST-MEDIUM ON MYOCARDIAL SIGNAL INTENSITY WITH FAST GRADIENT-RECALLED ECHO AND SPIN-ECHO MR-IMAGING - INITIAL EXPERIENCE IN HUMANS

被引:19
|
作者
SAKUMA, H
OSULLIVAN, M
LUCAS, J
WENDLAND, MF
SAEED, M
DULCE, MC
WATSON, A
BLEYL, KL
LAFRANCE, ND
HIGGINS, CB
机构
[1] NYCOMED SALUTAR,SUNNYVALE,CA
[2] STERLING WINTHROP PHARMACEUT RES DIV,NEW YORK,NY
关键词
HEART; EXPERIMENTAL STUDIES; MAGNETIC RESONANCE; PULSE SEQUENCES; CONTRAST ENHANCEMENT;
D O I
10.1148/radiology.190.1.8259398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To show the effect of dysprosium diethylenetriaminepentaacetic acid bis-methylamine injection on the images of normal human myocardium. MATERIALS AND METHODS: T2-sensitive fast gradient-recalled echo (GRE) (repetition lime [TR], 10.8 msec; echo time [TE], 4.2 msec) and spin-echo (SE) (TR, three RR intervals; TE, 60 msec) magnetic resonance (MR) imaging with driven equilibrium-preparation pulse was used to produce T2 contrast material enhancement. The contrast agent was injected into 12 healthy subjects at doses of 0.05, 0.1, 0.2, 0.4, and 0.6 mmol/kg. RESULTS: Driven equilibrium-prepared GRE images showed a transient decrease of myocardial signal intensity at doses of 0.2-0.6 mmol/kg. Postcontrast T2-weighted SE images showed a myocardial signal attenuation (30%-45% decrease) at a dose of 0.4 mmol/kg or higher. CONCLUSION: Dynamic MR imaging with a magnetic susceptibility contrast medium can be used to monitor the first pass of contrast media through human myocardium with a conventional MR imager and a fast GRE sequence.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [41] Fast Spin-Echo Triple-Echo Dixon: Initial Clinical Experience With A Novel Pulse Sequence for Fat-Suppressed T2-Weighted Abdominal MR Imaging
    Low, Russell N.
    Ma, Jingfei
    Panchal, Neeraj
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 569 - 577
  • [42] Fast T2 mapping of the patellar articular cartilage with gradient and spin-echo magnetic resonance imaging at 1.5 T: validation and initial clinical experience in patients with osteoarthritis
    Quaia, Emilio
    Toffanin, Renato
    Guglielmi, Giuseppe
    Ukmar, Maja
    Rossi, Alexia
    Martinelli, Bruno
    Cova, Maria Assunta
    SKELETAL RADIOLOGY, 2008, 37 (06) : 511 - 517
  • [43] Fast T2 mapping of the patellar articular cartilage with gradient and spin-echo magnetic resonance imaging at 1.5 T: validation and initial clinical experience in patients with osteoarthritis
    Emilio Quaia
    Renato Toffanin
    Giuseppe Guglielmi
    Maja Ukmar
    Alexia Rossi
    Bruno Martinelli
    Maria Assunta Cova
    Skeletal Radiology, 2008, 37 : 511 - 517
  • [44] Contrast-enhanced T1-weighted black-blood fast spin-echo MR imaging of the brain - Technique for suppression of enhancing venous signal
    Amano, Y
    Takagi, R
    Takahama, K
    Kumazaki, T
    ACTA RADIOLOGICA, 2001, 42 (01) : 27 - 32
  • [45] Inner ear volume measurements using high resolution three-dimensional heavily T2-weighted fast spin-echo MR imaging: Initial experience
    Melhem, ER
    Shakir, H
    Bakthavachalam, S
    Macdonald, BC
    Caruthers, S
    Jara, H
    RADIOLOGY, 1998, 209P : 423 - 423
  • [46] Liver lesion conspicuity: T2-weighted breath-hold fast spin-echo MR imaging before and after gadolinium enhancement-initial experience
    Jeong, YY
    Mitchell, DG
    Holland, GA
    RADIOLOGY, 2001, 219 (02) : 455 - 460
  • [47] Fast Spin-Echo Triple Echo Dixon: Initial Clinical Experience With a Novel Pulse Sequence for Simultaneous Fat-Suppressed and Nonfat-Suppressed T2-Weighted Spine Magnetic Resonance Imaging
    Low, Russell N.
    Austin, Matthew J.
    Ma, Jingfei
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (02) : 390 - 400
  • [48] MR IMAGING OF CEREBRAL BLOOD-FLOW - BASIC PRINCIPLES AND PRELIMINARY CLINICAL-EXPERIENCE WITH T2-ASTERISK-WEIGHTED GRADIENT ECHO IMAGES AND BOLUS APPLICATION OF CONTRAST-MEDIUM
    GUCKEL, F
    WENTZ, KU
    BRIX, G
    JASCHKE, W
    ROTHER, J
    LOOSE, R
    DEIMLING, M
    GEORGI, M
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (03): : 212 - 217
  • [49] Tumor-liver contrast and subjective tumor conspicuity of respiratory-triggered T2-weighted fast spin-echo sequence compared with T2-weighted gradient recalled-echo sequence for ferucarbotran-enhanced magnetic resonance imaging of hepatic malignant tumors
    Ishiyama, Koichi
    Hashimoto, Manabu
    Izumi, Jun-ichi
    Watarai, Jiro
    Shibata, Satoshi
    Sato, Tsutomu
    Yamamoto, Yuzo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1322 - 1326
  • [50] Inner ear volumetric measurements using high-resolution 3D T2-weighted fast spin-echo MR imaging: Initial experience in healthy subjects
    Melhem, ER
    Shakir, H
    Bakthavachalam, S
    MacDonald, CB
    Gira, J
    Caruthers, SD
    Jara, H
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (10) : 1819 - 1822