EFFECT OF MAGNETIC-SUSCEPTIBILITY CONTRAST-MEDIUM ON MYOCARDIAL SIGNAL INTENSITY WITH FAST GRADIENT-RECALLED ECHO AND SPIN-ECHO MR-IMAGING - INITIAL EXPERIENCE IN HUMANS

被引:19
|
作者
SAKUMA, H
OSULLIVAN, M
LUCAS, J
WENDLAND, MF
SAEED, M
DULCE, MC
WATSON, A
BLEYL, KL
LAFRANCE, ND
HIGGINS, CB
机构
[1] NYCOMED SALUTAR,SUNNYVALE,CA
[2] STERLING WINTHROP PHARMACEUT RES DIV,NEW YORK,NY
关键词
HEART; EXPERIMENTAL STUDIES; MAGNETIC RESONANCE; PULSE SEQUENCES; CONTRAST ENHANCEMENT;
D O I
10.1148/radiology.190.1.8259398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To show the effect of dysprosium diethylenetriaminepentaacetic acid bis-methylamine injection on the images of normal human myocardium. MATERIALS AND METHODS: T2-sensitive fast gradient-recalled echo (GRE) (repetition lime [TR], 10.8 msec; echo time [TE], 4.2 msec) and spin-echo (SE) (TR, three RR intervals; TE, 60 msec) magnetic resonance (MR) imaging with driven equilibrium-preparation pulse was used to produce T2 contrast material enhancement. The contrast agent was injected into 12 healthy subjects at doses of 0.05, 0.1, 0.2, 0.4, and 0.6 mmol/kg. RESULTS: Driven equilibrium-prepared GRE images showed a transient decrease of myocardial signal intensity at doses of 0.2-0.6 mmol/kg. Postcontrast T2-weighted SE images showed a myocardial signal attenuation (30%-45% decrease) at a dose of 0.4 mmol/kg or higher. CONCLUSION: Dynamic MR imaging with a magnetic susceptibility contrast medium can be used to monitor the first pass of contrast media through human myocardium with a conventional MR imager and a fast GRE sequence.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [21] Cerebral venous thrombus signal intensity and susceptibility effects on gradient recalled-echo MR imaging
    Leach, J. L.
    Strub, W. M.
    Gaskill-Shipley, M. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (05) : 940 - 945
  • [22] FAST SPIN-ECHO MR-IMAGING OF THE CERVICAL-SPINE - INFLUENCE OF ECHO TRAIN LENGTH AND ECHO SPACING ON IMAGE-CONTRAST AND QUALITY
    SZE, G
    KAWAMURA, Y
    NEGISHI, C
    CONSTABLE, RT
    MERRIAM, M
    OSHIO, K
    JOLESZ, F
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (05) : 1203 - 1213
  • [23] Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study
    Shi, Yu
    Xia, Fei
    Li, Qiu-ju
    Li, Jia-hui
    Yu, Bing
    Li, Yue
    An, He
    Glaser, Kevin J.
    Tao, Shengzhen
    Ehman, Richard L.
    Guo, Qi-yong
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2016, 111 (06): : 823 - 833
  • [24] DYNAMIC CONTRAST-ENHANCED MR-IMAGING OF THE PITUITARY-GLAND WITH FAST SPIN-ECHO TECHNIQUE
    DAVIS, WL
    LEE, JN
    KING, BD
    HARNSBERGER, HR
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 509 - 511
  • [25] Comparison of technical failure of MR elastography for measuring liver stiffness between gradient-recalled echo and spin-echo echo-planar imaging: A systematic review and meta-analysis
    Kim, Dong Wook
    Kim, So Yeon
    Yoon, Hee Mang
    Kim, Kyung Won
    Byun, Jae Ho
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (04) : 1086 - 1102
  • [26] MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements
    Chenyang Zhan
    Stephan Kannengiesser
    Hersh Chandarana
    Matthias Fenchel
    Justin Ream
    Krishna Prasad Shanbhogue
    Abdominal Radiology, 2019, 44 : 1825 - 1833
  • [27] MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements
    Zhan, Chenyang
    Kannengiesser, Stephan
    Chandarana, Hersh
    Fenchel, Matthias
    Ream, Justin
    Shanbhogue, Krishna Prasad
    ABDOMINAL RADIOLOGY, 2019, 44 (05) : 1825 - 1833
  • [28] MR-IMAGING OF THE NORMAL MENINGES - COMPARISON OF CONTRAST-ENHANCEMENT PATTERNS ON 3D GRADIENT-ECHO AND SPIN-ECHO IMAGES
    FARN, JW
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 131 - 135
  • [29] re: Comparison of Technical Failure of MR Elastography for Measuring Liver Stiffness Between Gradient-Recalled Echo and Spin-Echo Echo-Planar Imaging: A Systematic Review and Meta-Analysis
    Ehman, Richard L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (04) : 1103 - 1104
  • [30] Accuracy of liver fat quantification at MR imaging: Comparison of out-of-phase gradient-echo and fatsaturated fast spin-echo techniques - Initial experience
    Qayyum, A
    Goh, JS
    Kakar, S
    Yeh, BM
    Merriman, RB
    Coakley, FV
    RADIOLOGY, 2005, 237 (02) : 507 - 511