EFFECT OF MAGNETIC-SUSCEPTIBILITY CONTRAST-MEDIUM ON MYOCARDIAL SIGNAL INTENSITY WITH FAST GRADIENT-RECALLED ECHO AND SPIN-ECHO MR-IMAGING - INITIAL EXPERIENCE IN HUMANS

被引:19
|
作者
SAKUMA, H
OSULLIVAN, M
LUCAS, J
WENDLAND, MF
SAEED, M
DULCE, MC
WATSON, A
BLEYL, KL
LAFRANCE, ND
HIGGINS, CB
机构
[1] NYCOMED SALUTAR,SUNNYVALE,CA
[2] STERLING WINTHROP PHARMACEUT RES DIV,NEW YORK,NY
关键词
HEART; EXPERIMENTAL STUDIES; MAGNETIC RESONANCE; PULSE SEQUENCES; CONTRAST ENHANCEMENT;
D O I
10.1148/radiology.190.1.8259398
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To show the effect of dysprosium diethylenetriaminepentaacetic acid bis-methylamine injection on the images of normal human myocardium. MATERIALS AND METHODS: T2-sensitive fast gradient-recalled echo (GRE) (repetition lime [TR], 10.8 msec; echo time [TE], 4.2 msec) and spin-echo (SE) (TR, three RR intervals; TE, 60 msec) magnetic resonance (MR) imaging with driven equilibrium-preparation pulse was used to produce T2 contrast material enhancement. The contrast agent was injected into 12 healthy subjects at doses of 0.05, 0.1, 0.2, 0.4, and 0.6 mmol/kg. RESULTS: Driven equilibrium-prepared GRE images showed a transient decrease of myocardial signal intensity at doses of 0.2-0.6 mmol/kg. Postcontrast T2-weighted SE images showed a myocardial signal attenuation (30%-45% decrease) at a dose of 0.4 mmol/kg or higher. CONCLUSION: Dynamic MR imaging with a magnetic susceptibility contrast medium can be used to monitor the first pass of contrast media through human myocardium with a conventional MR imager and a fast GRE sequence.
引用
收藏
页码:161 / 166
页数:6
相关论文
共 50 条
  • [1] MAGNETIC-SUSCEPTIBILITY ARTIFACTS IN GRADIENT-RECALLED ECHO MR IMAGING
    CZERVIONKE, LF
    DANIELS, DL
    WEHRLI, FW
    MARK, LP
    HENDRIX, LE
    STRANDT, JA
    WILLIAMS, AL
    HAUGHTON, VM
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (06) : 1149 - 1155
  • [2] PREOPERATIVE EVALUATION OF INTRAABDOMINAL TUMORS IN CHILDREN - GRADIENT-RECALLED ECHO VS SPIN-ECHO MR-IMAGING
    SHADY, KL
    SIEGEL, MJ
    BROWN, JJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (04) : 843 - 847
  • [3] MR-IMAGING OF PERITONEAL DISEASE - COMPARISON OF CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED AND SPIN-ECHO IMAGING
    LOW, RN
    SIGETI, JS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (05) : 1131 - 1140
  • [4] EVALUATION OF MALIGNANT BILIARY OBSTRUCTION - EFFICACY OF FAST MULTIPLANAR SPOILED GRADIENT-RECALLED MR-IMAGING VS SPIN-ECHO MR-IMAGING, CT, AND CHOLANGIOGRAPHY
    LOW, RN
    SIGETI, JS
    FRANCIS, IR
    WEINMAN, D
    BOWER, B
    SHIMAKAWA, A
    FOO, TKF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (02) : 315 - 323
  • [5] FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING OF THE LIVER - PULSE SEQUENCE OPTIMIZATION AND COMPARISON WITH SPIN-ECHO MR IMAGING
    LOW, RN
    FRANCIS, IR
    HERFKENS, RJ
    JEFFREY, RB
    GLAZER, GM
    FOO, TKF
    SHIMAKAWA, A
    PELC, NJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 501 - 509
  • [6] HEAD AND NECK - INITIAL CLINICAL-EXPERIENCE WITH FAST SPIN-ECHO MR-IMAGING
    ZOARSKI, GH
    MACKEY, JK
    ANZAI, Y
    HANAFEE, WN
    MELKI, PS
    MULKERN, RV
    JOLESZ, FA
    LUFKIN, RB
    RADIOLOGY, 1993, 188 (02) : 323 - 327
  • [7] MUSCULOSKELETAL MR-IMAGING - TURBO (FAST) SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO AND GRADIENT-ECHO IMAGING AT 0.5-TESLA
    VAHLENSIECK, M
    LANG, P
    SEELOS, K
    SZE, DYH
    GRAMPP, S
    REISER, M
    SKELETAL RADIOLOGY, 1994, 23 (08) : 607 - 610
  • [8] Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis
    Yong Seek Kim
    Yu Na Jang
    Ji Soo Song
    European Radiology, 2018, 28 : 1709 - 1718
  • [9] DEMARCATION OF MYOCARDIAL ISCHEMIA - MAGNETIC-SUSCEPTIBILITY EFFECT OF CONTRAST-MEDIUM IN MR IMAGING
    SAEED, M
    WENDLAND, MF
    TOMEI, E
    ROCKLAGE, SM
    QUAY, SC
    MOSELEY, ME
    WOLFE, C
    HIGGINS, CB
    RADIOLOGY, 1989, 173 (03) : 763 - 767
  • [10] Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis
    Kim, Yong Seek
    Jang, Yu Na
    Song, Ji Soo
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1709 - 1718