RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER

被引:0
|
作者
Alfuth, Martin [1 ,2 ]
Murielle, Magali [2 ]
机构
[1] Niederrhein Univ Appl Sci, Fac Hlth Care, Therapeut Sci, Reinarzstr 49, D-47805 Krefeld, Germany
[2] German Sport Univ Cologne, Dept Further Educ, MSc Sport Physiotherapy, Sportpk Mungersdorf 6, D-50933 Cologne, Germany
来源
关键词
different test positions; dynamometry; eversion; inversion; reproducibility;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: There are conflicting results with respect to the validity and reliability of lower extremity strength measurements using a hand-held dynamometer (HHD) in the healthy population. Previous studies exploring foot inversion and eversion strength using a HHD were carried out with predominantly clinically affected participants in different positions. The question arises whether HHD measurements of isometric foot inversion and eversion strength performed with participants in different positions are valid, reliable and comparable and can be used alternatively. Purpose: The aims of this study were to investigate: a) the intra-and inter-tester reliability of measurements of foot inversion and eversion strength in different participant positions using a belt-stabilized HHD; b) the comparability of results obtained in different positions; and c) the concurrent validity of the aforementioned measurements using an isokinetic dynamometer. Methods: Thirty adults (12 females and 18 males; mean age 22.5 +/- 3.9 years) volunteered to participate in this study. Maximal isometric foot inversion and eversion torques (Nm) were measured with participants lying supine, sitting with knees extended and lying on their side using a belt-stabilized HHD. Measurements were performed independently by two physiotherapists over two days and were repeated using an isokinetic dynamometer. Validity and intra-and inter-tester reliability were determined using the intra-class correlation coefficient (ICC). A two-way ANOVA (p<0.05) and post-hoc tests with Bonferroni correction were used to compare data from different positions. Bland-Altman plots were used to demonstrate the range of error and difference between HHD and isokinetic measurements. Results: Intra-tester reliability for inversion and eversion torques was fair to excellent in all positions (ICC=0.598-0.828). Excellent inter-tester reliability was found for eversion torques in all positions (ICC=0.773-0.860). For inversion torques, inter-tester reliability was fair to excellent (ICC=0.519-0.879). ICC values of 0.205 to 0.562 indicated a low to fair concurrent validity. A significant difference was observed between the torques of the supine and side-lying positions as well as sitting and side-lying positions (p<0.05). Bland-Altman plots showed that the mean of the differences for inversion and eversion torques deviates considerably from zero, indicating that measurements with the HHD in the three positions produce lower values compared to using the isokinetic dynamometer. Conclusions: Inversion and eversion strength measurements with subjects in different positions using HHD seem to be reliable, but consistently underestimated torque output when compared with measurements using isokinetic dynamometry. While the HHD outcomes measured in supine and sitting positions seem to be comparable, those measured in supine/sitting and side-lying positions differed.
引用
收藏
页码:72 / 84
页数:13
相关论文
共 50 条
  • [11] Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
    Suzuki, Terumi
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 967 - 971
  • [12] HAND-HELD DYNAMOMETER POSITIONING IMPACTS DISCOMFORT DURING QUADRICEPS STRENGTH TESTING: A VALIDITY AND RELIABILITY STUDY
    Hansen, Evan M.
    McCartney, Caitlyn N.
    Sweeney, Ryan S.
    Palimenio, Marcus R.
    Grindstaff, Terry L.
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2015, 10 (01): : 62 - 68
  • [13] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER APPLIED TO ADULTS WITH MENTAL-RETARDATION
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (06): : 535 - 539
  • [14] Strength assessment in postpolio syndrome: Validity of a hand-held dynamometer in detecting change
    Nollet, F
    Beelen, A
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (10): : 1316 - 1323
  • [15] Comparison of Reliability of Isometric Leg Muscle Strength Measurements Made Using a Hand-Held Dynamometer with and without a Restraining Belt
    Katoh, Munenori
    Yamasaki, Hiroshi
    [J]. JOURNAL OF PHYSICAL THERAPY SCIENCE, 2009, 21 (01) : 37 - 42
  • [16] Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength
    Cadogan, Angela
    Laslett, Mark
    Hing, Wayne
    McNair, Peter
    Williams, Maynard
    [J]. MANUAL THERAPY, 2011, 16 (01) : 97 - 101
  • [17] INTRATESTER RELIABILITY OF STRENGTH TESTING IN DYSTROPHIC AND NORMAL-CHILDREN USING A HAND-HELD DYNAMOMETER
    STUBERG, WA
    METCALF, WK
    [J]. PHYSICAL THERAPY, 1986, 66 (05): : 800 - 800
  • [18] Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength
    Jubany, Julia
    Busquets, Albert
    Marina, Michel
    Cos, Francesc
    Angulo-Barroso, Rosa
    [J]. JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2015, 28 (02) : 317 - 326
  • [19] RELIABILITY OF MUSCLE STRENGTH MEASURES OBTAINED WITH A HAND-HELD DYNAMOMETER IN AN ELDERLY POPULATION
    Buckinx, F.
    Croisier, J. L.
    Reginster, J. -Y.
    Dardenne, N.
    Beaudart, C.
    Slomian, J.
    Bruyere, O.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S161 - S161
  • [20] Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population
    Buckinx, Fanny
    Croisier, Jean-Louis
    Reginster, Jean-Yves
    Dardenne, Nadia
    Beaudart, Charlotte
    Slomian, Justine
    Leonard, Sylvain
    Bruyere, Olivier
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 332 - 340