Research of complete loss of flow accident for AP1000 based on RELAP5 code

被引:2
|
作者
Jing, Jianping [1 ]
Sun, Wei [1 ]
Huang, Xuyang [1 ]
Qiao, Xuedong [1 ]
机构
[1] Nucl & Radiat Safety Ctr, Beijing 100082, Peoples R China
关键词
RELAP5/MOD; 3.3; code; AP1000; CLOFA; LOFTRAN code;
D O I
10.3233/JCM-150536
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
AP1000 reactor is the typical "third-generation" nuclear power plant in the world at present. The primary system of AP1000 nuclear power plant was modeled using RELAP5/MOD 3.3 code, and the transient thermal hydraulic characteristics were analyzed under complete loss of flow accident (CLOFA). The calculation results by RELAP5 code were compared with those of the LOFTRAN codes. The research results show that the RELAP5 model can accurately simulate the transient thermal hydraulic characteristics of AP1000 under the accident of complete loss of forced reactor coolant flow. Meanwhile, comparison was made between the results of complete loss of reactor coolant flow initiated by loss of voltage and frequency reduction of offsite power, and the analysis indicates that the results of complete loss of flow initiated by complete loss of voltage bound the complete loss of flow initiated by reduction in the reactor coolant pump motor supply frequency with a frequency decay of up to 5 hertz per second.
引用
收藏
页码:229 / 239
页数:11
相关论文
共 50 条
  • [41] The Investigation of Nonavailability of Passive Safety Systems Effects on Small Break LOCA Sequence in AP1000 Using RELAP5 MOD 4.0
    Hussain, Anwar
    Nawaz, Amjad
    [J]. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2016, 2016
  • [42] EVALUATION OF THE RELAP5/SCDAP ACCIDENT ANALYSIS CODE APPLICABILITY TO CANDU NUCLEAR REACTORS
    Mladin, Mirea
    Dupleac, Daniel
    Prisecaru, Ilie
    [J]. UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2009, 71 (04): : 143 - 156
  • [43] Development of ocean-condition code based on RELAP5
    Tan, Chang-Lu
    Zhang, Hong
    Zhao, Hua
    [J]. Hedongli Gongcheng/Nuclear Power Engineering, 2009, 30 (06): : 53 - 56
  • [44] Accident safety analysis of flow blockage in an assembly in the JRR-3M research reactor using system code RELAP5 and CFD code FLUENT
    Guo, Yuchuan
    Wang, Guanbo
    Qian, Dazhi
    Yu, Heng
    Hu, Bo
    Guo, Simao
    Mi, Xiangmiao
    Ma, Jimin
    [J]. ANNALS OF NUCLEAR ENERGY, 2018, 122 : 125 - 136
  • [45] Research on the steam-gas pressurizer model with Relap5 code
    Ma, Xi-Zhen
    Jia, Hai-Jun
    Liu, Yang
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (05)
  • [46] MARIA Research Reactor Thermalhydraulic Calculations With RELAP5 Code.
    Skrzypek, Eleonora
    Skrzypek, Maciej
    Gomulski, Krzysztof
    [J]. 23RD INTERNATIONAL CONFERENCE NUCLEAR ENERGY FOR NEW EUROPE, (NENE 2014), 2014,
  • [47] Simulation of the AP1000 reactor containment pressurization during loss of coolant accident
    Rahim, Farzad Choobdar
    Yousefi, Pooria
    Aliakbari, Elnaz
    [J]. PROGRESS IN NUCLEAR ENERGY, 2012, 60 : 129 - 134
  • [48] Simulation and Analysis of Small Break LOCA for AP1000 Using RELAP5-MV and Its Comparison with NOTRUMP Code
    Yousif, Eltayeb
    Zhang, Zhijian
    Tian, Zhaofei
    Ju, Hao-ran
    [J]. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2017, 2017
  • [49] Simulation of Small-Break Loss-of-Coolant Accident Using the RELAP5 Code with an Improved Wall Drag Partition Model for Bubbly Flow
    Lee, Young Hwan
    Ryu, Nam Kyu
    Kim, Byoung Jae
    [J]. Energies, 2024, 17 (22)
  • [50] Investigation on two-phase flow instability in parallel channels based on RELAP5 code
    Xia, Geng-Lei
    Guo, Yun
    Peng, Min-Jun
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (06): : 694 - 700