RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY USING A MODIFIED INOUE BALLOON CATHETER

被引:14
|
作者
STEFANADIS, C
STRATOS, C
KALLIKAZAROS, I
TSIAMIS, E
VLACHOPOULOS, C
SIDERIS, A
TOUTOUZAS, CP
TOUTOUZAS, P
机构
[1] Department of Cardiology, Hippokration Hospital, University of Athens, Athens
来源
关键词
MITRAL STENOSIS; VALVULOPLASTY;
D O I
10.1002/ccd.1810330307
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Retrograde nontransseptal balloon mitral valvuloplasty, a method developed in our institution for the treatment of symptomatic mitral stenosis, avoids transseptal catheterization. Until recently, the self-positioning Inoue balloon catheter, unlike all other commercially available balloon catheters, had not been employed in this nontransseptal technique due to the short length of its catheter shaft. To employ a self-positioning balloon in retrograde nontransseptal balloon mitral valvuloplasty, we modified the Inoue device by extension of the catheter shaft. After retrograde nontransseptal left atrial catheterization using a steerable cardiac catheter, the modified Inoue balloon catheter was inserted through the femoral artery and advanced to the mitral valve retrogradely. Valvuloplasty was performed in 20 patients, with a successful result achieved in all. The modified Inoue balloon catheter was easy to use in retrograde nontransseptal balloon mitral valvuloplasty and showed excellent stability during inflation. Mean mitral valve area increased from 1.0 +/- 0.29 to 2.23 +/- 0.64 cm(2) (P<0.001) and mean transmitral gradient decreased from 11.4 +/- 6 to 4.3 +/- 2.1 mm Hg (P<0.001). No major or minor complications were observed. Retrograde nontransseptal balloon mitral valvuloplasty using a modified Inoue balloon catheter is a feasible and effective technique for the treatment of symtomatic mitral stenosis. It appears to combine the advantages of avoiding transseptal catheterization with the advantages of this balloon's special configuration. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:224 / 233
页数:10
相关论文
共 50 条
  • [41] The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis
    Naoko Yuzawa-Tsukada
    Yusuke Kashiwagi
    Akira Nonoue
    Goki Uno
    Shinya Fujii
    Akimichi Murakami
    Kazuo Ogawa
    Makoto Kawai
    Makoto Muto
    Michihiro Yoshimura
    Takashi Miyamoto
    [J]. Heart and Vessels, 2022, 37 : 2093 - 2100
  • [42] The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis
    Yuzawa-Tsukada, Naoko
    Kashiwagi, Yusuke
    Nonoue, Akira
    Uno, Goki
    Fujii, Shinya
    Murakami, Akimichi
    Ogawa, Kazuo
    Kawai, Makoto
    Muto, Makoto
    Yoshimura, Michihiro
    Miyamoto, Takashi
    [J]. HEART AND VESSELS, 2022, 37 (12) : 2093 - 2100
  • [43] PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY USING THE INOUE BALLOON CATHETER
    INOUE, K
    FELDMAN, T
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 28 (02): : 119 - 125
  • [44] ATRIAL SEPTAL PUNCTURE TECHNIQUE IN PERCUTANEOUS TRANSVENOUS MITRAL COMMISSUROTOMY - MITRAL VALVULOPLASTY USING THE INOUE BALLOON CATHETER TECHNIQUE
    HUNG, JS
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (04): : 275 - 284
  • [45] A novel "proximal first" Inoue balloon catheter for retrograde aortic valvuloplasty: Initial case report
    Onishi, Takayuki
    Fukutomi, Motoki
    Ando, Tomo
    Tobaru, Tetsuya
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (07) : 2131 - 2135
  • [46] Inoue balloon versus monofoil balloon in mitral valvuloplasty. Results and complications.
    Peixoto, E
    Oliveira, P
    Salles, M
    Borges, I
    Sena, M
    Peixoto, R
    Labrunie, P
    Villela, R
    Labrunie, M
    Neves, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TC264 - TC264
  • [47] PERCUTANEOUS MITRAL VALVULOPLASTY WITH THE INOUE-BALLOON IN ELDERLY PATIENTS
    SEGGEISS, H
    SCHMIDT, HK
    FASSBENDER, D
    TERWESTEN, HP
    MANNEBACH, H
    GLEICHMANN, U
    [J]. CIRCULATION, 1994, 90 (04) : 64 - 64
  • [48] PERCUTANEOUS MITRAL VALVULOPLASTY WITH THE INOUE BALLOON - CASE-REPORT
    FLORENZANO, F
    KAUFFMANN, R
    URIARTE, P
    HERNANDEZ, MV
    [J]. REVISTA MEDICA DE CHILE, 1991, 119 (04) : 431 - 435
  • [49] Comparison of results and complications with Inoue balloon and single balloon technics in mitral valvuloplasty.
    Peixoto, ECS
    Oliveira, PS
    Netto, MS
    Borges, IP
    Peixoto, RTS
    Labrunie, P
    Villela, RA
    Labrunie, M
    Burello, DM
    Brito, GAX
    Peixoto, RTS
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (6A): : 122P - 122P
  • [50] Learning curve of the Inoue technique of percutaneous mitral balloon valvuloplasty
    Palacios, IF
    Sanchez, PL
    Harrell, LC
    Salas, RE
    [J]. CIRCULATION, 2001, 104 (17) : 581 - 582