A novel "proximal first" Inoue balloon catheter for retrograde aortic valvuloplasty: Initial case report

被引:0
|
作者
Onishi, Takayuki [1 ]
Fukutomi, Motoki [1 ]
Ando, Tomo [1 ]
Tobaru, Tetsuya [1 ]
机构
[1] Kawasaki Saiwai Hosp, Kawasaki Heart Ctr, Dept Cardiol, Kawasaki, Kanagawa, Japan
关键词
a novel Inoue balloon catheter; retrograde aortic valvuloplasty; VALVE AREA; IMPROVEMENT; STENOSIS;
D O I
10.1002/ccd.30166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Inoue balloon, invented for percutaneous transseptal mitral commissurotomy for mitral stenosis, is initially dilated in the distal portion and then the proximal portion, forming an hourglass shape that stabilizes the balloon at the mitral valve orifice with a pulling action. The device has been successfully applied to antegrade aortic valvuloplasty; the hourglass shape stabilizes the balloon across the aortic valve without rapid ventricular pacing. Subsequently, an Inoue balloon was developed for retrograde aortic valvuloplasty using the same design as the antegrade balloon. The hourglass-shaped balloon, however, has difficulty maintaining stability across the aortic valve because the distal portion of the balloon, which inflates first, directly receives systolic pressure from the left ventricle. A novel Inoue balloon was invented to overcome this issue by altering the manner of inflation: the proximal portion inflates first, followed by the distal portion. Theoretically, the proximal portion, which initially inflates just above the aortic valve, remains secure across the valve by applying a pressing force that counteracts the systolic forward pressure. Furthermore, a radiopaque marker is placed at the center of the balloon to enable rapid and precise balloon adjustment. We present a case involving a 65-year-old female hemodialysis patient with severe symptomatic aortic stenosis who we successfully treated with balloon aortic valvuloplasty using the novel Inoue balloon followed by transcatheter aortic valve implantation. The present case demonstrates the feasibility and effectiveness of the novel "proximal first" Inoue balloon for retrograde balloon aortic valvuloplasty for severe aortic stenosis.
引用
收藏
页码:2131 / 2135
页数:5
相关论文
共 50 条
  • [1] RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY USING THE INOUE BALLOON CATHETER
    STEFANADIS, C
    STRATOS, C
    KALLIKAZAROS, I
    TSIAMIS, E
    VLACHOPOULOS, C
    SIDERIS, A
    TOUTOUZAS, C
    TOUTOUZAS, P
    [J]. CIRCULATION, 1994, 90 (04) : 64 - 64
  • [2] Retrograde balloon aortic valvuloplasty with the newly invented Inoue balloon for aortic stenosis accompanied by severe heart failure: A case report
    Ishizu, Kenichi
    Kawaguchi, Tomohiro
    Shirai, Shinichi
    Ando, Kenji
    [J]. CLINICAL CASE REPORTS, 2021, 9 (04): : 2011 - 2015
  • [3] RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY USING A MODIFIED INOUE BALLOON CATHETER
    STEFANADIS, C
    STRATOS, C
    KALLIKAZAROS, I
    TSIAMIS, E
    VLACHOPOULOS, C
    SIDERIS, A
    TOUTOUZAS, CP
    TOUTOUZAS, P
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (03): : 224 - 233
  • [4] The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis
    Naoko Yuzawa-Tsukada
    Yusuke Kashiwagi
    Akira Nonoue
    Goki Uno
    Shinya Fujii
    Akimichi Murakami
    Kazuo Ogawa
    Makoto Kawai
    Makoto Muto
    Michihiro Yoshimura
    Takashi Miyamoto
    [J]. Heart and Vessels, 2022, 37 : 2093 - 2100
  • [5] The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis
    Yuzawa-Tsukada, Naoko
    Kashiwagi, Yusuke
    Nonoue, Akira
    Uno, Goki
    Fujii, Shinya
    Murakami, Akimichi
    Ogawa, Kazuo
    Kawai, Makoto
    Muto, Makoto
    Yoshimura, Michihiro
    Miyamoto, Takashi
    [J]. HEART AND VESSELS, 2022, 37 (12) : 2093 - 2100
  • [6] PULMONARY VALVULOPLASTY USING INOUE BALLOON CATHETER
    BAHI, VK
    CHANDRA, S
    WASIR, HS
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1994, 45 (02) : 141 - 143
  • [7] Stepwise Inoue balloon catheter valvuloplasty for congenital aortic valve stenosis: Comparison with standard balloon catheter technique
    Ruzyllo, W
    Demkow, M
    Ksiezycka, E
    Ciszewski, M
    Szaroszyk, W
    [J]. PEDIATRIC CARDIOLOGY, 1996, 17 (01) : 15 - 20
  • [8] PERCUTANEOUS MITRAL VALVULOPLASTY WITH THE INOUE BALLOON - CASE-REPORT
    FLORENZANO, F
    KAUFFMANN, R
    URIARTE, P
    HERNANDEZ, MV
    [J]. REVISTA MEDICA DE CHILE, 1991, 119 (04) : 431 - 435
  • [9] PULMONARY VALVULOPLASTY IN ADULTS USING THE INOUE BALLOON CATHETER
    LAU, KW
    HUNG, JS
    WU, JJ
    CHERN, MS
    YEH, KH
    FU, M
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (02): : 99 - 104
  • [10] Pulmonary Valvuloplasty in Adults Using the Inoue Balloon Catheter
    Pham, Hung Manh
    Nguyen, Hieu Lan
    Nguyen, Quang Ngoc
    Nguyen, Hung Minh
    Khong, Huong Nam
    Do, Loi Doan
    Nguyen, Viet Lan
    Pham, Khai Gia
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A97 - A97