RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY USING A MODIFIED INOUE BALLOON CATHETER

被引:14
|
作者
STEFANADIS, C
STRATOS, C
KALLIKAZAROS, I
TSIAMIS, E
VLACHOPOULOS, C
SIDERIS, A
TOUTOUZAS, CP
TOUTOUZAS, P
机构
[1] Department of Cardiology, Hippokration Hospital, University of Athens, Athens
来源
关键词
MITRAL STENOSIS; VALVULOPLASTY;
D O I
10.1002/ccd.1810330307
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Retrograde nontransseptal balloon mitral valvuloplasty, a method developed in our institution for the treatment of symptomatic mitral stenosis, avoids transseptal catheterization. Until recently, the self-positioning Inoue balloon catheter, unlike all other commercially available balloon catheters, had not been employed in this nontransseptal technique due to the short length of its catheter shaft. To employ a self-positioning balloon in retrograde nontransseptal balloon mitral valvuloplasty, we modified the Inoue device by extension of the catheter shaft. After retrograde nontransseptal left atrial catheterization using a steerable cardiac catheter, the modified Inoue balloon catheter was inserted through the femoral artery and advanced to the mitral valve retrogradely. Valvuloplasty was performed in 20 patients, with a successful result achieved in all. The modified Inoue balloon catheter was easy to use in retrograde nontransseptal balloon mitral valvuloplasty and showed excellent stability during inflation. Mean mitral valve area increased from 1.0 +/- 0.29 to 2.23 +/- 0.64 cm(2) (P<0.001) and mean transmitral gradient decreased from 11.4 +/- 6 to 4.3 +/- 2.1 mm Hg (P<0.001). No major or minor complications were observed. Retrograde nontransseptal balloon mitral valvuloplasty using a modified Inoue balloon catheter is a feasible and effective technique for the treatment of symtomatic mitral stenosis. It appears to combine the advantages of avoiding transseptal catheterization with the advantages of this balloon's special configuration. (C) 1994 Wiley-Liss, Inc.
引用
收藏
页码:224 / 233
页数:10
相关论文
共 50 条
  • [1] RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY USING THE INOUE BALLOON CATHETER
    STEFANADIS, C
    STRATOS, C
    KALLIKAZAROS, I
    TSIAMIS, E
    VLACHOPOULOS, C
    SIDERIS, A
    TOUTOUZAS, C
    TOUTOUZAS, P
    [J]. CIRCULATION, 1994, 90 (04) : 64 - 64
  • [2] Accomplishments and perspectives with retrograde nontransseptal balloon mitral valvuloplasty
    Stefanadis, CI
    Stratos, CG
    Lambrou, SG
    Toutouzas, PK
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2000, 13 (04) : 269 - 280
  • [3] ACUTE COMPLICATIONS AFTER RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY
    STEFANADIS, C
    STRATOS, C
    KALLIKAZAROS, I
    TSIAMIS, E
    VLACHOPOULOS, C
    FOUSSAS, S
    SIDERIS, A
    TOUTOUZAS, P
    [J]. CIRCULATION, 1993, 88 (04) : 351 - 351
  • [4] RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY FOR RHEUMATIC MITRAL-STENOSIS
    BAHL, VK
    JUNEJA, R
    THATAI, D
    KAUL, U
    SHARMA, S
    WASIR, HS
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 33 (04): : 331 - 334
  • [5] RETROGRADE NONTRANSSEPTAL BALLOON MITRAL VALVULOPLASTY - THE FIRST MULTICENTER EXPERIENCE
    STEFANADIS, C
    STRATOS, C
    BAHL, VK
    WASIR, HS
    VOUDRIS, V
    FOUSSAS, S
    COKKINOS, D
    TOUTOUZAS, P
    [J]. CIRCULATION, 1995, 92 (08) : 2947 - 2947
  • [6] Retrograde nontransseptal balloon mitral valvuloplasty by the brachial artery approach
    Stefanadis, CI
    Stratos, CG
    Lambrou, SG
    Toutouzas, PK
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 51 (01) : 101 - 106
  • [7] MITRAL VALVULOPLASTY WITH THE INOUE BALLOON
    HELLMULLER, B
    KAUFMANN, U
    MEIER, B
    [J]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 125 (44) : 2122 - 2130
  • [8] Retrograde nontransseptal balloon mitral valvuloplasty: Predictors for successful immediate outcome
    Stratos, C
    Stefanadis, C
    Lambrou, S
    Tsioufis, C
    Tsiamis, E
    Sideris, A
    Toutouzas, K
    Kalikazaros, I
    Toutouzas, PK
    [J]. CIRCULATION, 1997, 96 (08) : 2220 - 2220
  • [9] Update on cardiac and vascular safety of retrograde nontransseptal balloon mitral valvuloplasty
    Lambrou, SG
    Stratos, C
    Aggeli, C
    Sideris, A
    Pitsavos, C
    Stefanadis, C
    Toutouzas, P
    [J]. EUROPEAN HEART JOURNAL, 2001, 22 : 629 - +
  • [10] PULMONARY VALVULOPLASTY USING INOUE BALLOON CATHETER
    BAHI, VK
    CHANDRA, S
    WASIR, HS
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1994, 45 (02) : 141 - 143