Intracranial Pressure Monitoring: Invasive versus Non-Invasive Methods-A Review

被引:260
|
作者
Raboel, P. H. [1 ]
Bartek, J., Jr. [1 ,2 ]
Andresen, M. [1 ]
Bellander, B. M. [2 ]
Romner, B. [1 ]
机构
[1] Univ Copenhagen Hosp, Rigshosp, Dept Neurosurg, DK-2100 Copenhagen, Denmark
[2] Karolinska Univ Hosp, Dept Neurosurg, SE-17176 Stockholm, Sweden
关键词
D O I
10.1155/2012/950393
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Monitoring of intracranial pressure (ICP) has been used for decades in the fields of neurosurgery and neurology. There are multiple techniques: invasive as well as noninvasive. This paper aims to provide an overview of the advantages and disadvantages of the most common and well-known methods as well as assess whether noninvasive techniques (transcranial Doppler, tympanic membrane displacement, optic nerve sheath diameter, CT scan/MRI and fundoscopy) can be used as reliable alternatives to the invasive techniques (ventriculostomy and microtransducers). Ventriculostomy is considered the gold standard in terms of accurate measurement of pressure, although microtransducers generally are just as accurate. Both invasive techniques are associated with a minor risk of complications such as hemorrhage and infection. Furthermore, zero drift is a problem with selected microtransducers. The non-invasive techniques are without the invasive methods' risk of complication, but fail to measure ICP accurately enough to be used as routine alternatives to invasive measurement. We conclude that invasive measurement is currently the only option for accurate measurement of ICP.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Non-invasive monitoring of intracranial pressure changes: healthy volunteers study
    Roldan, Maria
    Bradley, George R. E.
    Mejia-Mejia, Elisa
    Abay, Tomas Y.
    Kyriacou, Panayiotis A.
    [J]. FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [22] NON-INVASIVE MONITORING OF INTRACRANIAL-PRESSURE BY TYMPANIC MEMBRANE DISPLACEMENT
    REID, A
    [J]. ZEITSCHRIFT FUR KINDERCHIRURGIE-SURGERY IN INFANCY AND CHILDHOOD, 1989, 44 : 31 - 31
  • [23] Non-invasive intracranial pulse wave monitoring
    Ragauskas, Arminas
    Daubaris, Gediminas
    Petkus, Vytautas
    Chomskis, Romanas
    Raisutis, Renaldas
    Deksnys, Vytautas
    Guzaitis, Jonas
    Lengvinas, Gintautas
    Matijosaitis, Vaidas
    [J]. INFORMATICA, 2008, 19 (03) : 391 - 402
  • [24] Non-Invasive Intracranial Pressure Methods during Pneumoperitoneum in an Animal Model
    Dip, Fernando
    Nguyen, David
    Lomenzo, Emanuele
    Szomstein, Samuel
    Szetter, Eugenia
    Rosenthal, Raul J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2014, 219 (03) : S62 - S63
  • [25] Accuracy of non-invasive intracranial pressure measurement
    Seddighi, Amir Saied
    Zadeh, Alireza Moqareh
    Seddighi, Afsoun
    Zali, Alireza
    [J]. CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2012, 7 (02): : 169 - 175
  • [26] Non-invasive assessment of intracranial pressure dynamics
    Aaslid, R.
    [J]. CEREBROVASCULAR DISEASES, 2013, 35 : 6 - 6
  • [27] NON-INVASIVE DIGITAL PRESSURE MONITORING
    MELENDEZ, J
    WEISSMAN, C
    DELPHIN, E
    DODDS, T
    WALD, A
    [J]. CRITICAL CARE MEDICINE, 1988, 16 (04) : 427 - 427
  • [28] Neuromodulation of OCD: A review of invasive and non-invasive methods
    Kammen, Alexandra
    Cavaleri, Jonathon
    Lam, Jordan
    Frank, Adam C.
    Mason, Xenos
    Choi, Wooseong
    Penn, Marisa
    Brasfield, Kaevon
    Van Noppen, Barbara
    Murray, Stuart B.
    Lee, Darrin Jason
    [J]. FRONTIERS IN NEUROLOGY, 2022, 13
  • [29] INVASIVE OR NON-INVASIVE MONITORING
    HUGENHOL.PG
    HEIKKILA, J
    HAGEMEIJ.F
    ARNTZENI.AC
    POOL, J
    PALADINO, D
    [J]. CIRCULATION, 1972, 46 (04) : 75 - &
  • [30] Review of non-invasive intracranial pressure measurement techniques for ophthalmology applications
    Price, David Andrew
    Grzybowski, Andrzej
    Eikenberry, Jennifer
    Januleviciene, Ingrida
    Verticchio Vercellin, Alice Chandra
    Mathew, Sunu
    Siesky, Brent
    Harris, Alon
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (07) : 887 - 892