The Measurement of Intraocular Pressure in Eyes with Keratoconus Using Pascal Dynamic Contour Tonometer

被引:0
|
作者
Ocakoglu, Ozcan [1 ]
Iskeleli, Guzin [1 ]
Ucar, Didar [1 ]
机构
[1] Istanbul Univ, Cerrahpafla Tip Fak, Goz Hastaliklari Ana Bilim Dali, Istanbul, Turkey
关键词
Keratoconus; Pascal dynamic contour tonometry; central corneal thickness;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare Pascal dynamic contour tonometer (DCT) with other tonometric systems for measurement of intraocular pressure (IOP) in eyes with keratoconus which has thinned cornea and topographically indicated keratoconus pattern and to investigate whether central corneal thickness (CCT) affect IOP measurements or not. Material and Method: Our study included 44 eyes of 28 patients which were diagnosed as keratoconus clinically and topographically. Their central corneal thicknesses which were measured with ultrasonographic pachymeter were under 500 microns (mu). IOP's were estimated using Pascal DCT, Goldmann applanation tonometer (GAT) and non contact air-puff tonometer (NCT). The "mean" IOP accepted as the mean of three consecutive measurements in different times. The "mean" IOP's values using Pascal DCT, GAT and NCT compared with paired student t test with each other. Statistically significance limit was p< 0,05. Pearson correlation analysis was used to determine the effect of CCT on IOP. Correlation coefficient was accepted r> 0,25 (p< 0,05). Results: The mean age of 28 patients with keratoconus was 30,18 +/- 8.8 years. In 44 study eyes, the mean value of CCT's was 465,8 +/- 24,1 mu. The mean values of IOP's using Pascal DCT, GAT and NCT were 14,3 +/- 2,3 mmHg, 11,1 +/- 2,6 mmHg, 8,11 +/- 1,9 mmHg, respectively. The mean IOP using Pascal DCT was statistically higher than the mean values of GAT and NCT (Student t test; p< 0,05). IOP measured with NCT were significantly correlated with CCT (Pearson correlation analysis r1= 0,26, p< 0,05) but IOP measured with GAT and Pascal DCT were not effected (for GAT r(2)= 0,09; for DKT r3= 0,06, p> 0,05). Conclusion: In eyes with keratoconus, the highest IOP value was measured with Pascal DCT. The measured IOP's using NCT was affected by the changes in CCT but the IOP's measured with Pascal DCT and GAT were not. When the technical problems with using GAT in eyes with keratoconus which was thinned and topographically distrurbed cornea are considered, we thought that to use Pascal DCT is more accurate and safely.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [41] MEASUREMENT OF INTRAOCULAR-PRESSURE WITH A PNEUMATIC APPLANATION TONOMETER
    WEST, CE
    CAPELLA, JA
    KAUFMAN, HE
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1972, 74 (03) : 505 - &
  • [42] Intraocular Pressure Measurement with Pneumatonometry and a Tonometer Tip Cover
    Ferguson, Tanner J.
    Knier, Catherine G.
    Chowdhury, Uttio Roy
    Monson, Kjerseten J.
    Greenwood, Michael
    Swan, Russell J.
    Gorham, Richard
    Berdahl, John P.
    Fautsch, Michael P.
    OPHTHALMOLOGY AND THERAPY, 2020, 9 (01) : 127 - 137
  • [43] Comparison of Intraocular Pressures After Photorefractive Keratectomy Using the Perkins Tonometer, Dynamic Contour Tonometer, Pneumatonometer, and the Tono-Pen
    Drayna, P. M.
    Neuffer, M. C.
    Panday, V. A.
    Reilly, C. D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [44] Calibration of the TonoVet Plus® tonometer to measure intraocular pressure in porcine eyes
    Chae, Jeremy
    Mills, Patrick O.
    Walker, Antwan
    Curry, Bishop
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [45] Assessment of Pascal dynamic contour tonometer in monitoring 10P after LASIK
    Kniestedt, C
    Kanngiesser, H
    Stamper, RL
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03): : 458 - 459
  • [46] Correlation of Intraocular Pressure Measured With Goldmann and Dynamic Contour Tonometry in Normal and Glaucomatous Eyes
    Realini, Tony
    Weinreb, Robert N.
    Hobbs, Gerald
    JOURNAL OF GLAUCOMA, 2009, 18 (02) : 119 - 123
  • [47] Comparison of Goldmann Applanation Tonometer, Noncontact Tonometer, and TonoPen XL for Intraocular Pressure Measurement in Different Types of Glaucomatous, Ocular Hypertensive, and Normal Eyes
    Kim, Na Rae
    Kim, Chan Yun
    Kim, Hyunjoong
    Seong, Gong Je
    Lee, Eun Suk
    CURRENT EYE RESEARCH, 2011, 36 (04) : 295 - 300
  • [48] Comparison of intraocular pressure measurement by Dynamic Contour Tonometry and Goldmann applanation tonometry
    DeBry, PW
    Krishna, R
    Willoughby, TL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U372 - U372
  • [49] Intraocular pressure measurement - Comparison of dynamic contour tonometry and Goldmann applanation tonometry
    Schneider, E
    Grehn, F
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 2 - 6
  • [50] Effectiveness of the Goldmann Applanation Tonometer, the Dynamic Contour Tonometer, the Ocular Response Analyzer and the Corvis ST in Measuring Intraocular Pressure following FS-LASIK
    Bao, Fangjun
    Huang, Wei
    Zhu, Rong
    Lu, Nanji
    Wang, Yuan
    Li, Hechen
    Wu, Songan
    Lin, Huini
    Wang, Junjie
    Zheng, Xiaobo
    Huang, JinHai
    Li, Yiyu
    Wang, Qinmei
    Elsheikh, Ahmed
    CURRENT EYE RESEARCH, 2020, 45 (02) : 144 - 152