The Measurement of Intraocular Pressure in Eyes with Keratoconus Using Pascal Dynamic Contour Tonometer

被引:0
|
作者
Ocakoglu, Ozcan [1 ]
Iskeleli, Guzin [1 ]
Ucar, Didar [1 ]
机构
[1] Istanbul Univ, Cerrahpafla Tip Fak, Goz Hastaliklari Ana Bilim Dali, Istanbul, Turkey
关键词
Keratoconus; Pascal dynamic contour tonometry; central corneal thickness;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare Pascal dynamic contour tonometer (DCT) with other tonometric systems for measurement of intraocular pressure (IOP) in eyes with keratoconus which has thinned cornea and topographically indicated keratoconus pattern and to investigate whether central corneal thickness (CCT) affect IOP measurements or not. Material and Method: Our study included 44 eyes of 28 patients which were diagnosed as keratoconus clinically and topographically. Their central corneal thicknesses which were measured with ultrasonographic pachymeter were under 500 microns (mu). IOP's were estimated using Pascal DCT, Goldmann applanation tonometer (GAT) and non contact air-puff tonometer (NCT). The "mean" IOP accepted as the mean of three consecutive measurements in different times. The "mean" IOP's values using Pascal DCT, GAT and NCT compared with paired student t test with each other. Statistically significance limit was p< 0,05. Pearson correlation analysis was used to determine the effect of CCT on IOP. Correlation coefficient was accepted r> 0,25 (p< 0,05). Results: The mean age of 28 patients with keratoconus was 30,18 +/- 8.8 years. In 44 study eyes, the mean value of CCT's was 465,8 +/- 24,1 mu. The mean values of IOP's using Pascal DCT, GAT and NCT were 14,3 +/- 2,3 mmHg, 11,1 +/- 2,6 mmHg, 8,11 +/- 1,9 mmHg, respectively. The mean IOP using Pascal DCT was statistically higher than the mean values of GAT and NCT (Student t test; p< 0,05). IOP measured with NCT were significantly correlated with CCT (Pearson correlation analysis r1= 0,26, p< 0,05) but IOP measured with GAT and Pascal DCT were not effected (for GAT r(2)= 0,09; for DKT r3= 0,06, p> 0,05). Conclusion: In eyes with keratoconus, the highest IOP value was measured with Pascal DCT. The measured IOP's using NCT was affected by the changes in CCT but the IOP's measured with Pascal DCT and GAT were not. When the technical problems with using GAT in eyes with keratoconus which was thinned and topographically distrurbed cornea are considered, we thought that to use Pascal DCT is more accurate and safely.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [1] Assessment of the Pascal dynamic contour tonometer in measuring intraocular pressure in keratoconic eyes
    Papavergiou, Georgios I.
    Kozobolis, Vasiliios
    Siganos, Dimitrios S.
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 484 - 488
  • [2] Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
    Siganos, DS
    Papastergiou, GI
    Moedas, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (04): : 746 - 751
  • [3] Ocular Pulse Amplitude Measurement Using Pascal Dynamic Contour Tonometer in Glaucoma Patients
    Katsimpris, J. M.
    Theoulakis, P. E.
    Papadopoulos, G. E.
    Katsimpris, A.
    Lepidas, J.
    Petropoulos, I. K.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2014, 231 (04) : 363 - 367
  • [4] Comparison of the quality score of intraocular pressure and ocular pulse amplitude values measured by the Pascal dynamic contour tonometer
    Pourjavan S.
    Boghossian P.
    Detry-Morel M.
    International Ophthalmology, 2010, 30 (1) : 1 - 5
  • [5] Clinical evaluation of the Pascal® dynamic contour tonometer
    Detry-Morel, M.
    Jamart, J.
    Detry, M. B.
    Ledoux, A.
    Pourjavan, S.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2007, 30 (03): : 260 - 270
  • [6] Measurement of intraocular pressure in pig's eyes using a new tonometer prototype
    Banobre, A
    Alvarez, TL
    Fechtner, RD
    Greene, RJ
    Thomas, GA
    Levi, O
    Ciampa, N
    2005 IEEE 31ST ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2005, : 260 - 261
  • [7] Intraocular Pressure Measurement Using Ocular Response Analyzer, Dynamic Contour Tonometer, and Scheimpflug Analyzer Corvis ST
    Ramm, Lisa
    Herber, Robert
    Spoerl, Eberhard
    Raiskup, Frederik
    Pillunat, Lutz E.
    Terai, Naim
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [8] Dynamic Contour Tonometer and Goldmann Applanation Tonometer Performance in a Developing World Setting: Intraocular Pressure Measurement Acquisition and Precision
    Cheng, Jason
    Salam, Tahrina
    Russell, Paul J.
    Heath, David G.
    Kotecha, Aachal
    JOURNAL OF GLAUCOMA, 2013, 22 (09) : 736 - 739
  • [9] Measurement of Intraocular Pressure with a Dynamic Tonometer and Presentation of Measurement Results
    M. Yu. Danichenko
    A. A. Mikheev
    Biomedical Engineering, 2022, 55 : 342 - 345
  • [10] Measurement of Intraocular Pressure with a Dynamic Tonometer and Presentation of Measurement Results
    Danichenko, M. Yu
    Mikheev, A. A.
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2022, 55 (05): : 342 - 345