THERMOACOUSTIC SENSOR FOR ULTRASOUND POWER MEASUREMENTS AND ULTRASONIC EQUIPMENT CALIBRATION

被引:21
|
作者
FAY, B
RINKER, M
LEWIN, PA
机构
[1] DREXEL UNIV,DEPT ELECT & COMP ENGN & BIOMED ENGN,PHILADELPHIA,PA 19104
[2] DREXEL UNIV,INST SCI,PHILADELPHIA,PA 19104
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1994年 / 20卷 / 04期
关键词
THERMOACOUSTIC SENSOR; ULTRASONIC EXPOSIMETRY; ULTRASONIC POWER; ULTRASONIC EQUIPMENT CALIBRATION;
D O I
10.1016/0301-5629(94)90005-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes a thermoacoustic sensor developed for measurements of the acoustic power and calibration of ultrasonic transducers in the medical imaging and nondestructive testing freqUenCY range. It is shown that the equilibrium temperature produced by ultrasound absorption in an absorbing material and detected by a copper-constantan thermocouple is proportional to the square of the current applied to the acoustic source. It is also demonstrated that the simultaneous measurement of this current and the corresponding equilibrium temperature at a given frequency allow the transmitting current sensitivity of the acoustic source to be calculated. The sensor thus provides a useful and low-cost alternative to the expensive calibration methods such as those based on the reciprocity technique, the planar scanning technique and the radiation force balance. The principles of the sensor's operation are outlined and its construction and characteristics are described. Experimental data in the frequency range of 1-8 MHz are presented and the advantages and disadvantages of the sensor are discussed.
引用
收藏
页码:367 / 373
页数:7
相关论文
共 50 条
  • [31] European intercomparison of ultrasonic power measurements
    Physikalisch-Technische, Bundesanstalt, Braunschweig, Germany
    Acta Acustica Stuttgart, 3 (450-458):
  • [32] ULTRASONIC CALORIMETER FOR BEAM POWER MEASUREMENTS
    ZAPF, TL
    HARVEY, ME
    LARSEN, NT
    STOLTENBERG, RE
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1977, 24 (02): : 139 - 139
  • [33] Process and equipment monitoring methodologies applied to sensor calibration monitoring
    Hines, J. Wesley
    Garvey, Dustin
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2007, 23 (01) : 123 - 135
  • [34] A thermoacoustic sensor for recording high-power nanosecond microwave pulses
    Andreev, V. G.
    Vdovin, V. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2009, 52 (02) : 226 - 229
  • [35] ASSESSMENT OF AN ULTRASONIC POWER-METER FOR DIAGNOSTIC EQUIPMENT
    SHAW, A
    CORNHILL, CV
    DAVIDSON, F
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726): : 553 - 553
  • [36] RELIABILITY OF ULTRASONIC INSPECTION OF WELD JOINTS OF POWER EQUIPMENT
    DIANOV, VF
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1989, 25 (09): : 617 - 622
  • [37] Measurements and calibration of equipment for UV content check in light sources
    Domke, Konrad
    Pelko, Marcin
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (04): : 78 - 79
  • [38] Attenuation of ultrasonic waves in steels for fittings in power equipment
    Ushakov, VM
    Grebennik, IL
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1997, 33 (10) : 717 - 721
  • [39] A system of automatic measurement of acoustic power of the ultrasonic equipment
    Khmelev, VN
    Tsyganok, SN
    Barsukov, RV
    Lebedev, AN
    2004 INTERNATIONAL SIBERIAN WORKSHOPS AND TUTORIALS ON ELECTRON DEVICES AND MATERIALS, EDM 2004, PROCEEDINGS, 2004, : 205 - 206
  • [40] A thermoacoustic sensor for recording high-power nanosecond microwave pulses
    V. G. Andreev
    V. A. Vdovin
    Instruments and Experimental Techniques, 2009, 52 : 226 - 229