THERMOACOUSTIC SENSOR FOR ULTRASOUND POWER MEASUREMENTS AND ULTRASONIC EQUIPMENT CALIBRATION

被引:21
|
作者
FAY, B
RINKER, M
LEWIN, PA
机构
[1] DREXEL UNIV,DEPT ELECT & COMP ENGN & BIOMED ENGN,PHILADELPHIA,PA 19104
[2] DREXEL UNIV,INST SCI,PHILADELPHIA,PA 19104
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1994年 / 20卷 / 04期
关键词
THERMOACOUSTIC SENSOR; ULTRASONIC EXPOSIMETRY; ULTRASONIC POWER; ULTRASONIC EQUIPMENT CALIBRATION;
D O I
10.1016/0301-5629(94)90005-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes a thermoacoustic sensor developed for measurements of the acoustic power and calibration of ultrasonic transducers in the medical imaging and nondestructive testing freqUenCY range. It is shown that the equilibrium temperature produced by ultrasound absorption in an absorbing material and detected by a copper-constantan thermocouple is proportional to the square of the current applied to the acoustic source. It is also demonstrated that the simultaneous measurement of this current and the corresponding equilibrium temperature at a given frequency allow the transmitting current sensitivity of the acoustic source to be calculated. The sensor thus provides a useful and low-cost alternative to the expensive calibration methods such as those based on the reciprocity technique, the planar scanning technique and the radiation force balance. The principles of the sensor's operation are outlined and its construction and characteristics are described. Experimental data in the frequency range of 1-8 MHz are presented and the advantages and disadvantages of the sensor are discussed.
引用
收藏
页码:367 / 373
页数:7
相关论文
共 50 条
  • [21] Heuristic based approach for extracting calibration parameters of ultrasound equipment
    Boctor, EM
    Saad, AA
    Youssef, ABM
    Graham, J
    INTELLIGENT SYSTEMS, 1997, : 97 - 100
  • [22] Study on the calibration of wideband power sensor
    National Institute of Metrology, Beijing 100013, China
    Yi Qi Yi Biao Xue Bao, 2007, SUPPL. 2 (303-307):
  • [23] Low power sensor calibration at KRISS
    Kim, JH
    Park, JI
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 654 - 655
  • [24] Thermoacoustic ultrasound power measurement using evaluation of transient temperature profiles
    Wilkens, V
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1399 - 1402
  • [25] A sensor used for measurements in the calibration of production robots
    Everett, LJ
    Ives, TW
    IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 1996, 12 (01): : 121 - 125
  • [26] Calibration and testing in voltammetric and amperometric sensor measurements
    Pavel, S
    Martin, A
    Radimir, V
    Krejci, J
    Jan, P
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 3068 - 3070
  • [27] AIRCRAFT MEASUREMENTS FOR CALIBRATION OF AN ORBITING SPACECRAFT SENSOR
    HOVIS, WA
    KNOLL, JS
    SMITH, GR
    APPLIED OPTICS, 1985, 24 (03): : 407 - 410
  • [28] Calibration of Hall sensor AC loss measurements
    Staines, M
    Rupp, S
    Caplin, D
    Yu, DG
    Fleshler, S
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 2224 - 2227
  • [29] Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor
    Wilkens, V
    Reimann, HP
    AMUM 2004: ADVANCED METROLOGY FOR ULTRASOUND IN MEDICINE 2004, 2004, 1 : 140 - 145
  • [30] European intercomparison of ultrasonic power measurements
    Beissner, K
    Oosterbaan, WA
    Hekkenberg, RT
    Shaw, A
    ACUSTICA, 1996, 82 (03): : 450 - 458