Measurement of polyacrylamide polymers in water and wastewater using an in-line UV-vis spectrophotometer

被引:33
|
作者
Al Momani, Fares A. [1 ]
Ormeci, Banu [1 ]
机构
[1] Carleton Univ, Dept Civil & Environm Engn, 1125 Colonel Dr, Ottawa, ON K1S 5B6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Measurement; Polymer; Acrylamide; Wastewater; Water;
D O I
10.1016/j.jece.2014.02.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measurement of polymers in water and wastewater is a major challenge, and there is currently no quick and simple method that can achieve this. This study presents a method for quantification of polyacrylamide concentration using an in-line UV-vis spectrophotometer that can generate real-time data. Absorbance spectra of seven polymers were established in the wavelength range of 191.5-750 nm and the highest absorbance was recorded at 191.5 nm for all polymers. UV absorbance of the polymers gradually decreased between 191.5-240 nm and a strong linear relationship ( R-2 > 0.97) between concentration and absorbance held at 191.5, 200 and 210 nm. Detection limits were established in distilled water and in four other samples collected from water and wastewater treatment plants. Polymer chemistry and presence of organic and inorganic impurities impacted the detection limits. In distilled water samples, the lowest detection limit measured was 0.05 mg/L. In samples collected from water and wastewater treatment plants, detection limits varied between 0.07 and 1.35 mg/L depending on the polymer type and water quality. Polymers are known to be toxic to aquatic ecosystems and they are suspected carcinogens, and the presented method could be useful in monitoring the polymer concentrations and minimizing its excessive use. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:765 / 772
页数:8
相关论文
共 50 条
  • [41] Investigation on absorption performance between cement and emulsified asphalt with UV-Vis spectrophotometer
    Wang, Zhenjun
    Wang, Hongfei
    Zhang, Ting
    Xu, Chuang
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 136 : 256 - 264
  • [42] Evaluation of the impact of suspended particles on the UV absorbance at 254 nm (UV254) measurements using a submersible UV-Vis spectrophotometer
    Zhining Shi
    Christopher W. K. Chow
    Rolando Fabris
    Tianlong Zheng
    Jixue Liu
    Bo Jin
    Environmental Science and Pollution Research, 2021, 28 : 12576 - 12586
  • [43] Evaluation of the impact of suspended particles on the UV absorbance at 254 nm (UV254) measurements using a submersible UV-Vis spectrophotometer
    Shi, Zhining
    Chow, Christopher W. K.
    Fabris, Rolando
    Zheng, Tianlong
    Liu, Jixue
    Jin, Bo
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2021, 28 (10) : 12576 - 12586
  • [44] Operando UV-Vis spectroscopy as potential in-line PAT system for size determination of functioning metal nanocatalysts
    Mohammadparast, Farshid
    Tirumala, Ravi Teja Addanki
    Ramakrishnan, Sundaram Bhardwaj
    Dadgar, Andishaeh P.
    Andiappan, Marimuthu
    CHEMICAL ENGINEERING SCIENCE, 2020, 225 (225)
  • [45] Spectrophotometer on-the-go: The development of a 2-in-1 UV-Vis portable Arduino-based spectrophotometer
    Poh, Jun-Jie
    Wu, Wei-Ling
    Goh, Nicholas Wei-Jie
    Tan, Samuel Ming-Xuan
    Gan, Samuel Ken-En
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 325
  • [46] On-line concentration measurement for anti-solvent crystallization of β-artemether using UV-vis fiber spectroscopy
    Zhang, Yang
    Jiang, Yanbin
    Zhang, Duanke
    Li, Kaixia
    Qian, Yu
    JOURNAL OF CRYSTAL GROWTH, 2011, 314 (01) : 185 - 189
  • [47] Use of Ionic Liquids for Preconcentration/Separation of Diazinon by In Situ Solvent Formation Microextraction (ISFME) and Measurement by the UV-Vis Spectrophotometer
    Sedaghati, Soheila
    Dalali, Naser
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND ALLIED SCIENCES, 2019, 8 (03): : 164 - 171
  • [48] Effect of Temperature on COD Measurement by UV-Vis Spectroscopy
    Jiang Zhengfu
    Li Xisheng
    Shi Peihua
    PROCEEDINGS OF ICRCA 2018: 2018 THE 3RD INTERNATIONAL CONFERENCE ON ROBOTICS, CONTROL AND AUTOMATION / ICRMV 2018: 2018 THE 3RD INTERNATIONAL CONFERENCE ON ROBOTICS AND MACHINE VISION, 2018, : 123 - 126
  • [49] Measurement of the index of refraction of solids by UV-Vis spectroscopy
    Bozlee, BJ
    Exharos, GJ
    Jimenez, AE
    van Swam, SL
    JOURNAL OF CHEMICAL EDUCATION, 2002, 79 (05) : 619 - 622
  • [50] CARBONACEOUS CLUSTERS IN IRRADIATED POLYMERS AS REVEALED BY UV-VIS SPECTROMETRY
    FINK, D
    CHUNG, WH
    KLETT, R
    SCHMOLDT, A
    CARDOSO, J
    MONTIEL, R
    VAZQUEZ, MH
    WANG, L
    HOSOI, F
    OMICHI, H
    GOPPELTLANGER, P
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 1995, 133 (03): : 193 - 208