SIMULTANEOUS KINETIC-BASED DETERMINATION OF FRUCTOSE AND ASCORBATE WITH A ROTATING BIOREACTOR AND AMPEROMETRIC DETECTION - APPLICATION TO THE ANALYSIS OF FOOD SAMPLES

被引:32
|
作者
MATSUMOTO, K
BAEZA, JJB
MOTTOLA, HA
机构
[1] OKLAHOMA STATE UNIV,DEPT CHEM,STILLWATER,OK 74078
[2] UNIV VALENCIA,FAC MED,DEPT ANALYT CHEM,VALENCIA,SPAIN
[3] KYUSHU UNIV,FAC AGR,DEPT FOOD SCI & TECHNOL,FUKUOKA 812,JAPAN
关键词
D O I
10.1021/ac00061a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A recently introduced biosensor comprising a rotating bioreactor and a stationary platinum ring amperometric detector (Anal. Chem. 1993, 65, 636-639) has been utilized for the simultaneous determination of fructose and ascorbate. The approach has been successfully applied to the simultaneous determination of these analytes in fresh food samples. Hexacyanoferrate(II) is the monitored species at +0.380 V vs a Ag/AgCl, 3 M NaCl reference. The determination takes advantage of a fast chemical oxidation of ascorbate by hexacyanoferrate(III) ions and the subsequent slower production of hexacyanoferrate(II) in the D-fructose 5-dehydrogenase-catalyzed reaction between D-fructose and hexacyanoferrate(III) as acceptor. D-Fructose 5-dehydrogenase (EC 1.1.99.11) was incorporated into the rotating disk reactor in immobilized form and on controlled-pore glass via the glutaraldehyde attachment and cross-linking with bovine serum albumin. Sample/reagent processing was accomplished by programmed continuous-flow/stopped-flow/continuous-flow operation.
引用
收藏
页码:1658 / 1661
页数:4
相关论文
共 20 条
  • [1] COMPARATIVE-STUDIES ON DATA-COLLECTION AND DATA TREATMENT IN KINETIC-BASED DETERMINATIONS WITH 2 ROTATING BIOREACTOR AMPEROMETRIC DETECTION SYSTEMS
    BAEZA, JJB
    MATSUMOTO, K
    MOTTOLA, HA
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (02) : 785 - 793
  • [2] Simultaneous spec trophotometric determination of ascorbic acid and glutathione by kinetic-based flow injection analysis
    Teshima, Norio
    Nobuta, Takuya
    Sakai, Tadao
    [J]. BUNSEKI KAGAKU, 2008, 57 (05) : 327 - 333
  • [3] Amperometric mediated carbon paste biosensor based on D-fructose dehydrogenase for the determination of fructose in food analysis
    Paredes, PA
    Parellada, J
    Fernandez, VM
    Katakis, I
    Dominguez, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (12): : 1233 - 1243
  • [4] Rapid simultaneous determination of alkylxanthines by CZE and its application in analysis of pharmaceuticals and food samples
    Regan, F
    Shakalisava, Y
    [J]. ANALYTICA CHIMICA ACTA, 2005, 540 (01) : 103 - 110
  • [5] Simultaneous Detection of Glucose and Fructose in Synthetic Musts by Multivariate Analysis of Silica-Based Amperometric Sensor Signals
    Crespo-Rosa, Joaquin Rafael
    Foca, Giorgia
    Ulrici, Alessandro
    Pigani, Laura
    Zanfrognini, Barbara
    Cubillana-Aguilera, Laura
    Palacios-Santander, Jose Maria
    Zanardi, Chiara
    [J]. SENSORS, 2021, 21 (12)
  • [6] Development of an Analytical Protocol for Determination of Cyanide in Human Biological Samples Based on Application of Ion Chromatography with Pulsed Amperometric Detection
    Jaszczak, Ewa
    Ruman, Marek
    Narkowicz, Sylwia
    Namiesnik, Jacek
    Polkowska, Zaneta
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2017, 2017
  • [7] Simultaneous determination of neutral sugars, alditols and anhydrosugars using anion-exchange chromatography with pulsed amperometric detection: Application for marine and atmospheric samples
    Nouara, Amel
    Panagiotopoulos, Christos
    Sempere, Richard
    [J]. MARINE CHEMISTRY, 2019, 213 : 24 - 32
  • [8] Selective and simultaneous determination of indigo carmine and allura red in candy samples at the nano-concentration range by flow injection analysis with multiple pulse amperometric detection
    Deroco, Patricia B.
    Medeiros, Roberta A.
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    [J]. FOOD CHEMISTRY, 2018, 247 : 66 - 72
  • [9] Rotating bioreactor based on an electron transfer mediated by osmium complexes incorporating a continuous-flow/stopped-flow system - Application to the determination of glucose in serum samples
    Lapierre, AV
    Battaglini, F
    Raba, J
    [J]. ANALYTICA CHIMICA ACTA, 2001, 443 (01) : 17 - 24
  • [10] Simultaneous determination of iron, copper and cobalt in food samples by diode array detection-flow injection analysis using partial least squares calibration model
    Mi Jian-ping
    Li Yuan-qian
    Zou Xiao-li
    Zheng Bo
    Yang Jing-guo
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (06) : 1188 - 1191