ABSORBABLE PLUGS OF SELF-REINFORCED POLY-L-LACTIC ACID IN THE INTERNAL-FIXATION OF RABBIT DISTAL FEMORAL OSTEOTOMIES

被引:0
|
作者
PIHLAJAMAKI, H
BOSTMAN, O
MANNINEN, M
PAIVARINTA, U
TORMALA, P
ROKKANEN, P
机构
[1] UNIV HELSINKI,CENT HOSP,DEPT ORTHOPAED & TRAUMATOL,HELSINKI,FINLAND
[2] UNIV TECHNOL TAMPERE,BIOMAT LAB,TAMPERE,FINLAND
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
An absorbable plug for the internal fixation of fractures and osteotomies, measuring 4.5 mm in diameter and 30 mm in length, was constructed of poly-L-lactide using a self-reinforcing fibers-inmatrix manufacturing technique. To increase the rotational stability and grip of the device, the plug has deployable distal fins. The plug was used in the fixation of a transverse distal femoral osteotomy in 20 rabbits. The consolidation of the osteotomy was investigated histologically, histomorphometrically, and microradiographically in groups of five rabbits observed for three, six, 12, or 24 weeks. Fifteen osteotomies showed bony union. In five rabbits, no bridging trabeculae across the osteotomy had developed, but these rabbits belonged to the groups with the shortest follow-up times of three or six weeks. No mechanical failures of the plugs were encountered, and the short-term biocompatibility of the implant was excellent. Future clinical applications are planned.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 50 条
  • [1] ABSORBABLE PINS OF SELF-REINFORCED POLY-L-LACTIC ACID FOR FIXATION OF FRACTURES AND OSTEOTOMIES
    PIHLAJAMAKI, H
    BOSTMAN, O
    HIRVENSALO, E
    TORMALA, P
    ROKKANEN, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (06): : 853 - 857
  • [2] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 30 (04): : 417 - 421
  • [3] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide plates - An experimental study on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (6-7) : 352 - 356
  • [4] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide platesAn experimental study on rabbits
    K. Koskikare
    E. Hirvensalo
    H. Pätiälä
    P. Rokkanen
    T. Pohjonen
    P. Törmälä
    G. Lob
    [J]. Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 352 - 356
  • [5] ABSORBABLE POLYGLYCOLIDE SCREWS IN INTERNAL-FIXATION OF FEMORAL OSTEOTOMIES IN RABBITS
    BOSTMAN, O
    PAIVARINTA, U
    PARTIO, E
    MANNINEN, M
    MAJOLA, A
    VASENIUS, J
    ROKKANEN, P
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (06): : 587 - 591
  • [6] FIXATION OF SUBCAPITAL FEMORAL OSTEOTOMIES BY POLY-L-LACTIC ACID PINS - AN EXPERIMENTAL-STUDY IN SHEEP
    VASENIUS, J
    LAITINEN, O
    POHJONEN, T
    VAINIONPAA, S
    TORMALA, P
    ROKKANEN, P
    [J]. INTERNATIONAL ORTHOPAEDICS, 1993, 17 (03) : 144 - 147
  • [7] Comparison of intra- and extraosseally placed self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies in rabbits
    Koskikare, K
    Pihlajamaki, H
    Patiala, H
    Rokkanen, P
    [J]. ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1997, 86 (03) : 261 - 268
  • [8] SHEAR-STRENGTH OF CANCELLOUS BONE AFTER OSTEOTOMY FIXED WITH ABSORBABLE SELF-REINFORCED POLYGLYCOLIC ACID AND POLY-L-LACTIC ACID RODS
    MANNINEN, MJ
    PAIVARINTA, U
    PATIALA, H
    ROKKANEN, P
    TAURIO, R
    TAMMINMAKI, M
    TORMALA, P
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1992, 3 (04) : 245 - 251
  • [9] Comparison of the fixation of subcapital femoral neck osteotomies with absorbable self-reinforced poly-L-lactide lag-screws or metallic screws in sheep
    JukkalaPartio, K
    Laitinen, O
    Partio, EK
    Vasenius, J
    Vainionpaa, S
    Pohjonen, T
    Tormala, P
    Rokkanen, P
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) : 124 - 127
  • [10] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30 and self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rabbits
    Pyhältö, T
    Lapinsuo, M
    Pätiälä, H
    Niiranen, H
    Törmälä, P
    Rokkanen, P
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2005, 16 (06) : 725 - 744