Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30 and self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rabbits

被引:8
|
作者
Pyhältö, T
Lapinsuo, M
Pätiälä, H
Niiranen, H
Törmälä, P
Rokkanen, P
机构
[1] Univ Helsinki, Cent Hosp, Dept Orthopaed & Traumatol, FIN-00029 Helsinki, Finland
[2] Tampere Univ Technol, Inst Biomat, FIN-33101 Tampere, Finland
关键词
bioabsorbable rods; self-reinforced; poly(L/DL)lactide; SR-PLA(70); osteotomy fixation;
D O I
10.1163/1568562053992513
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two self-reinforced poly(L/DL)lactide 70: 30 or self-reinforced poly(L/DL)lactide 70: 30/ bioactive glass (SR-P(L/DL)LA/bioactive glass) composite rods (2 mm x 40 mm) were implanted into the dorsal subcutaneous tissue and osteotomies of the distal femur were fixed with these rods (2 mm x 26 mm) in 36 rabbits. The follow-up times varied from 3 to 100 weeks. After the animals were killed, three-point bending and shear tests and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. After 12 weeks the SR-P(L/DL)LA rods had fragmented into pieces and the mechanical properties could not be measured. The SR-P(L/DL)LA/bioactive glass rods lost their mechanical properties slower, and at 24 weeks the bending strength had decreased by 39% and the shear strength by 50%. After that the mechanical properties of the SR-P(L/DL)LA/bioactive glass rods could not be measured. All osteotomies healed well, and no gross signs of inflammatory reactions were observed. One slight displacement was seen in the three-week follow-up group with SR-P(L/DL)LA rods. Signs of resorption of the implants were seen after 48 weeks in the SR-P(L/DL)LA group and after 24 weeks in the SR-P(L/DL)LA/bioactive glass group. The SR-P(L/DL)LA/bioactive glass rods were almost totally resorbed from the bone at 100 weeks. The present investigation showed that the mechanical strength and fixation properties of the SR-P(L/DL)LA and the SR-P(L/DL)LA/bioactive glass composite rods are suitable for fixation of cancellous bone osteotomies in rabbits.
引用
收藏
页码:725 / 744
页数:20
相关论文
共 50 条
  • [1] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rats
    Tuomo, P
    Matti, L
    Hannu, P
    Pentti, R
    Henna, N
    Pertti, T
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (03) : 275 - 281
  • [2] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70 : 30/bioactive glass composite rods. An experimental study on rats
    Pyhältö Tuomo
    Lapinsuo Matti
    Pätiälä Hannu
    Rokkanen Pentti
    Niiranen Henna
    Törmälä Pertti
    [J]. Journal of Materials Science: Materials in Medicine, 2004, 15 : 275 - 281
  • [3] Strength retention of self-reinforced drawn poly-L/DL-lactide 70/30 (SR-PLA70) rods and fixation properties of distal femoral osteotomies with these rods.: An experimental study on rats
    Joukainen, A
    Pihlajamäki, H
    Mäkelä, EA
    Ashammakhi, N
    Viljanen, J
    Pätiälä, H
    Kellomäki, M
    Törmälä, P
    Rokkanen, P
    [J]. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (12) : 1411 - 1428
  • [4] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide plates - An experimental study on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (6-7) : 352 - 356
  • [5] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide platesAn experimental study on rabbits
    K. Koskikare
    E. Hirvensalo
    H. Pätiälä
    P. Rokkanen
    T. Pohjonen
    P. Törmälä
    G. Lob
    [J]. Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 352 - 356
  • [6] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 30 (04): : 417 - 421
  • [7] Fixation of distal femoral osteotomies with self-reinforced polymer/bioactive glass rods:: an experimental study on rabbits
    Pyhältö, T
    Lapinsuo, M
    Pätiälä, H
    Pelto, M
    Törmälä, P
    Rokkanen, P
    [J]. BIOMATERIALS, 2005, 26 (06) : 645 - 654
  • [8] Fixation of femoral shaft osteotomy with intramedullary self-reinforced poly-L-lactide rods.: An experimental study on growing dogs
    Lautiainen, I
    Nevalainen, T
    Rokkanen, P
    Törmälä, P
    Mäkelä, EA
    [J]. SIROT 99, 1999, : 239 - 247
  • [9] SELF-REINFORCED POLY-L-LACTIDE SCREWS IN THE FIXATION OF CORTICAL BONE OSTEOTOMIES IN RABBITS
    MANNINEN, MJ
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (02) : 179 - 185
  • [10] Comparison of intra- and extraosseally placed self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies in rabbits
    Koskikare, K
    Pihlajamaki, H
    Patiala, H
    Rokkanen, P
    [J]. ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1997, 86 (03) : 261 - 268