Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70 : 30/bioactive glass composite rods. An experimental study on rats

被引:0
|
作者
Pyhältö Tuomo
Lapinsuo Matti
Pätiälä Hannu
Rokkanen Pentti
Niiranen Henna
Törmälä Pertti
机构
[1] Helsinki University Central Hospital,Department of Orthopaedics and Traumatology
[2] Tampere University of Technology,Institute of Biomaterials
关键词
Mechanical Strength; Lactide; Present Article; Operative Technique; Subcutaneous Tissue;
D O I
暂无
中图分类号
学科分类号
摘要
Self-reinforced poly(L/DL)lactide 70 : 30/bioactive glass [SR-P(L/DL)LA/bioactive glass] composite rods, 2 mm in diameter and 36 mm in length, were implanted into the dorsal subcutaneous tissue of 16 rats. Osteotomies of the distal femur were fixed with these rods (2×15 mm) in 64 other rats. The follow-up times varied from one week to one year. After sacrifice, three-point bending and shear tests, and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic, and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. At 24 weeks the mechanical properties had decreased significantly. Thirty-nine osteotomies healed uneventfully. One of the 64 evaluated osteotomies showed signs of infection at six weeks, and there were 19 non-unions and six delayed unions. In 20 operations the fixation was loose and out of these 14 non-unions were observed. No gross signs of inflammatory or foreign-body reactions were observed. The present investigation showed that the mechanical strength and fixation properties of SR-P(L/DL)LA/bioactive glass composite rods are suitable for fixation of cancellous bone osteotomies in rats as long as the operative technique is correct. The present article is the first report on the application of SR-P(L/DL)LA/bioactive glass composite rods for fixation of cancellous bone osteotomies.
引用
收藏
页码:275 / 281
页数:6
相关论文
共 46 条
  • [1] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rats
    Tuomo, P
    Matti, L
    Hannu, P
    Pentti, R
    Henna, N
    Pertti, T
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2004, 15 (03) : 275 - 281
  • [2] Fixation of distal femoral osteotomies with self-reinforced poly(L/DL)lactide 70:30 and self-reinforced poly(L/DL)lactide 70:30/bioactive glass composite rods.: An experimental study on rabbits
    Pyhältö, T
    Lapinsuo, M
    Pätiälä, H
    Niiranen, H
    Törmälä, P
    Rokkanen, P
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2005, 16 (06) : 725 - 744
  • [3] Strength retention of self-reinforced drawn poly-L/DL-lactide 70/30 (SR-PLA70) rods and fixation properties of distal femoral osteotomies with these rods.: An experimental study on rats
    Joukainen, A
    Pihlajamäki, H
    Mäkelä, EA
    Ashammakhi, N
    Viljanen, J
    Pätiälä, H
    Kellomäki, M
    Törmälä, P
    Rokkanen, P
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2000, 11 (12) : 1411 - 1428
  • [4] Fixation of distal femoral osteotomies with self-reinforced polymer/bioactive glass rods:: an experimental study on rabbits
    Pyhältö, T
    Lapinsuo, M
    Pätiälä, H
    Pelto, M
    Törmälä, P
    Rokkanen, P
    BIOMATERIALS, 2005, 26 (06) : 645 - 654
  • [5] Strength retention of drawn self-reinforced polyglycolide rods and fixation properties of the distal femoral osteotomies with these rods.: An experimental study on rats
    Pihlajamäki, H
    Mäkelä, EA
    Ashammakhi, N
    Viljanen, J
    Pätiälä, H
    Rokkanen, P
    Pohjonen, T
    Törmälä, P
    Joukainen, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (04) : 389 - 395
  • [6] Strength retention of drawn self-reinforced polyglycolide rods and fixation properties of the distal femoral osteotomies with these rods. An experimental study on rats
    Harri Pihlajamäki
    E. Antero Mäkelä
    Nureddin Ashammakhi
    Janne Viljanen
    Hannu Pätiälä
    Pentti Rokkanen
    Timo Pohjonen
    Pertti Törmälä
    Antti Joukainen
    Journal of Materials Science: Materials in Medicine, 2002, 13 : 389 - 395
  • [7] Fixation of femoral shaft osteotomy with intramedullary self-reinforced poly-L-lactide rods.: An experimental study on growing dogs
    Lautiainen, I
    Nevalainen, T
    Rokkanen, P
    Törmälä, P
    Mäkelä, EA
    SIROT 99, 1999, : 239 - 247
  • [8] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide platesAn experimental study on rabbits
    K. Koskikare
    E. Hirvensalo
    H. Pätiälä
    P. Rokkanen
    T. Pohjonen
    P. Törmälä
    G. Lob
    Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 352 - 356
  • [9] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide plates - An experimental study on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (6-7) : 352 - 356
  • [10] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Helsinki University, Central Hospital, Topeliuksenkatu 5, FIN-00260 Helsinki, Finland
    不详
    不详
    J. BIOMED. MATER. RES., 4 (417-421):