Self-reinforced poly(L/DL)lactide 70 : 30/bioactive glass [SR-P(L/DL)LA/bioactive glass] composite rods, 2 mm in diameter and 36 mm in length, were implanted into the dorsal subcutaneous tissue of 16 rats. Osteotomies of the distal femur were fixed with these rods (2×15 mm) in 64 other rats. The follow-up times varied from one week to one year. After sacrifice, three-point bending and shear tests, and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic, and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. At 24 weeks the mechanical properties had decreased significantly. Thirty-nine osteotomies healed uneventfully. One of the 64 evaluated osteotomies showed signs of infection at six weeks, and there were 19 non-unions and six delayed unions. In 20 operations the fixation was loose and out of these 14 non-unions were observed. No gross signs of inflammatory or foreign-body reactions were observed. The present investigation showed that the mechanical strength and fixation properties of SR-P(L/DL)LA/bioactive glass composite rods are suitable for fixation of cancellous bone osteotomies in rats as long as the operative technique is correct. The present article is the first report on the application of SR-P(L/DL)LA/bioactive glass composite rods for fixation of cancellous bone osteotomies.
引用
收藏
页码:275 / 281
页数:6
相关论文
共 46 条
  • [11] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 30 (04): : 417 - 421
  • [12] Comparison of intra- and extraosseally placed self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies in rabbits
    Koskikare, K
    Pihlajamaki, H
    Patiala, H
    Rokkanen, P
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1997, 86 (03) : 261 - 268
  • [13] SELF-REINFORCED POLY-L-LACTIDE SCREWS IN THE FIXATION OF CORTICAL BONE OSTEOTOMIES IN RABBITS
    MANNINEN, MJ
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (02) : 179 - 185
  • [14] Absorbable self-reinforced poly-L-lactide plates in the fixation of osteotomies of the distal femur with special reference to the site of implantation. An experimental study.
    Koskikare, K
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1999, 88 (01) : 79 - 80
  • [15] Intramedullary fixation of distal femoral diaphyseal osteotomies with absorbable self-reinforced poly-L-lactide and metallic intramedullary rods assessed by plain radiographs, quantitative computed tomography, and magnetic resonance imaging: An experimental study in rabbits
    Viljanen, J
    Kinnunen, T
    Bondestam, S
    Rokkanen, P
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 39 (02): : 222 - 228
  • [16] ABSORBABLE PLUGS OF SELF-REINFORCED POLY-L-LACTIC ACID IN THE INTERNAL-FIXATION OF RABBIT DISTAL FEMORAL OSTEOTOMIES
    PIHLAJAMAKI, H
    BOSTMAN, O
    MANNINEN, M
    PAIVARINTA, U
    TORMALA, P
    ROKKANEN, P
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 277 - 285
  • [17] Healing of subcapital femoral osteotomies fixed with self-reinforced poly-L-lactide screws: an experimental long-term study in sheep
    Kirsi Jukkala-Partio
    Outi Laitinen
    Jarkko Vasenius
    Esa K. Partio
    Terttu Toivonen
    Pekka Tervahartiala
    Jaakko Kinnunen
    Pentti Rokkanen
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 360 - 364
  • [18] Healing of subcapital femoral osteotomies fixed with self-reinforced poly-L-lactide screws: an experimental long-term study in sheep
    Jukkala-Partio, K
    Laitinen, O
    Vasenius, J
    Partio, EK
    Toivonen, T
    Tervahartiala, P
    Kinnunen, J
    Rokkanen, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (06) : 360 - 364
  • [19] Holding power of bioabsorbable ciprofloxacin-containing self-reinforced poly-L/DL-lactide 70/30 bioactive glass 13 miniscrews in human cadaver bone
    Leinonen, S
    Suokas, E
    Veiranto, M
    Törmälä, P
    Waris, T
    Ashammakhi, N
    JOURNAL OF CRANIOFACIAL SURGERY, 2002, 13 (02) : 212 - 218
  • [20] Fixation of mandibular body osteotomies using biodegradable amorphous self-reinforced (70L:30DL) polylactide or metal lag screws:: an experimental study in sheep
    Kallela, I
    Tulamo, RM
    Hietanen, J
    Pohjonen, T
    Suuronen, R
    Lindqvist, C
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (02) : 124 - 133