We reviewed 27 patients with small-fragment fractures or osteotomies treated by internal fixation with absorbable self-reinforced poly-L-lactide pins. The follow-up time ranged from eight to 37 months. The two most common indications were chevron osteotomy of the first metatarsal bone for hallux valgus and displaced fracture of the radial head. No redisplacements occurred, and there were no signs of inflammatory foreign-body reaction. Biopsy in two patients 20 and 37 months after implantation showed that no polymeric material remained.
引用
收藏
页码:853 / 857
页数:5
相关论文
共 50 条
  • [1] ABSORBABLE PLUGS OF SELF-REINFORCED POLY-L-LACTIC ACID IN THE INTERNAL-FIXATION OF RABBIT DISTAL FEMORAL OSTEOTOMIES
    PIHLAJAMAKI, H
    BOSTMAN, O
    MANNINEN, M
    PAIVARINTA, U
    TORMALA, P
    ROKKANEN, P
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1994, (298) : 277 - 285
  • [2] FIXATION OF SUBCAPITAL FEMORAL OSTEOTOMIES BY POLY-L-LACTIC ACID PINS - AN EXPERIMENTAL-STUDY IN SHEEP
    VASENIUS, J
    LAITINEN, O
    POHJONEN, T
    VAINIONPAA, S
    TORMALA, P
    ROKKANEN, P
    [J]. INTERNATIONAL ORTHOPAEDICS, 1993, 17 (03) : 144 - 147
  • [3] SHEAR-STRENGTH OF CANCELLOUS BONE AFTER OSTEOTOMY FIXED WITH ABSORBABLE SELF-REINFORCED POLYGLYCOLIC ACID AND POLY-L-LACTIC ACID RODS
    MANNINEN, MJ
    PAIVARINTA, U
    PATIALA, H
    ROKKANEN, P
    TAURIO, R
    TAMMINMAKI, M
    TORMALA, P
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1992, 3 (04) : 245 - 251
  • [4] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide plates - An experimental study on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (6-7) : 352 - 356
  • [5] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 30 (04): : 417 - 421
  • [6] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide platesAn experimental study on rabbits
    K. Koskikare
    E. Hirvensalo
    H. Pätiälä
    P. Rokkanen
    T. Pohjonen
    P. Törmälä
    G. Lob
    [J]. Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 352 - 356
  • [7] Shear-load carrying capacities of the distal rat femora after osteotomy fixed with self-reinforced polyglycolic acid and poly-L-lactic acid pins
    Pia Nordström
    Timo Pohjonen
    Pertti Törmälä
    Pentti Rokkanen
    [J]. Journal of Materials Science: Materials in Medicine, 2002, 13 : 65 - 68
  • [8] Shear-load carrying capacities of the distal rat femora after osteotomy fixed with self-reinforced polyglycolic acid and poly-L-lactic acid pins
    Nordström, P
    Pohjonen, T
    Törmälä, P
    Rokkanen, P
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2002, 13 (01) : 65 - 68
  • [9] MRI study of bioabsorbable poly-L-lactic acid devices used for fixation of fracture and osteotomies
    Marumo, K
    Sato, Y
    Suzuki, H
    Kurosaka, D
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2006, 11 (02) : 154 - 158
  • [10] Shear-load carrying capacity of cancellous bone after implantation of self-reinforced polyglycolic acid and poly-L-lactic acid pins:: experimental study on rats
    Nordström, P
    Pohjonen, T
    Törmälä, P
    Rokkanen, P
    [J]. BIOMATERIALS, 2001, 22 (18) : 2557 - 2561