RECEPTION TUNING OF GAS-SENSOR MICROSYSTEMS BY SELECTIVE COATINGS

被引:22
|
作者
ALTHAINZ, P [1 ]
DAHLKE, A [1 ]
FRIETSCHKLARHOF, M [1 ]
GOSCHNICK, J [1 ]
ACHE, HJ [1 ]
机构
[1] KERNFORSCHUNGSZENTRUM KARLSRUHE GMBH,INST RADIOCHEM,D-76021 KARLSRUHE,GERMANY
关键词
ARRAY MICROSYSTEMS; GAS SENSORS; TIN OXIDE;
D O I
10.1016/0925-4005(95)85082-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Selectively permeable SiO2 and Al2O3 coatings have been developed to customize the selectivity and improve the stability of SnO2 conductivity sensors of array microsystems for the detection of organic gases in air. The membranes have been prepared by chemical vapour deposition in thicknesses of 1-70 nm. While Al2O3 is obtained by pyrolysis of Al(OC3H7)(3), SiO2 membranes are produced from Si(C6H5)(OC2H5)(3) with ion-beam assistance at room temperature. Thereby, initially considerable amounts of carbon are incorporated into the bulk of the membrane, which are afterwards removed by heating to 350 degrees C, the operation temperature of the sensors. Tests of the coated sensors with air containing water, methane, propane, benzene and toluene show the intended selectivity change with respect to the naked sensors. The results are interpreted in terms of size-selective transport through the membrane and selective adsorption of aromatics. Up to 20 nm thickness, the membranes cause enhanced selectivity for small molecules such as water and methane accompanied by propane discrimination and a preferred toluene detection. Signal reduction due to the coating is less than a factor of 10. The response time is increased up to 250 s only for low concentrations.
引用
收藏
页码:366 / 369
页数:4
相关论文
共 50 条
  • [31] Excimer laser annealing of perovskite thin films: morphology and gas-sensor properties
    Du, X.
    Tunney, J.
    Post, M.
    Dubowski, J. J.
    [J]. COLA'05: 8TH INTERNATIONAL CONFERENCE ON LASER ABLATION, 2007, 59 : 50 - +
  • [32] Thermal analysis and design of a micro-hotplate for integrated gas-sensor applications
    Fung, SKH
    Tang, ZN
    Chan, PCH
    Sin, JKO
    Cheung, PW
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) : 482 - 487
  • [33] THE KINETIC SEMICONDUCTOR GAS-SENSOR CONDUCTION MODEL AND ITS PRACTICAL USE IN GAS-ANALYSIS
    GUTMAN, EY
    MYASNIKOV, IA
    KAZAKOV, SA
    RUGENTSEV, SV
    DYMENKO, SK
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1993, 14 (1-3) : 687 - 689
  • [34] CMOS monolithic metal-oxide gas sensor microsystems
    Barrettino, D
    Graf, M
    Taschini, S
    Hafizovic, S
    Hagleitner, C
    Hierlemann, A
    [J]. IEEE SENSORS JOURNAL, 2006, 6 (02) : 276 - 286
  • [35] A tiny gas-sensor system based on 1D photonic crystal
    Bouzidi, A.
    Bria, D.
    Akjouj, A.
    Pennec, Y.
    Djafari-Rouhani, B.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2015, 48 (49)
  • [36] Analog signal-selector circuit for quick gas detection from gas-sensor arrays
    AbdelAtyZohdy, HS
    ElLicy, FA
    [J]. 38TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, PROCEEDINGS, VOLS 1 AND 2, 1996, : 509 - 513
  • [37] Improvement of a Real Gas-Sensor for the Origin of Methane Selectivity Degradation by µ-XAFS Investigation
    Takahiro Wada
    Naoyoshi Murata
    Takuya Suzuki
    Hiromitsu Uehara
    Hiroaki Nitani
    Yasuhiro Niwa
    Motohiro Uo
    Kiyotaka Asakura
    [J]. Nano-Micro Letters, 2015, 7 : 255 - 260
  • [38] Measurement of the perceived odour intensity of building materials with multi gas-sensor systems
    Bitter, F
    Müller, D
    [J]. INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 26 - 30
  • [39] Synthesis and properties of multipod-shaped ZnO nanorods for gas-sensor applications
    T. Gao
    T.H. Wang
    [J]. Applied Physics A, 2005, 80 : 1451 - 1454
  • [40] Study to increase the sensitivity of QCM gas-sensor coated with plasma polymerization film
    Han, DS
    Kurosawa, S
    Aizawa, H
    Yoshimoto, M
    Park, JY
    Chang, SM
    [J]. MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2001, 371 : 411 - 414