Evaluation of the Analytical Performance of the Modified Enterprise Point-of-Care Blood Gas and Electrolyte Analyzer in a Pediatric Hospital

被引:2
|
作者
Agarwal, Shweta [1 ]
Shafi, Rabia [1 ]
Edwards, Rachel M. [2 ]
Collymore, Laura [2 ]
Devaraj, Sridevi [1 ,2 ]
机构
[1] Baylor Coll Med, Houston, TX 77030 USA
[2] Texas Childrens Hosp, 6621 Fannin St, Houston, TX 77030 USA
来源
POINT OF CARE | 2014年 / 13卷 / 04期
关键词
EPOC; blood gas; point of care; electrolyte; evaluation;
D O I
10.1097/POC.0000000000000036
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Arterial blood gas testing is an essential component that directs the evaluation of a patient's general condition, especially in the emergent setting. We evaluated the analytical performance of the modified Enterprise point-of-care (EPOC) blood gas and electrolyte analyzer system with respect to precision and accuracy and compared our results with those obtained using the point-of-care i-STAT method and the criterion standard ABL 835 Radiometer blood gas analyzer in a pediatric hospital. Evaluation studies were performed as per the Clinical Laboratory Standards Institute guidelines and included intra-assay and interassay precision and accuracy, linearity, and concordance analyses with i-STAT and ABL 835 Radiometer. Intra-assay and interassay coefficient of variation for each analyte was calculated and was less than 6% for all analytes in the ranges tested including pH, PO2, PCO2, Na+, K+, Ca2+, glucose, lactate, and hematocrit, Cl-, and creatinine. All of the analytes were linear across the reportable range. For the methods comparison of EPOC system with the i-STAT method, using 40 samples, the correlation coefficients were r > 0.94 for all analytes with the exception of Ca2+ (r = 0.61). For the methods comparison of EPOC system with the criterion standard ABL 835 Radiometer on 40 samples, the correlation coefficients were higher than 0.97 for all analytes with the exception of hematocrit and hemoglobin (r = 0.8). Thus, in our pediatric hospital setting, the EPOC system showed excellent precision and accuracy and compared favorably with the i-STAT and ABL 835 Radiometer assay results. These findings, together with the low cost, room temperature storage of test cards and availability of metabolites such as lactate, glucose, and creatinine along with the wireless connectivity of the EPOC system, provide an operational advantage over other point-of-care blood gas analyzers currently available.
引用
收藏
页码:132 / 136
页数:5
相关论文
共 50 条
  • [21] Method validation of GEM® 4000 blood gas analyzer for point-of-care testing
    Martinez Sanchez, L. M.
    Lafuente Muro, S.
    Castillo Ribelles, L.
    Martinez Casademont, M.
    [J]. CLINICA CHIMICA ACTA, 2019, 493 : S765 - S765
  • [22] Point-of-care determination of neonatal bilirubin with the blood gas analyzer RapidLab 1265
    Mielsch, Caroline
    Zimmermann, Andrea
    Wagner, Dieter
    Matthes, Bianca
    Schlebusch, Harald
    Luppa, Peter B.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) : 1455 - 1461
  • [23] Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish
    Harrenstien, LA
    Tornquist, SJ
    Miller-Morgan, TJ
    Fodness, BG
    Clifford, KE
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 226 (02): : 255 - 265
  • [24] Analytical performance evaluation of bioactive adrenomedullin on point-of-care platform
    Joshi, Netra
    Loeffler, Julia
    Szczesna, Karolina
    Do, Tyler
    Vu, Minh
    Cobb, Jared
    Ngo, Huy
    Nguyen, John
    Carbone, Vincenzo
    Bergmann, Deborah
    Shin, Elizabeth
    Hartmann, Tobias
    Gruson, Damien
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (01) : E13 - E16
  • [25] The evaluation of analytical performance of the precision G™ point-of-care glucometer
    Solnica, B
    Naskalski, JW
    Sieradzki, J
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (12) : 1283 - 1286
  • [26] Simultaneous point-of-care testing of blood lipid profile and glucose: Performance evaluation of the GCare Lipid Analyzer
    Kim, Ha Nui
    Yoon, Soo-Young
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (12)
  • [27] Performance evaluation of the Precision™ PCx™ point-of-care blood glucose analyzer using discriminant ratio methodology
    Deyi, VYM
    Philippe, M
    Alexandre, KC
    Nayer, PD
    Hermans, MP
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2002, 40 (10) : 1052 - 1055
  • [28] Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes
    Jain A.
    Subhan I.
    Joshi M.
    [J]. International Journal of Emergency Medicine, 2009, 2 (2) : 117 - 120
  • [29] Analytical performance characteristics of the i-SmartCare 10 analyzer for point-of-care testing
    Kim, S.
    Oh, J.
    Park, H.
    [J]. CLINICA CHIMICA ACTA, 2022, 530 : S101 - S101
  • [30] Analytical evaluation of i-STAT portable clinical analyzer for blood gas and electrolyte analyses in pediatric samples.
    Murthy, JN
    Hicks, JM
    Soldin, SJ
    [J]. CLINICAL CHEMISTRY, 1996, 42 (06) : 198 - 198