Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish

被引:60
|
作者
Harrenstien, LA
Tornquist, SJ
Miller-Morgan, TJ
Fodness, BG
Clifford, KE
机构
[1] Oregon Zoo, Portland, OR 97221 USA
[2] Oregon State Univ, Coll Vet Med, Dept Biomed Sci, Corvallis, OR 97331 USA
[3] Oregon Coast Aquarium, Newport, OR 97365 USA
[4] Oregon State Univ, Oregon Extens Sea Grant, Hatfield Marine Sci Ctr, Newport, OR 97365 USA
关键词
D O I
10.2460/javma.2005.226.255
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To compare values of blood parameters in rockfish obtained by use of a point-of-care portable blood analyzer with values determined by a veterinary diagnostic laboratory, calculate reference ranges for various blood parameters in black rockfish, and compare values of blood parameters in clinically normal fish with those of fish with clinical abnormalities. Design-Prospective study. Animals-41 captive adult black rockfish (Sebastes melanops) and 4 captive adult blue rockfish (Sebastes mystinus). Procedure-Rockfish were anesthetized with tricaine methanesulfonate for collection of blood samples. Heparinized blood samples were immediately analyzed with a point-of-care analyzer. Blood sodium, potassium, chloride, urea nitrogen, and glucose concentrations; Hct; pH; partial pressure of carbon dioxide; total carbon dioxide concentration; bicarbonate concentration; base excess; and hemoglobin concentration were determined. A microhematocrit technique was used to determine PCV, and a refractometer was used to estimate total plasma protein concentration. Paired heparinized blood samples were transported to a veterinary diagnostic laboratory for analyses. Results-Data obtained with the point-of-care analyzer were reproducible; however, values for most blood parameters were significantly different from those obtained by the veterinary diagnostic laboratory. Fish with poor body condition had several blood parameter values that were lower than corresponding values in clinically normal fish. Conclusions and Clinical Relevance-Point-of-care blood analyses may prove useful in rockfish. Point-of-care data for a large number of clinically normal fish must be obtained for reference ranges to be calculated, and further assessments of clinically abnormal fish are necessary to determine the relevance of the data.
引用
收藏
页码:255 / 265
页数:11
相关论文
共 50 条
  • [1] Evaluation of a whole blood point-of-care coagulation analyzer in dogs
    Conroy, Elizabeth M.
    Lyons, Bridget M.
    Koenig, Amie
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024,
  • [2] Evaluation of a Point-of-Care Blood Analyzer for Use in Determination of Select Hematological Indices in the Seminole Killifish
    DiMaggio, Matthew A.
    Ohs, Cortney L.
    Petty, B. Denise
    [J]. NORTH AMERICAN JOURNAL OF AQUACULTURE, 2010, 72 (03) : 261 - 268
  • [3] Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
    Zhu, Huiqing
    Huang, Zhifeng
    Huang, Huimin
    Wang, Caiyou
    Wu, Liting
    Lin, Runpei
    Sun, Baoqing
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (181):
  • [4] Evaluation of the Element point-of-care blood gas analyzer for use in horses
    Krueger, Clarisa R.
    Hackett, Eileen S.
    Hess, Ann M.
    Mama, Khursheed R.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2020, 30 (03) : 279 - 285
  • [5] Evaluation of the Alinity hq Automated Hematologic Analyzer and Determination of Reference Ranges for Novel Red Blood Cell Parameters
    Kim, Seon Young
    Kim, Jimyung
    Kwon, Gye Cheol
    [J]. ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2023, 53 (04): : 653 - 660
  • [6] Point-of-care determination of neonatal bilirubin with the blood gas analyzer RapidLab 1265
    Mielsch, Caroline
    Zimmermann, Andrea
    Wagner, Dieter
    Matthes, Bianca
    Schlebusch, Harald
    Luppa, Peter B.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) : 1455 - 1461
  • [7] Point-of-care, portable microfluidic blood analyzer system
    Maleki, Teimour
    Fricke, Todd
    Quesenberry, J. T.
    Todd, Paul W.
    Leary, James F.
    [J]. MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS X, 2012, 8251
  • [8] Clinical investigation of a point-of-care blood ammonia analyzer
    Goggs, Robert
    Serrano, Sergio
    Szladovits, Balazs
    Keir, Iain
    Ong, Ryan
    Hughes, Dez
    [J]. VETERINARY CLINICAL PATHOLOGY, 2008, 37 (02) : 198 - 206
  • [9] Clinical evaluation of a new point-of-care blood gas analyzer, the ''IRMA system''
    Ozaki, M
    Morioka, N
    Matsukawa, T
    Atarashi, K
    Sessler, DI
    Suzuki, H
    [J]. ANESTHESIOLOGY, 1997, 87 (03) : A428 - A428
  • [10] Use of a point-of-care portable blood analyzer for evaluation of blood gas analytes and select physiologic parameters in the American flamingo (Phoenicopterus ruber)
    Gardhouse S.
    Eshar D.
    [J]. Comparative Clinical Pathology, 2016, 25 (1) : 161 - 164