POLYVINYL-CHLORIDE) MATRIX MEMBRANE URANYL ION-SELECTIVE ELECTRODES BASED ON CYCLIC AND ACYCLIC NEUTRAL CARRIER SENSORS

被引:43
|
作者
JOHNSON, S
MOODY, GJ
THOMAS, JDR
KOHNKE, FH
STODDART, JF
机构
[1] UNIV COLL CARDIFF,SCH CHEM & APPL CHEM,POB 912,CARDIFF CF1 3TB,WALES
[2] UNIV SHEFFIELD,DEPT CHEM,SHEFFIELD S3 7HF,S YORKSHIRE,ENGLAND
关键词
D O I
10.1039/an9891401025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:1025 / 1028
页数:4
相关论文
共 50 条
  • [21] ION-SELECTIVE ELECTRODES BASED ON NEUTRAL CARRIERS AND REVERSIBLE WITH RESPECT TO ORGANIC CATIONS - PLASTICIZED POLYVINYL-CHLORIDE MEMBRANE ELECTRODES BASED ON PHOSPHORYL-CONTAINING PODANDS FOR THE DETERMINATION OF GUANIDINIUM IONS
    NEMILOVA, MY
    SHVEDENE, NV
    FILIMONOVA, VL
    PLETNEV, IV
    BAULIN, VE
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 49 (04) : 378 - 381
  • [22] LIFE TIME OF NEUTRAL CARRIER BASED ION-SELECTIVE LIQUID-MEMBRANE ELECTRODES
    OESCH, U
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (04) : 692 - 700
  • [23] CHLORIDE-SELECTIVE ELECTRODES BASED ON A POLYVINYL-CHLORIDE) MATRIX MEMBRANE AND THEIR APPLICATION TO BLOOD-SERUM MEASUREMENTS
    MIYAGI, H
    KAWANA, H
    TAKATA, Y
    SIMON, W
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1979, (APR): : 206 - 206
  • [24] APPLIED POTENTIAL AND RADIOTRACER STUDIES ON POLYVINYL-CHLORIDE) MATRIX ION-SELECTIVE ELECTRODE MEMBRANES
    DOYLE, B
    MOODY, GJ
    THOMAS, JDR
    [J]. TALANTA, 1982, 29 (07) : 609 - 614
  • [25] ION-SELECTIVE ELECTRODES MADE FROM LIQUID ION-EXCHANGE MEMBRANES TRAPPED IN POLYVINYL-CHLORIDE)
    MOODY, GJ
    THOMAS, JDR
    [J]. CHEMISTRY & INDUSTRY, 1974, (16) : 644 - 647
  • [26] SalphenH2 as a neutral carrier for the uranyl ion-selective PVC membrane sensor
    Department of Chemistry, Research Institute of Natural Sciences, Gyeongsang National University, Chinju 660-701, Korea, Republic of
    [J]. Bull. Korean Chem. Soc., 2006, 6 (899-902):
  • [27] SalphenH2 as a neutral carrier for the uranyl ion-selective PVC membrane sensor
    Kim, Dong Wan
    Park, Kyeong-Won
    Yang, Mi-Hyi
    Kim, Jineun
    Lee, Shim Sung
    Kim, Jae Sang
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2006, 27 (06): : 899 - 902
  • [28] A TRICHLOROMERCURATE(II) ION-SELECTIVE ELECTRODE BASED ON THE TETRADECYLPHOSPHONIUM SALT IN POLYVINYL-CHLORIDE
    KOPYTIN, AV
    GABORKLATSMANYI, P
    IZVEKOV, VP
    PUNGOR, E
    YAGODIN, GA
    [J]. ANALYTICA CHIMICA ACTA, 1983, 148 (APR) : 35 - 40
  • [29] RESPONSE-TIME STUDIES ON NEUTRAL CARRIER ION-SELECTIVE MEMBRANE ELECTRODES
    LINDNER, E
    TOTH, K
    PUNGOR, E
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1978, 50 (12) : 1627 - 1631
  • [30] GAS SENSORS BASED ON ION-SELECTIVE POLYMER MEMBRANE ELECTRODES
    MEYERHOFF, ME
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 20 - ANYL