SalphenH2 as a neutral carrier for the uranyl ion-selective PVC membrane sensor

被引:0
|
作者
Kim, Dong Wan
Park, Kyeong-Won
Yang, Mi-Hyi
Kim, Jineun
Lee, Shim Sung
Kim, Jae Sang [1 ]
机构
[1] Gyeongsang Natl Univ, Dept Chem, Chinju 660701, South Korea
[2] Gyeongsang Natl Univ, Res Inst Nat Sci, Chinju 660701, South Korea
来源
关键词
uranyl ion sensor; potentiometry; PVC membrane; salphenH(2) ionophore;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The complexation of N,N'-4,5-(ethylenedioxy)benzenebis(salicylideneimine), (salphenH(2)) with uranyl ion was studied in acetonitrile solution spectrophtometrically, and the formation constant of the resulting 1 : 1 complex was evaluated. The salphenH(2) ligand was used as an ionophore in plasticized poly(vinyl chloride) (PVC) matrix membrane sensor for uranyl ion. The prepared sensors exhibited a near Nernstian response, 28.0-30.9 mV/decade for uranyl ion over the concentration range 1.0 x 10(-2) to 1.0 X 10(-6) M with a limit of detection of 3.2 x 10(-7) M. The proposed electrode could be used at a working pH range of 1.5-4.0.
引用
收藏
页码:899 / 902
页数:4
相关论文
共 50 条
  • [1] SalphenH2 as a neutral carrier for the uranyl ion-selective PVC membrane sensor
    Department of Chemistry, Research Institute of Natural Sciences, Gyeongsang National University, Chinju 660-701, Korea, Republic of
    [J]. Bull. Korean Chem. Soc., 2006, 6 (899-902):
  • [2] Selective uranyl ion detection by polymeric ion-selective electrodes based on salphenH2 derivatives
    Kim, Dong Wan
    Park, Kyeong-Won
    Yang, Mi-Hyi
    Kim, Tae Ho
    Mahajan, Rakesh Kumar
    Kim, Jae Sang
    [J]. TALANTA, 2007, 74 (02) : 223 - 228
  • [3] Novel PVC membrane uranyl ion-selective sensor
    Saleh, MB
    Soliman, EM
    Gaber, AAA
    Ahmed, SA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 199 - 205
  • [4] Copper Ion Selective Membrane Electrode Based on Bis(salphenH2) Derivatives
    Lee, Chaegyung
    Kim, Dong Wan
    Kim, Junghwan
    Yang, Mi-Hyi
    Choi, Myong Yong
    Kim, Jae Sang
    [J]. SENSOR LETTERS, 2010, 8 (02) : 297 - 302
  • [5] PVC membrane cesium ion-selective sensor based on cephalexin antibiotic
    Saleh, MB
    Hassan, SSM
    Gaber, AAA
    Kream, NAA
    [J]. ANALYTICAL LETTERS, 2003, 36 (11) : 2367 - 2377
  • [6] POLYVINYL-CHLORIDE) MATRIX MEMBRANE URANYL ION-SELECTIVE ELECTRODES BASED ON CYCLIC AND ACYCLIC NEUTRAL CARRIER SENSORS
    JOHNSON, S
    MOODY, GJ
    THOMAS, JDR
    KOHNKE, FH
    STODDART, JF
    [J]. ANALYST, 1989, 114 (09) : 1025 - 1028
  • [7] URANYL ION-SELECTIVE OPTODE BASED ON NEUTRAL IONOPHORES
    LERCHI, M
    REITTER, E
    SIMON, W
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 348 (04): : 272 - 276
  • [8] NONCYCLIC POLYETHERS CONTAINING SULFUR-ATOMS - A NOVEL TYPE OF NEUTRAL CARRIER FOR ION-SELECTIVE PVC MEMBRANE ELECTRODES
    SUGIHARA, H
    OKADA, T
    HIRATANI, K
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1985, (14) : 957 - 958
  • [9] NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODES
    AMMANN, D
    MORF, WE
    ANKER, P
    MEIER, PC
    PRETSCH, E
    SIMON, W
    [J]. ION-SELECTIVE ELECTRODE REVIEWS, 1983, 5 (01): : 3 - 92
  • [10] THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE
    Revenco, Mihail
    Martin, Mariana
    Abu Dayyih, Waell
    [J]. CHEMISTRY JOURNAL OF MOLDOVA, 2010, 5 (01): : 73 - 77