CONCURRENT TREATMENT PLANNING FOR OUTPATIENT HIGH-DOSE-RATE PROSTATE TEMPLATE IMPLANTS

被引:41
|
作者
EDMUNDSON, GK
RIZZO, NR
TEAHAN, M
BRABBINS, D
VICINI, FA
MARTINEZ, A
机构
[1] Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI 48073
关键词
PROSTATE CANCER; IMPLANTS; HDR; TREATMENT PLANNING; ULTRASOUND GUIDANCE;
D O I
10.1016/0360-3016(93)90546-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Since November of 1991, we have treated locally advanced (B2-C) prostate cancer using external beam radiotherapy integrated with outpatient high dose rate interstitial implant boost as part of a Phase II clinical trial. This required (a) rapid, automated planning; (b) incorporation of image data and (c) dose optimization. Methods and Materials: A treatment planning system was designed which integrates imaging and needle guidance with source reconstruction and dose display. All components of treatment planning (reconstruction, optimization, dose prescription, dose display) are largely automated. A rectal reference point was defined which was reproducible and easily verified. No pretreatment planning was required. Results: As of November 1992, 83 treatments were delivered using this system. Intra-operative treatment decisions were made possible due to the speed and ease of interpretation of the system. The system has proven satisfactory in the operating room. Rectal doses were calculated for all patients, and ranged from 35-79% of the prescribed dose, with a mean of 58%. The first echelon of a Phase II escalating dose trial has been completed, with 22 patients treated over a period of 1 year. Conclusion: Outpatient high dose rate brachytherapy appears to be a practical means of boosting locally advanced prostate cancer patients. Rapid treatment planning is possible incorporating on-line ultrasound images to allow immediate dose optimization to be performed during and after implant placement.
引用
收藏
页码:1215 / 1223
页数:9
相关论文
共 50 条
  • [21] Biological Planning for High-Dose-Rate Brachytherapy: Application to Cervical Cancer Treatment
    Lee, Eva K.
    Yuan, Fan
    Templeton, Alistair
    Yao, Rui
    Kiel, Krystyna
    Chu, James C. H.
    [J]. INTERFACES, 2013, 43 (05) : 462 - 476
  • [22] High-Dose-Rate Brachytherapy in the Curative Treatment of Patients With Localized Prostate Cancer
    Pisansky, Thomas M.
    Gold, Douglas G.
    Furutani, Keith M.
    Macdonald, O. Kenneth
    McLaren, Robert H.
    Mynderse, Lance A.
    Wilson, Torrence M.
    Hebl, James R.
    Choo, Richard
    [J]. MAYO CLINIC PROCEEDINGS, 2008, 83 (12) : 1364 - 1372
  • [23] Deep reinforcement learning for treatment planning in high-dose-rate cervical brachytherapy
    Pu, Gang
    Jiang, Shan
    Yang, Zhiyong
    Hu, Yuanjing
    Liu, Ziqi
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 94 : 1 - 7
  • [24] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    [J]. BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [25] Rectum dose reduction and individual treatment plan optimization for high-dose-rate prostate brachytherapy
    Boelling, Tobias
    Moustakis, Christos
    Elsayed, Hassan
    Mueller, Stefan-Bodo
    Weining, Christoph
    Reinartz, Gabriele
    Ernst, Iris
    Willich, Normann
    Koenemann, Stefan
    [J]. BRACHYTHERAPY, 2007, 6 (04) : 280 - 285
  • [26] Developing a High-Dose-Rate Prostate Brachytherapy Program
    Waring, Jayne
    Gosselin, Tracy
    [J]. CLINICAL JOURNAL OF ONCOLOGY NURSING, 2010, 14 (02) : 199 - 205
  • [27] High-dose-rate versus low-dose-rate monotherapy in the treatment of localized prostate cancer - The case for high-dose-rate monotherapy: An up and coming treatment option for low-risk prostate cancer - Point
    Sylvester, John E.
    [J]. BRACHYTHERAPY, 2006, 5 (01) : 1 - 4
  • [28] High-dose-rate brachytherapy as monotherapy in prostate cancer
    Rebecca Kelsey
    [J]. Nature Reviews Urology, 2015, 12 (7) : 359 - 359
  • [29] 3D CT-based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance
    Department of Human Oncology, University of Wisconsin, Madison, WI, United States
    不详
    [J]. 1600, 1224-1228 (July 15, 2004):
  • [30] 3D CT-based high-dose-rate breast brachytherapy implants: Treatment planning and quality assurance
    Das, RK
    Patel, R
    Shah, H
    Odau, H
    Kuske, RR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1224 - 1228