Rectum dose reduction and individual treatment plan optimization for high-dose-rate prostate brachytherapy

被引:3
|
作者
Boelling, Tobias [1 ]
Moustakis, Christos [1 ]
Elsayed, Hassan [1 ]
Mueller, Stefan-Bodo [1 ]
Weining, Christoph [2 ]
Reinartz, Gabriele [1 ]
Ernst, Iris [1 ]
Willich, Normann [1 ]
Koenemann, Stefan [1 ]
机构
[1] Univ Hosp Munster, Dept Radiotherapy, D-48129 Munster, Germany
[2] Univ Hosp Munster, Dept Urol, D-48129 Munster, Germany
关键词
high-dose-rate brachytherapy; prostate; treatment plan optimization; rectum position;
D O I
10.1016/j.brachy.2007.06.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Different doses and techniques used in high-dose-rate (HDR) prostate brachytherapy make it difficult to define universal quality parameters. The aim of this study was to develop individual, objective parameters for the evaluation of an HDR brachytherapy plan for prostate radiation. METHODS: Fifty-three patients who received an HDR brachytherapy boost after external radiation were analyzed in this study. Brachytherapy was performed with a 192 It source after ultrasound-guided, transperineal metal needle application followed by removal of the ultrasound probe to reduce organ dose levels at the anterior rectum wall. The rectum and prostate locations as well as the dose at the anterior rectum wall were estimated under the anatomical conditions of HDR prostate brachytherapy. The doses at the organs at risk (rectum and urethra) were analyzed for several parameters, which were compared to values of former patients before the start of treatment. In cases of major deviations, modifications of the treatment plan were performed before starting the treatment. RESULTS: Deflating of the water balloon led to an increase of the space between the anterior rectal wall and the dorsal margin of the prostate (mean, 6 mm; 1-10 mm). The dose of the introduced "virtual rectum," represented by the ventral surface of the ultrasound probe, in the treatment plan correlated to dose measurements in the rectum. Pretreatment evaluation and comparison of the established individual quality parameters led in two cases to a treatment plan modification. CONCLUSIONS: This method allows a fast and objective individual brachytherapy treatment plan evaluation and improvement. (c) 2007 American Brachytherapy Society. All rights reserved.
引用
收藏
页码:280 / 285
页数:6
相关论文
共 50 条
  • [1] Interactive Treatment Plan Optimization of High-Dose-Rate Brachytherapy for Gynecological Cancer
    Liu, Huan
    Shen, Chenyang
    Klages, Peter
    Yang, Ming
    Albuquerque, Kevin
    Wu, Zhen
    Li, Junli
    Jia, Xun
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E573 - E574
  • [2] Monotherapeutic high-dose-rate brachytherapy for prostate cancer: A dose reduction trial
    Yoshioka, Yasuo
    Konishi, Koji
    Suzuki, Osamu
    Nakai, Yasutomo
    Isohashi, Fumiaki
    Seo, Yuji
    Otani, Yuki
    Koizumi, Masahiko
    Yoshida, Ken
    Yamazaki, Hideya
    Nonomura, Norio
    Ogawa, Kazuhiko
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 110 (01) : 114 - 119
  • [3] Comparison of dose and catheter optimization algorithms in prostate high-dose-rate brachytherapy
    Poulin, Eric
    Varfalvy, Nicolas
    Aubin, Sylviane
    Beaulieu, Luc
    [J]. BRACHYTHERAPY, 2016, 15 (01) : 102 - 111
  • [4] Sensitivity of dose-volume indices to computation settings in high-dose-rate prostate brachytherapy treatment plan evaluation
    van der Meer, Marjolein C.
    Bosman, Peter A. N.
    Pieters, Bradley R.
    Niatsetski, Yury
    van Wieringen, Niek
    Alderliesten, Tanja
    Bel, Arjan
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (04): : 66 - 74
  • [5] High-dose-rate brachytherapy as monotherapy for prostate cancer
    Demanes, D. Jeffrey
    Ghilezan, Michel I.
    [J]. BRACHYTHERAPY, 2014, 13 (06) : 529 - 541
  • [6] Treatment patterns of high-dose-rate and low-dose-rate brachytherapy as monotherapy for prostate cancer
    Barnes, Justin
    Kennedy, William R.
    Fischer-Valuck, Benjamin W.
    Baumann, Brian C.
    Michalski, Jeff M.
    Gay, Hiram A.
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (04) : 320 - 328
  • [7] Developing a High-Dose-Rate Prostate Brachytherapy Program
    Waring, Jayne
    Gosselin, Tracy
    [J]. CLINICAL JOURNAL OF ONCOLOGY NURSING, 2010, 14 (02) : 199 - 205
  • [8] Hyaluronate gel injection for rectum dose reduction in gynecologic high-dose-rate brachytherapy: initial Japanese experience
    Kashihara, Tairo
    Murakami, Naoya
    Tselis, Nikolaos
    Kobayashi, Kazuma
    Tsuchida, Keisuke
    Shima, Satoshi
    Masui, Koji
    Yoshida, Ken
    Takahashi, Kana
    Inaba, Koji
    Umezawa, Rei
    Igaki, Hiroshi
    Ito, Yoshinori
    Kato, Tomoyasu
    Uno, Takashi
    Itami, Jun
    [J]. JOURNAL OF RADIATION RESEARCH, 2019, 60 (04) : 501 - 508
  • [9] Low-dose-rate or high-dose-rate brachytherapy in treatment of prostate cancer - between options
    Skowronek, Janusz
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) : 33 - 41
  • [10] High-dose-rate brachytherapy as monotherapy in prostate cancer
    Rebecca Kelsey
    [J]. Nature Reviews Urology, 2015, 12 (7) : 359 - 359