COMPLICATIONS OF NONRIGID FIXATION OF MANDIBULAR ANGLE FRACTURES

被引:79
|
作者
PASSERI, LA
ELLIS, E
SINN, DP
机构
[1] UNIV TEXAS,SW MED CTR,DIV ORAL & MAXILLOFACIAL SURG,5323 HARRY HINES BLVD,DALLAS,TX 75235
[2] UNIV ESTADUAL CAMPINAS,FAC ODONTOL PIRACICABA,BR-13100 CAMPINAS,SP,BRAZIL
关键词
D O I
10.1016/S0278-2391(10)80350-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This retrospective study analyzed complications in 96 patients with 99 mandibular angle fractures treated during a 3-year period with either closed reduction or nonrigid means of fixation combined with maxillomandibular fixation. An overall complication rate of 17% occurred. Infection was the most common complication, occurring in 17 fractures. Thirteen fractures had infection as the only complication; in the remaining four patients, infection was combined with malunion/malocclusion. The results of this study show that mandibular angle fractures in an innercity population are associated with a high incidence of postsurgical complications. © 1993, American Association of Oral and Maxillofacial Surgeons. All rights reserved.. All rights reserved.
引用
收藏
页码:382 / 384
页数:3
相关论文
共 50 条
  • [21] Biomechanical evaluation of new fixation devices for mandibular angle fractures
    Wittenberg, JM
    Mukherjee, DP
    Smith, BR
    Kruse, RN
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 26 (01) : 68 - 73
  • [22] MANDIBULAR RANGE OF MOTION WITH RIGID NONRIGID FIXATION
    ARAGON, SB
    VANSICKELS, JE
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1987, 63 (04): : 408 - 411
  • [23] COST-EFFECTIVENESS ANALYSIS OF OPEN REDUCTION NONRIGID FIXATION AND OPEN REDUCTION RIGID FIXATION TO TREAT MANDIBULAR FRACTURES
    DODSON, TB
    PFEFFLE, RC
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1995, 80 (01): : 5 - 11
  • [24] Reply: Internal Fixation of Mandibular Angle Fractures: A Meta-Analysis
    Regev, Eran
    Fialkov, Jeffery A.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 127 (01) : 480 - 481
  • [25] One- or two-plate fixation of mandibular angle fractures?
    Schierle, HP
    Schmelzeisen, R
    Rahn, B
    Pytlik, C
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1997, 25 (03) : 162 - 168
  • [26] One miniplate compared with two in the fixation of isolated fractures of the mandibular angle
    Al-moraissi, E. A.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2015, 53 (08): : 690 - 698
  • [27] AUXILIARY DEVICES FOR OPEN REDUCTION AND FIXATION OF DISPLACED MANDIBULAR ANGLE FRACTURES
    HALLING, F
    MERTEN, HA
    LUHR, HG
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (11) : 1247 - 1250
  • [28] Discussion: Internal Fixation of Mandibular Angle Fractures: A Meta-Analysis
    Ellis, Edward, III
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (06) : 1761 - 1762
  • [29] A computer study of biodegradable plates for internal fixation of mandibular angle fractures
    Tams, J
    Van Loon, JP
    Otten, B
    Bos, RRM
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (04) : 404 - 407
  • [30] Biomechanical analysis of titanium fixation plates and screws in mandibular angle fractures
    Atik, F.
    Atac, M. S.
    Ozkan, A.
    Kilinc, Y.
    Arslan, M.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2016, 19 (03) : 386 - 390