A computer study of biodegradable plates for internal fixation of mandibular angle fractures

被引:45
|
作者
Tams, J
Van Loon, JP
Otten, B
Bos, RRM
机构
[1] Univ Groningen, Dept Med Physiol, Groningen, Netherlands
[2] Univ Groningen Hosp, Dept Oral & Maxillofacial Surg, Groningen, Netherlands
关键词
D O I
10.1053/joms.2001.21877
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This computer-based study was performed to determine the suitability of small biodegradable plate systems for mandibular angle fractures. Materials and Methods: In a 3-dimensional computer model of the mandible, fracture mobility and plate strain were calculated for bite forces applied on 13 bite points on the dental arch. The angle fracture was fixed with 2 polylactide (PLA) midiplates or with 2 PLA maxiplates. The first plate was positioned buccally on the external oblique ridge. Two positions of the second plate were studied: halfway up the height of the mandible or on the lower border. Maximum fracture mobility was set at a limit of 150 mum to enable undisturbed fracture healing. Maximum plate strain was set at the yield strain of PLA. Results: Fixation with the PLA maxiplates, with the second plate positioned halfway up the height of the mandible, resulted in fracture mobility below the set limit for all bite points. For the other PLA fixation strategies, fracture mobility exceeded the set Limit. Fixation with the second plate positioned halfway up the height of the mandible generally resulted in less fracture mobility than with the plate positioned on the lower border. The yield strain of PLA was not exceeded in any of the fixation strategies. Conclusions: Based on the computer model. 2 PLA maxiplates are suitable for fixation of mandibular angle fractures. One plate should be positioned buccally on the external oblique ridge, and the other should be positioned halfway up the height of the mandible. (C) 2001 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:404 / 407
页数:4
相关论文
共 50 条
  • [1] A computer study of fracture mobility and strain on biodegradable plates used for fixation of mandibular fractures
    Tams, J
    Otten, B
    van Loon, JP
    Bos, RRM
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (08) : 973 - 981
  • [2] A computer study of fracture mobility and strain of biodegradable plates used for fixation of mandibular fractures
    Iizuka, T
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (08) : 981 - 982
  • [3] Fixation of mandibular fractures with biodegradable plates and screws
    Yerit, KC
    Enislidis, G
    Schopper, C
    Turhani, D
    Wanschitz, F
    Wagner, A
    Watzinger, F
    Ewers, R
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 94 (03): : 294 - 300
  • [4] Application of 2.0 mm Titanium Plates in Rigid Internal Fixation of Mandibular Angle Fractures
    Sabhlok S.
    Waknis P.
    Bhagwat A.
    [J]. Journal of Maxillofacial and Oral Surgery, 2010, 9 (4) : 339 - 343
  • [5] Open Reduction with Internal Fixation of Mandibular Angle Fractures: A Retrospective Study
    Bouchard, Carl
    Mansouri, Masoud
    [J]. JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2017, 83
  • [6] Biomechanical Study in Polyurethane Mandibles of Different Metal Plates and Internal Fixation Techniques, Employed in Mandibular Angle Fractures
    Semeghini Guastaldi, Fernando Pozzi
    Hochuli-Vieira, Eduardo
    Guastaldi, Antonio Carlos
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (06) : 2246 - 2250
  • [7] Are Biodegradable Plates Applicable in Endoscope-Assisted Open Reduction and Internal Fixation of Mandibular Subcondyle Fractures?
    Son, Jang-Ho
    Ha, Jinhee
    Cho, Yeong-Cheol
    Sung, Iel-Yong
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (08) : 1706 - 1715
  • [8] TREATMENT OF MANDIBULAR ANGLE FRACTURES - TRANSORAL INTERNAL WIRE FIXATION
    MARCIANI, RD
    ANDERSON, GE
    GONTY, AA
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1994, 52 (07) : 752 - 756
  • [9] Internal Fixation of Mandibular Angle Fractures: A Meta-Analysis
    Regev, Eran
    Kiss, Jacob S. Shiff Alex
    Fialkov, Jeffrey A.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2010, 125 (06) : 1753 - 1760
  • [10] EVALUATION OF INTERNAL-FIXATION TECHNIQUES FOR MANDIBULAR ANGLE FRACTURES
    SHETTY, V
    BAKER, S
    CAPUTO, A
    BERTOLAMI, C
    [J]. JOURNAL OF DENTAL RESEARCH, 1990, 69 : 297 - 297