STUDY OF HUMAN PRECORNEAL TEAR FILM THICKNESS AND STRUCTURE USING LASER INTERFEROMETRY

被引:1
|
作者
PRYDAL, JI
ARTAL, P
HONG, W
CAMPBELL, FW
机构
[1] INST OPT,MADRID,SPAIN
[2] INST OPHTHALMOL,LONDON WC1H 9QS,ENGLAND
基金
英国惠康基金;
关键词
TEAR FILM; MUCUS; INTERFEROMETRY; CONFOCAL MICROSCOPY; ACETYLCYSTEINE;
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The authors previously found that measurements of precorneal tear film thickness in animals, using laser interferometry and confocal microscopy, were larger than earlier estimates. They proposed that this occurred because optical methods did not disturb film structure and measured full thickness, including mucus. In the present study, tear film thickness was measured in humans. Coherent light was reflected from eyes and formed interference patterns. Thickness was determined from spacing of fringes. Mean thickness in six subjects was 34-45-mu-m, more than four times larger than earlier values. Validity and accuracy of measurements by interferometry were examined in our earlier study using confocal microscopy. Here it provided supportive evidence. Tear film thickness was estimated from optical sections through the corneas of three subjects to be 41-46-mu-m. Mucus content of the film also was examined. Interferometry was used to measure thinning after application of a mucolytic agent. There was no change in thickness after 5 min expsoure to 0.1% (weight/volume) acetylcysteine. Solutions of 20% caused thinning to 11-mu-m, and thickness slowly increased to reach its original values over 40 min. Thus, the film seemed to be composed substantially of mucus, not aqueous fluid. The results also provided evidence that measurements by interferometry did not include underlying epithelium. Earlier nonoptical methods probably did not include the portion of the film that contained mucus. They seem to have greatly underestimated human tear film thickness.
引用
下载
收藏
页码:2006 / 2011
页数:6
相关论文
共 50 条
  • [21] Factors Influencing the Measurement of Tear Film Lipid Layer Thickness with Interferometry
    Finis, D.
    Pischel, N.
    Borrelli, M.
    Schrader, S.
    Geerling, G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2014, 231 (06) : 603 - 610
  • [22] In vivo thickness measurement of the lipid layer and the overall tear film by interferometry
    Bai, Yuqiang
    Nichols, Jason J.
    OPTICS LETTERS, 2019, 44 (10) : 2410 - 2413
  • [23] Evaporation from the human tear film studied by interferometry
    King-Smith, PE
    Fink, BA
    Hill, RM
    LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 3: BASIC SCIENCE AND CLINICAL RELEVANCE, PTS A & B, 2002, 506 : 425 - 429
  • [24] MEASUREMENT OF TEAR FILM THICKNESS USING FLUOROPHOTOMETRY
    YUN, YS
    MCCAREY, BE
    AMOS, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1470 - 1470
  • [25] Measurement of liquid-film thickness by laser interferometry
    Nozhat, WM
    APPLIED OPTICS, 1997, 36 (30): : 7864 - 7869
  • [26] Thin film thickness measurement by double laser interferometry
    Domingo, M.
    Millan, C.
    Satorre, M. A.
    Canto, J.
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION V, PTS 1 AND 2, 2007, 6616 : A6164 - A6164
  • [27] THE MUCUS CONTENT OF THE HUMAN TEAR FILM BY OPTICAL DETERMINATION OF FILM THICKNESS
    PRYDAL, JI
    JOURNAL OF PHYSIOLOGY-LONDON, 1989, 415 : P88 - P88
  • [28] Visualization of the Precorneal Tear Film Using Ultrahigh Resolution Optical Coherence Tomography in Dry Eye
    Cui, Lele
    Wang, Jianhua
    Perez, Victor L.
    Shen, Meixiao
    Yuan, Yimin
    Wang, Michael R.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (04): : 240 - 244
  • [29] Thin film thickness measurement based on laser heterodyne interferometry
    Shi Kai
    Su Junhong
    9TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES (AOMATT 2018): OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2019, 10839
  • [30] Measurement of liquid crystal film thickness using interferometry
    Kossivas, F.
    Kyprianou, A.