PERFORMANCE AND OPTIMIZATION OF A COMBUSTION INTERFACE FOR ISOTOPE RATIO MONITORING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

被引:134
|
作者
MERRITT, DA
FREEMAN, KH
RICCI, MP
STUDLEY, SA
HAYES, JM
机构
[1] INDIANA UNIV,DEPT CHEM,BIOGEOCHEM LABS,BLOOMINGTON,IN 47405
[2] INDIANA UNIV,DEPT GEOL SCI,BIOGEOCHEM LABS,BLOOMINGTON,IN 47405
关键词
D O I
10.1021/ac00110a022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nmol of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O-2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T < 1050 degrees C if gas-phase O-2 is not added. For all compounds tested except CH4, equivalent isotopic results are provided by CuO at 850 degrees C, NiO + O-2 (gas-phase mole fraction, 10(-3)) at 1050 degrees C, and NiO at 1150 degrees C. The combustion interface did not contribute additional analytical uncertainty, thus observed standard deviations of C-13/C-12 ratios were within a factor of 2 of shot-noise limits. For combustion and isotopic analyses of CH4, in which quantitative combustion required T approximate to 950 degrees C, NiO-based systems are preferred, and precision is similar to 2 times lower than that observed for other analytes. Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.
引用
收藏
页码:2461 / 2473
页数:13
相关论文
共 50 条
  • [31] GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY MASS-SPECTROMETRY OF METHYL-ESTER METHOXIME TRIMETHYLSILYL ETHER DERIVATIVES OF THROMBOXANES
    SCHWEER, H
    SEYBERTH, HW
    MEESE, CO
    FURST, O
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 15 (03): : 139 - 142
  • [32] PLASMA AMINO-ACID ANALYSIS BY ISOTOPE RATIO GAS-CHROMATOGRAPHY MASS-SPECTROMETRY COMPUTER TECHNIQUES
    SCHULMAN, MF
    ABRAMSON, FP
    BIOMEDICAL MASS SPECTROMETRY, 1975, 2 (01): : 9 - 14
  • [33] PROTEIN AMINO-ACID-ANALYSIS BY AN ISOTOPE RATIO GAS-CHROMATOGRAPHY MASS-SPECTROMETRY COMPUTER TECHNIQUE
    RAFTER, JJ
    INGELMANSUNDBERG, M
    GUSTAFSSON, JA
    BIOMEDICAL MASS SPECTROMETRY, 1979, 6 (08): : 317 - 324
  • [34] SAMPLE PREPARATION FOR GAS-CHROMATOGRAPHY ISOTOPE RATIO MASS-SPECTROMETRY - AN INVESTIGATION WITH VOLATILE COMPONENTS FROM STRAWBERRIES
    SCHUMACHER, K
    TURGEON, H
    MOSANDL, A
    PHYTOCHEMICAL ANALYSIS, 1995, 6 (05) : 258 - 261
  • [35] DETERMINATION OF POLYSULFIDES IN BLOOD BY GAS-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    KAGE, S
    NAGATA, T
    KUDO, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 564 (01): : 163 - 169
  • [36] THE DETERMINATION OF DIAZEPAM IN SERUM BY GAS-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY - MASS-SPECTROMETRY
    RODGERS, T
    POWEL, B
    VASILIADES, J
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1005 - 1005
  • [37] ANALYSIS OF NATURAL BRASSINOSTEROIDS BY GAS-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    IKEKAWA, N
    TAKATSUTO, S
    KITSUWA, T
    SAITO, H
    MORISHITA, T
    ABE, H
    JOURNAL OF CHROMATOGRAPHY, 1984, 290 (MAY): : 289 - 302
  • [38] A single glucose derivative suitable for gas chromatography/mass spectrometry and gas chromatography/combustion/isotope ratio mass spectrometry
    Jackson, Sarah J.
    Waterhouse, John S.
    Bluck, Leslie J. C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) : 3123 - 3128
  • [39] THE ANALYSIS OF THE C1-C5 COMPONENTS OF NATURAL-GAS SAMPLES USING GAS-CHROMATOGRAPHY COMBUSTION ISOTOPE RATIO MASS-SPECTROMETRY
    BAYLIS, SA
    HALL, K
    JUMEAU, EJ
    ORGANIC GEOCHEMISTRY, 1994, 21 (6-7) : 777 - 785
  • [40] SELECTED REACTION MONITORING DURING GAS-CHROMATOGRAPHY - MASS-SPECTROMETRY OF EICOSANOIDS
    HUGHES, H
    NOWLIN, J
    GASKELL, SJ
    PARR, VC
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 409 - 413