A single glucose derivative suitable for gas chromatography/mass spectrometry and gas chromatography/combustion/isotope ratio mass spectrometry

被引:12
|
作者
Jackson, Sarah J.
Waterhouse, John S.
Bluck, Leslie J. C.
机构
[1] MRC Huma Nutr Res, Elsie Widdowson Lab, Cambridge CB1 9NL, England
[2] Angila Ruskin Univ, Environm Sci Res Ctr, Cambridge CB1 1PT, England
基金
英国医学研究理事会;
关键词
D O I
10.1002/rcm.3195
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The incorporation of stable isotopes improves the assessment of glucose metabolism and, with some researchers using two tracers, H-2-glucose assessed by gas chromatography/mass spectrometry (GC/MS) and C-13-glucose by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS), a common derivative for both is advantageous. The most commonly used derivatives for GC/MS are inappropriate for GC/C/lRMS as additional functional groups dilute the label. We therefore considered the suitability of six derivatives for both GC/MS and GC/C/IRMS. Glucose alkylboronates were prepared by adding the appropriate alkylboronic acid (butyl- or methylboronic acid) in pyridine to desiccated glucose. The derivatisation was completed by reacting this with either (a) acetic anhydride or trifluoroacetic anhydride (acetate derivatives) or (b) bis(trimethylsilyl) trifluoroacetamide BSTFA (TMS derivatives). All six derivatives were assessed using GC/MS and C-13 GC/C/IRMS. Neither TMS derivative exhibited any signal intensity in the molecular ion, although a M-15 ion showed good agreement between experimental and theoretical data and, whilst still low in intensity, could be suitable for isotope work. Similarly, none of the acetate derivatives showed any intensity at the molecular ion although three key fragmentation series were identified. The most attractive sequence, initiated by the loss of 1,2 cyclic boronate, resulted in the main fragment ion of interest, m/z 240, corresponding to the fluorinated methylboronate derivate. Minimal carbon and hydrogen atoms are added to this derivative making it an excellent choice for stable isotope work, while proving suitable for analysis by both GUMS and GC/C/IRMS. Copyright (c) 2007 John Wiley & Sons, Ltd.
引用
收藏
页码:3123 / 3128
页数:6
相关论文
共 50 条
  • [1] Fast gas chromatography combustion isotope ratio mass Spectrometry
    Sacks, Gavin L.
    Zhang, Ying
    Brenna, J. Thomas
    [J]. ANALYTICAL CHEMISTRY, 2007, 79 (16) : 6348 - 6358
  • [2] ARGININE DERIVATIVE SUITABLE FOR MASS SPECTROMETRY AND GAS CHROMATOGRAPHY
    VETTERDI.H
    VETTER, W
    RICHTER, W
    BIEMANN, K
    [J]. EXPERIENTIA, 1968, 24 (04): : 340 - +
  • [3] Validation of pentaacetylaldononitrile derivative for dual 2H gas chromatography/mass spectrometry and 13C gas chromatography/combustion/isotope ratio mass spectrometry analysis of glucose
    Sauvinet, Valerie
    Gabert, Laure
    Qin, Du
    Louche-Pelissier, Corinne
    Laville, Martine
    Desage, Michel
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (23) : 3855 - 3867
  • [4] Calibration and data processing in gas chromatography combustion isotope ratio mass spectrometry
    Zhang, Ying
    Tobias, Herbert J.
    Sacks, Gavin L.
    Brenna, J. Thomas
    [J]. DRUG TESTING AND ANALYSIS, 2012, 4 (12) : 912 - 922
  • [5] Comparison of gas chromatography-mass spectrometry and gas chromatography-combustion-isotope ratio mass spectrometry analysis for in vivo estimates of metabolic fluxes
    Croyal, Mikael
    Bourgeois, Raphaelle
    Ouguerram, Khadija
    Billon-Crossouard, Stephanie
    Aguesse, Audrey
    Nguyen, Patrick
    Krempf, Michel
    Ferchaud-Roucher, Veronique
    Nobecourt, Estelle
    [J]. ANALYTICAL BIOCHEMISTRY, 2016, 500 : 63 - 65
  • [6] Applied gas chromatography coupled to isotope ratio mass spectrometry
    Meier-Augenstein, W
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) : 351 - 371
  • [7] The application of a simple algorithm to isotope ratio measurements by gas chromatography/combustion/isotope ratio mass spectrometry
    Bluck, LJC
    Coward, WA
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2004, 15 (02) : N21 - N24
  • [8] Development of criteria for the detection of adrenosterone administration by gas chromatography-mass spectrometry and gas chromatography-combustion-isotope ratio mass spectrometry for doping control
    Brooker, Lance
    Parr, Maria Kristina
    Cawley, Adam
    Flenker, Ulrich
    Howe, Christopher
    Kazlauskas, Rymantas
    Schaenzer, Wilhelm
    George, Adrian
    [J]. DRUG TESTING AND ANALYSIS, 2009, 1 (11-12) : 587 - 595
  • [9] The use of gas chromatography-mass spectrometry/combustion/isotope ratio mass spectrometry to demonstrate progesterone treatment in bovines
    Janssens, Geert
    Mangelinckx, Sven
    Courtheyn, Dirk
    De Kimpe, Norbert
    Matthijs, Bert
    Le Bizec, Bruno
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1449 : 129 - 140
  • [10] Comprehensive Two-Dimensional Gas Chromatography Combustion Isotope Ratio Mass Spectrometry
    Tobias, Herbert J.
    Sacks, Gavin L.
    Zhang, Ying
    Brenna, J. Thomas
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (22) : 8613 - 8621