DETERMINATIONS OF ORGAN DOSES AND EFFECTIVE DOSE EQUIVALENTS FROM COMPUTED TOMOGRAPHIC EXAMINATION

被引:73
|
作者
NISHIZAWA, K [1 ]
MARUYAMA, T [1 ]
TAKAYAMA, M [1 ]
OKADA, M [1 ]
HACHIYA, J [1 ]
FURUYA, Y [1 ]
机构
[1] NATL INST RADIOL SCI,DIV PHYS,CHIBA 260,JAPAN
来源
BRITISH JOURNAL OF RADIOLOGY | 1991年 / 64卷 / 757期
关键词
ORGAN DOSE MEASUREMENT; EFFECTIVE DOSE EQUIVALENT; COMPUTED TOMOGRAPHY; MEDICAL EXPOSURE;
D O I
10.1259/0007-1285-64-757-20
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The organ or tissue doses were determined with a phantom measurement for 12 types of CT scanners widely used in Japan. Two types of thermoluminescent dosimeters were used for the dose determinations in a Rando woman phantom. The effective dose equivalents recommended by the International Commission on Radiological Protection were calculated using the measured organ or tissue doses. It was found that the CT scanners currently available give quite different organ or tissue doses. When selecting the optimum technical factors for scanning, therefore, it is important to take into consideration the balance of the image quality and the radiation exposure to patients.
引用
收藏
页码:20 / 28
页数:9
相关论文
共 50 条
  • [21] Organ Doses and Effective Doses in Pediatric Radiography: Patient-Dose Survey in Finland
    Kiljunen, T.
    Tietavainen, A.
    Parviainen, T.
    Viitala, A.
    Kortesniemi, M.
    ACTA RADIOLOGICA, 2009, 50 (01) : 114 - U16
  • [22] Aircraft radiation exposure assessment in a radioactive environment: Ambient dose equivalents and effective doses
    Frigi, Felipe L.
    Pazianotto, Mauricio T.
    Federico, Claudio A.
    Andrade, Edson R.
    RADIATION MEASUREMENTS, 2024, 176
  • [23] From the entrance dose to the calculation of organ doses
    Rassow, S
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 327 - 329
  • [24] A PC program for estimating organ dose and effective dose values in computed tomography
    W. A. Kalender
    B. Schmidt
    M. Zankl
    M. Schmidt
    European Radiology, 1999, 9 : 555 - 562
  • [25] A PC program for estimating organ dose and effective dose values in computed tomography
    Kalender, WA
    Schmidt, B
    Zankl, M
    Schmidt, M
    EUROPEAN RADIOLOGY, 1999, 9 (03) : 555 - 562
  • [26] Organ doses, effective dose, and cancer risk estimation from head and neck CT scans
    Kamrani, Samira
    Kasraie, Nima
    Jahangiri, Fatemeh
    Khezerloo, Davood
    Sheikhzadeh, Peyman
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212
  • [27] Methods to Determine Peak Skin Dose and Organ Doses for Computed Tomography Examinations
    de las Heras, H.
    Minniti, R.
    Wilson, S.
    Benevides, L.
    Skopec, M.
    Chakrabarti, K.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] A survey of 14 computed tomography scanners in Greece and 32 scanners in Italy. Examination frequencies dose reference values, effective doses and doses to organs
    Papadimitriou, D
    Perri, A
    Manetou, A
    Molfetas, M
    Panagiotakis, N
    Lyra-Georgosopoulou, M
    Hourdakis, K
    Kottou, S
    Tosi, G
    Origgi, D
    Vigorito, S
    RADIATION PROTECTION DOSIMETRY, 2003, 104 (01) : 47 - 53
  • [29] RADIATION-DOSE FROM COMPUTED TOMOGRAPHIC BODY SCANNING IN CHILDREN - DOSES FROM 7 SCANNERS AND THEIR RELATIONS TO RESOLVING POWER
    BRASCH, RC
    GOODING, CA
    BOYD, DP
    KOROBKIN, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 130 (04) : 795 - 795
  • [30] A METHOD FOR ESTIMATING EMBRYO DOSES RESULTING FROM COMPUTED TOMOGRAPHIC EXAMINATIONS
    PANZER, W
    ZANKL, M
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (742): : 936 - 939