Evaluation of an iterative model-based reconstruction algorithm for low-tube-voltage (80 kVp) computed tomography angiography

被引:21
|
作者
Noel, Peter B. [1 ]
Koehler, Thomas [2 ]
Fingerle, Alexander A. [1 ]
Brown, Kevin M. [3 ]
Zabic, Stanislav [3 ]
Muenzel, Daniela [1 ]
Haller, Bernhard [4 ]
Baum, Thomas [1 ]
Henninger, Martin [1 ]
Meier, Reinhard [1 ]
Rummeny, Ernst J. [1 ]
Dobritz, Martin [1 ]
机构
[1] Tech Univ Munich, Dept Radiol, D-81675 Munich, Germany
[2] Philips Res Labs, D-22335 Hamburg, Germany
[3] Philips Healthcare, Cleveland, OH 44143 USA
[4] Tech Univ Munich, Inst Med Stat & Epidemiol, D-81675 Munich, Germany
关键词
computed tomography; iterative reconstruction; low-tube-current; computed tomography angiography; dose reduction; low-tube-voltage;
D O I
10.1117/1.JMI.1.3.033501
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to investigate the improvement in diagnostic quality of an iterative model-based reconstruction (IMBR) algorithm for low-tube-voltage (80-kVp) and low-tube-current in abdominal computed tomography angiography (CTA). A total of 11 patients were imaged on a 256-slice multidetector computed tomography for visualization of the aorta. For all patients, three different reconstructions from the low-tube-voltage data are generated: filtered backprojection (FBP), IMBR, and a mixture of both IMBR + FBP. To determine the diagnostic value of IMBR-based reconstructions, the image quality was assessed. With IMBRbased reconstructions, image noise could be significantly reduced, which was confirmed by a highly improved contrast-to-noise ratio. In the image quality assessment, radiologists were able to reliably detect more third-order and higher aortic branches in the IMBR reconstructions compared to FBP reconstructions. The effective dose level was, on average, 3.0 mSv for 80-kVp acquisitions. Low-tube-voltage CTAs significantly improve vascular contrast as presented by others; however, this effect in combination with IMBR enabled yet another substantial improvement of diagnostic quality. For IMBR, a significant improvement of image quality and a decreased radiation dose at low-tube-voltage can be reported. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Yanaga, Yumi
    Yamashita, Yasuyuki
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) : 480 - 485
  • [2] Image quality evaluation of iterative model reconstruction on low tube voltage (80 kVp) coronary CT angiography in an animal study
    Hu, Mao-Qing
    Li, Meng
    Liu, Zai-Yi
    Huang, Mei-Ping
    Liu, Hui
    Liang, Chang-Hong
    ACTA RADIOLOGICA, 2016, 57 (02) : 170 - 177
  • [3] Liver Computed Tomography With Low Tube Voltage and Model-Based Iterative Reconstruction Algorithm for Hepatic Vessel Evaluation in Living Liver Donor Candidates
    Hur, Bo Yun
    Lee, Jeong Min
    Joo, Ijin
    Yu, Mi Hye
    Yoon, Jeong Hee
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (03) : 367 - 375
  • [4] A Hybrid Iterative Reconstruction Algorithm That Improves the Image Quality of Low-Tube-Voltage Coronary CT Angiography
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Yonenaga, Kazuchika
    Namimoto, Tomohiro
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) : 1126 - 1131
  • [5] Usefulness of a Low Tube Voltage: Knowledge-Based Iterative Model Reconstruction Algorithm for Computed Tomography Venography
    Iyama, Yuji
    Nakaura, Takeshi
    Iyama, Ayumi
    Kidoh, Masafumi
    Oda, Seitaro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (05) : 811 - 816
  • [6] Coronary Computed Tomographic Angiography at 80 kVp and Knowledge-Based Iterative Model Reconstruction Is Non-Inferior to that at 100 kVp with Iterative Reconstruction
    Lee, Joohee
    Park, Chul Hwan
    Oh, Chi Suk
    Han, Kyunghwa
    Kim, Tae Hoon
    PLOS ONE, 2016, 11 (09):
  • [7] Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction
    Pan, Yu-Ning
    Li, Ai-Jing
    Chen, Zhao-Qian
    Ren, Da-Wei
    Zhang, Jie
    Jiang, Mao-Qing
    Huang, Qiu-Li
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 272 - 276
  • [8] Low-Tube-Voltage 80-kVp Neck CT: Evaluation of Diagnostic Accuracy and Interobserver Agreement
    Wichmann, J. L.
    Kraft, J.
    Noeske, E. -M.
    Bodelle, B.
    Burck, I.
    Scholtz, J. -E.
    Frellesen, C.
    Wagenblast, J.
    Kerl, J. M.
    Bauer, R. W.
    Lehnert, T.
    Vogl, T. J.
    Schulz, B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (12) : 2376 - 2381
  • [9] Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study
    Zheng, Minwen
    Liu, Ying
    Wei, Mengqi
    Wu, Yongjie
    Zhao, Hongliang
    Li, Jian
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : E92 - E99
  • [10] Evaluation of a commercial Model Based Iterative reconstruction algorithm in computed tomography
    Paruccini, Nicoletta
    Villa, Raffaele
    Pasquali, Claudia
    Spadavecchia, Chiara
    Baglivi, Antonia
    Crespi, Andrea
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 : 58 - 70