Method Development and Validation for the Simultaneous Estimation of Rosuvastatin and Amlodipine in Bulk and its Formulation using Reverse-Phase High-Performance Liquid Chromatography

被引:0
|
作者
Boggula, Narender [1 ]
Mulagada, Gowri Manoja [1 ]
Priya, D. K. Shanthi [1 ]
Bakshi, Vasudha [1 ]
Peddapalli, Himabindu [1 ]
机构
[1] Anurag Grp Inst, Sch Pharm, Dept Pharmaceut Chem, Ghatkesar, Telangana, India
关键词
Amlodipine; precision; reverse-phase high-performance liquid chromatography; rosudapin; rosuvastatin; simultaneous estimation;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: High-performance liquid chromatography (HPLC) is basically a highly improved form of column liquid chromatography. Instead of a solvent being allowed to drip through a column under gravity, it is forced through under high pressures of up to 400 atmospheres which makes it much faster. All chromatographic separations including HPLC is based upon the resolution of the sample constituents as per the difference in their relative affinities towards stationary phase and mobile phase used. Aim: A simple, specific, accurate, and precise reverse-phase HPLC method was developed and validated for the estimation of rosuvastatin and amlodipine (Rosudapin) in pharmaceutical dosage form. Materials and Methods: An Aquasil column reversed phase C-18, 5 mu m column having 4.6 mm x 250 mm i. d. in gradient mode, with mobile phase containing HPLC grade acetonitrile: phosphate buffer (pH 3.8): methanol in proportion 30: 60: 10 v/v, was used. The flow rate was 1 ml/min and effluents were monitored at 251 nm using PDA detector. Linearity was observed over a range of 5-25 mu g/mL of rosuvastatin and 2.5-12.5 mu g/mL of amlodipine, respectively. Results and Discussion: The method was validated for linearity, accuracy, precision, limit of detection, limit of quantitation, robustness, and ruggedness. The limit of detection and estimation of analytes was found to be 3.1 mu g/ml and 2.98 mu g/ml, and the limit of quantification of analytes was found to be 102 mu g/ml and 9 mu g/ml, respectively, for rosuvastatin and amlodipine. Conclusion: The proposed method was successfully applied for the quantitative determination of rosuvastatin and amlodipine in pharmaceutical dosage form.
引用
收藏
页码:S1304 / S1309
页数:6
相关论文
共 50 条
  • [31] DESALTING OF NUCLEOTIDES BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NORTHROP, DB
    NEWTON, CJ
    METHODS IN ENZYMOLOGY, 1986, 122 : 155 - 156
  • [32] A reverse-phase, isocratic high-performance liquid chromatography assay for levofloxacin
    Tobin, CM
    Sunderland, J
    White, LO
    MacGowan, AP
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1999, 43 (03) : 434 - 435
  • [33] SIMULTANEOUS DETERMINATIONS OF CINOBUFAGIN AND ITS METABOLITES BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY IN RAT SERUM AND URINE
    ZHANG, LS
    AOKI, K
    YOSHIDA, T
    KUROIWA, Y
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (17): : 3515 - 3530
  • [34] DEVELOPMENT OF REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD AND ITS VALIDATION FOR ESTIMATION OF FORMOTEROL FUMARATE ROTA CAPS
    Ahmed, Siraj
    Jayakar, B.
    Aleem, M. A.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL SCIENCES AND RESEARCH, 2011, 2 (02): : 319 - 324
  • [35] Development of a reverse-phase high-performance liquid chromatography method for analyzing trans-resveratrol in peanut kernels
    Rudolf, JL
    Resurreccion, AVA
    Saalia, FK
    Phillips, RD
    FOOD CHEMISTRY, 2005, 89 (04) : 623 - 638
  • [36] Analytical Method Development and Validation for the Simultaneous Estimation of Abacavir and Lamivudine by Reversed-phase High-performance Liquid Chromatography in Bulk and Tablet Dosage Forms
    Ahmad, Sufiyan Ahmad Raees
    Patil, Lalit
    Usman, Mohammed Rageeb Mohammed
    Imran, Mohammad
    Akhtar, Rashid
    PHARMACOGNOSY RESEARCH, 2018, 10 (01): : 92 - 97
  • [37] Development and validation of a high-performance liquid chromatography method for the estimation of esomeprazole in bulk and tablet dosage form
    Chorage, Trushal V.
    Wankhede, Sagar B.
    Kandekar, Ujjwala Y.
    Nimbalkar, Vinod H.
    Nimje, Hemlata M.
    ARS PHARMACEUTICA, 2023, 64 (03) : 218 - 229
  • [38] Analytical Quality by Design Approach of Reverse-Phase High-Performance Liquid Chromatography of Atorvastatin: Method Development, Optimization, Validation, and the Stability-Indicated Method
    Alruwaili, Nabil K.
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 2021
  • [39] Simultaneous estimation of Rosuvastatin calcium and Ezetimibe in tablet dosage form by reverse phase high performance liquid chromatography
    Sharma, Smita
    Sharma, M. C.
    Kohli, D. V.
    Chaturvedi, S. C.
    OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2010, 4 (02): : 238 - 241
  • [40] Development and Validation of Reverse-Phase High-Performance Liquid Chromatography Method for Estimation of Itraconazole through Hydroxypropyl Methylcellulose Acetate Succinate based Polymeric Films using Quality by Design principles
    Damle, Shantanu
    Choudhari, Manisha
    Singhvi, Gautam
    Saha, Ranendra Narayan
    Dubey, Sunil Kumar
    SEPARATION SCIENCE PLUS, 2021, 4 (11-12) : 388 - 400