Method Development and Validation for the Simultaneous Estimation of Rosuvastatin and Amlodipine in Bulk and its Formulation using Reverse-Phase High-Performance Liquid Chromatography

被引:0
|
作者
Boggula, Narender [1 ]
Mulagada, Gowri Manoja [1 ]
Priya, D. K. Shanthi [1 ]
Bakshi, Vasudha [1 ]
Peddapalli, Himabindu [1 ]
机构
[1] Anurag Grp Inst, Sch Pharm, Dept Pharmaceut Chem, Ghatkesar, Telangana, India
关键词
Amlodipine; precision; reverse-phase high-performance liquid chromatography; rosudapin; rosuvastatin; simultaneous estimation;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: High-performance liquid chromatography (HPLC) is basically a highly improved form of column liquid chromatography. Instead of a solvent being allowed to drip through a column under gravity, it is forced through under high pressures of up to 400 atmospheres which makes it much faster. All chromatographic separations including HPLC is based upon the resolution of the sample constituents as per the difference in their relative affinities towards stationary phase and mobile phase used. Aim: A simple, specific, accurate, and precise reverse-phase HPLC method was developed and validated for the estimation of rosuvastatin and amlodipine (Rosudapin) in pharmaceutical dosage form. Materials and Methods: An Aquasil column reversed phase C-18, 5 mu m column having 4.6 mm x 250 mm i. d. in gradient mode, with mobile phase containing HPLC grade acetonitrile: phosphate buffer (pH 3.8): methanol in proportion 30: 60: 10 v/v, was used. The flow rate was 1 ml/min and effluents were monitored at 251 nm using PDA detector. Linearity was observed over a range of 5-25 mu g/mL of rosuvastatin and 2.5-12.5 mu g/mL of amlodipine, respectively. Results and Discussion: The method was validated for linearity, accuracy, precision, limit of detection, limit of quantitation, robustness, and ruggedness. The limit of detection and estimation of analytes was found to be 3.1 mu g/ml and 2.98 mu g/ml, and the limit of quantification of analytes was found to be 102 mu g/ml and 9 mu g/ml, respectively, for rosuvastatin and amlodipine. Conclusion: The proposed method was successfully applied for the quantitative determination of rosuvastatin and amlodipine in pharmaceutical dosage form.
引用
收藏
页码:S1304 / S1309
页数:6
相关论文
共 50 条
  • [21] A simplified method for the estimation of amiodarone hydrochloride by reverse-phase high performance liquid chromatography
    Thyagarajapuram, N
    Alexander, KS
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (08) : 1315 - 1326
  • [22] Development of a Rapid and Sensitive Method for the Determination of Aluminum by Reverse-Phase High-Performance Liquid Chromatography Using a Fluorescence Detector
    Heena
    Kumar, Rajesh
    Rani, Susheela
    Malik, Ashok Kumar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (05) : 800 - 806
  • [23] DEVELOPMENT AND VALIDATION OF REVERSE-PHASE HPLC METHOD FOR ESTIMATION OF KETOCONAZOLE IN BULK DRUG
    Jat, Rakesh Kumar
    Sharma, S.
    Chhipa, R. C.
    Singh, Rambir
    Alam, Imran
    PHARMACOPHORE, 2012, 3 (02): : 123 - 129
  • [24] DESALTING OF NUCLEOTIDES BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NORTHROP, DB
    NEWTON, CJ
    ANALYTICAL BIOCHEMISTRY, 1980, 103 (02) : 359 - 361
  • [25] QUANTITATION OF AMPHOTERICINS BY REVERSE-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MARGOSIS, M
    ASZALOS, A
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1984, 73 (06) : 835 - 838
  • [26] Isolation of spectrin subunits by reverse-phase high-performance liquid chromatography
    Kakhniashvili, DG
    Goodman, SR
    PROTEIN EXPRESSION AND PURIFICATION, 2001, 23 (02) : 249 - 251
  • [27] Implementation of Quality by Design Approaches for Development and Validation of Reverse-Phase High-Performance Liquid Chromatography Assay Method for Determination of Glycyrrhizin in Nanoformulation
    Halder, Jitu
    Saha, Ivy
    Rajwar, Tushar Kanti
    Kar, Biswakanth
    Ghosh, Goutam
    Rath, Goutam
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2024, 22 (01) : 28 - 39
  • [28] OPTIMIZATION OF CONDITIONS OF REVERSE-PHASE HIGH-PERFORMANCE LIQUID PROTEIN CHROMATOGRAPHY
    RYBIN, VK
    GRIGOROVA, LV
    MAKAROV, NV
    ZHURNAL FIZICHESKOI KHIMII, 1991, 65 (10): : 2649 - 2654
  • [29] Development and validation of a new reverse-phase high-performance liquid chromatography (RP-HPLC) method for the quantifications of tolperisone loaded in liposomes
    Alkaraki, Rawan N.
    Haddadin, Rula R.
    Tarawneh, Shahed K.
    Alimari, Marwa A. M.
    Alkasasbeh, Rehan M.
    Shamaileh, Tebat Al-ferdous E.
    Almohtaseb, Mustafa S.
    Hajaya, Malek G.
    RESULTS IN CHEMISTRY, 2025, 14
  • [30] Development and validation of a robust analytical method to quantify both etoposide and prodigiosin in polymeric nanoparticles by reverse-phase high-performance liquid chromatography
    Agwa, M. M.
    Elessawy, F. M.
    Hussein, A.
    El Demellawy, M. A.
    Elzoghby, A. O.
    Abd El-Salam, M. H.
    Eldiwany, A. I.
    ANALYTICAL METHODS, 2018, 10 (19) : 2272 - 2280