ELECTRON INTERFEROMETRY USING A COHERENT BEAM FROM POINT ELECTRON SOURCE

被引:0
|
作者
TONOMURA, A
机构
[1] Advanced Research Laboratory, Hitachi, Ltd., Kokubunji
来源
关键词
D O I
10.1116/1.577054
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Using the electron holography principle, a coherent field-emission electron beam is employed to quantitatively measure to a precision of 277-/100 the phase distribution of an electron wave function transmitted through or reflected from a sample. This technique opens up the possibility of previously impossible high-precision measurements such as the quantitative measurement of magnetic lines of force in a microscopic region, and thickness measurement in atomic dimensions. © 1990, American Vacuum Society. All rights reserved.
引用
收藏
页码:155 / 159
页数:5
相关论文
共 50 条
  • [21] Coherent THz radiation source driven by pre-bunched electron beam
    Zhang, H.
    Aryshev, A.
    Lancaster, A. J.
    Shevelev, M.
    Terunuma, N.
    Doucas, G.
    Konoplev, I. V.
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [22] A coherent photofield electron source for fast diffractive and point-projection imaging
    Spence, J. C. H.
    Vecchione, T.
    Weierstall, U.
    PHILOSOPHICAL MAGAZINE, 2010, 90 (35-36) : 4691 - 4702
  • [23] POINT EVAPORATOR USING ELECTRON-BEAM BOMBARDMENT
    MATSUI, S
    KAWAKATS.H
    ADACHI, K
    JOURNAL OF ELECTRON MICROSCOPY, 1973, 22 (03): : 315 - 316
  • [24] Shot noise in a coherent electron beam
    Kodama, T
    Osakabe, N
    Endo, J
    Tonomura, A
    Ohbayashi, K
    UNSOLVED PROBLEMS OF NOISE AND FLUCTUATIONS, 2000, 511 : 83 - 88
  • [25] Mechanism for correlation in a coherent electron beam
    Kodama, Tetsuji
    Osakabe, Nobuyuki
    MICROSCOPY, 2019, 68 (02) : 133 - 143
  • [26] Measurement of electron beam divergence using OTR-ODR interferometry
    Fiorito, RB
    Shkvarunets, AG
    O'Shea, PG
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 2712 - 2714
  • [27] New light source in a submillimeter to millimeter range using the coherent radiation from the single-bunch electron beam at ISIR
    Okuda, S
    Nakamura, M
    Yokoyama, K
    Kato, R
    Takahashi, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 445 (1-3): : 267 - 271
  • [28] Electron beam diagnosis on diadyn using a plasma source
    Toader, D.
    Marghitu, S.
    Craciun, G.
    Manaila, E.
    Oproiu, C.
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2010, 12 (04): : 923 - 926
  • [29] BOMBARDING ELECTRON TRAJECTORIES IN THE POINT CATHODE ELECTRON-GUN USING ELECTRON-BEAM HEATING
    IIYOSHI, R
    HARA, K
    SAKAMOTO, T
    TAKEMATSU, H
    MARUSE, S
    JOURNAL OF ELECTRON MICROSCOPY, 1987, 36 (05): : 331 - 331
  • [30] Terahertz coherent synchrotron radiation from femtosecond laser modulation of the electron beam at the Advanced Light Source
    Byrd, JM
    Hao, Z
    Martin, MC
    Robin, DS
    Sannibale, F
    Schoenlein, RW
    Zholents, AA
    Zolotorev, MS
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1606 - 1608