A fast and robust technique for 3D-2D registration of CT to single plane X-ray fluoroscopy

被引:7
|
作者
Haque, Md. Nazmul [1 ]
Pickering, Mark R. [1 ]
Al Muhit, Abdullah [1 ]
Frater, Michael R. [1 ]
Scarvell, Jennie M. [2 ]
Smith, Paul N. [2 ]
机构
[1] UNSW Canberra, Sch Engn & Informat Technol, Canberra, ACT, Australia
[2] Canberra Hosp, Trauma & Orthopaed Res Unit, Canberra, ACT, Australia
关键词
3D-2D image registration; multi-modal similarity measure; image guided surgery; kinematic analysis;
D O I
10.1080/21681163.2013.850447
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The application of 3D-2D image registration can be enormously helpful for different clinical purposes, such as imageguided surgery and the kinematic analysis of bones in knee and ankle joints. A limitation of this approach is the need to recalculate the voxel values in the 3D volume for every iteration of the registration procedure prior to generating a digitally reconstructed radiograph. In this paper we propose a new multi-phase 3D-2D image registration algorithm which uses partial 3D volumes to estimate out-of-plane rotations. In our proposed algorithm, only one full 3D update is used to generate a 2D projection during the registration procedure. Experimental results show that our proposed method can provide a registration accuracy similar to the commonly used approach which employs 3D updates at every iteration. As a result of reducing the number of 3D updates, the proposed approach reduces the time required to carry out the registration by a factor of 10-20 without any accompanying loss of registration accuracy.
引用
下载
收藏
页码:76 / 89
页数:14
相关论文
共 50 条
  • [41] Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
    Vernikouskaya, Ina
    Rottbauer, Wolfgang
    Seeger, Julia
    Gonska, Birgid
    Woehrle, Jochen
    Rasche, Volker
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (136):
  • [42] 3D-2D spatiotemporal registration for sports motion analysis
    Wang, Ruixuan
    Leow, Wee Kheng
    Leong, Hon Wai
    2008 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-12, 2008, : 1444 - 1451
  • [43] A Statistical Framework for the Registration of 3D Knee Implant Components to Single-Plane X-Ray Images
    Hermans, J.
    Bellemans, J.
    Maes, F.
    Vandermeulen, D.
    Suetens, P.
    2008 IEEE COMPUTER SOCIETY CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION WORKSHOPS, VOLS 1-3, 2008, : 402 - +
  • [44] 3D CT to 2D Low Dose Single-Plane Fluoroscopy Registration Algorithm for In-vivo Knee Motion Analysis
    Akter, Masuma
    Lambert, Andrew J.
    Pickering, Mark R.
    Scarvell, Jennie M.
    Smith, Paul N.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 5121 - 5124
  • [45] Transgraph: interactive intensity-based 2D/3D registration of X-ray and CT data
    LaRose, D
    Bayouth, J
    Kanade, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 385 - 396
  • [46] Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
    van der Bom, M. J.
    Pluim, J. P. W.
    Gounis, M. J.
    de Kraats, E. B. van
    Sprinkhuizen, S. M.
    Timmer, J.
    Homan, R.
    Bartels, L. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1031 - 1043
  • [47] Real-time registration of 3D echo to x-ray fluoroscopy based on cascading classifiers and image registration
    Ma, YingLiang
    James Housden, R.
    Fazili, Ansab
    Arujuna, Aruna, V
    Rhode, Kawal S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (05):
  • [48] Thorax x-ray and CT interventional dataset for nonrigid 2D/3D image registration evaluation
    Xia, Wei
    Jin, Qingpeng
    Ni, Caifang
    Wang, Yanling
    Gao, Xin
    MEDICAL PHYSICS, 2018, 45 (11) : 5343 - 5351
  • [49] Accurate and precise 2D-3D registration based on X-ray intensity
    Aouadi, Souha
    Sarry, Laurent
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (01) : 134 - 151
  • [50] Correction of patient motion in cone-beam CT using 3D-2D registration
    Ouadah, S.
    Jacobson, M.
    Stayman, J. W.
    Ehtiati, T.
    Weiss, C.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 8813 - 8831