OPTICAL FILTERING AND SPECTRAL MEASUREMENTS OF RADIATION-INDUCED LIGHT IN PLASTIC SCINTILLATION DOSIMETRY

被引:135
|
作者
DEBOER, SF [1 ]
BEDDAR, AS [1 ]
RAWLINSON, JA [1 ]
机构
[1] PRINCESS MARGARET HOSP,ONTARIO CANC INST,DEPT CLIN PHYS,TORONTO M4X 1K9,ONTARIO,CANADA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1993年 / 38卷 / 07期
关键词
D O I
10.1088/0031-9155/38/7/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A small, water-equivalent plastic scintillation detector system has previously been developed for radiation therapy dosimetry. A light signal, proportional to dose, is generated in the scintillator and is transmitted to a remote photomultiplier tube (PMT) via optical fibres. Ionizing radiation also produces light in the fibres, which, if not properly accounted for, could limit the accuracy of the scintillator system. The fibre light is shown to have both a Cerenkov radiation and fluorescent component. The differences in the measured optical spectra of the fibre light and plastic scintillator light lead to the possibility of reducing the fibre light component by optical filtering. Optical spectral measurements of a commercially available orange-emitting plastic scintillator revealed that incomplete light-wavelength-shifting to the orange region of the visible spectrum occurs due to the size of the small scintillators that were used. Spectral measurements of orange and green scintillators with higher concentrations of wavelength-shifting fluor have been performed. Quantitative results indicate that using the highest doped orange scintillator and appropriate optical filter can decrease the fibre light contribution by about 50% when compared to the conventional blue scintillator, non-filtered case in typical radiotherapy dosimetry situations.
引用
收藏
页码:945 / 958
页数:14
相关论文
共 50 条
  • [21] RADIATION-INDUCED OPTIC NEUROPATHY - CORRELATION OF MR IMAGING AND RADIATION-DOSIMETRY
    YOUNG, WC
    THORNTON, AF
    GEBARSKI, SS
    CORNBLATH, WT
    RADIOLOGY, 1992, 185 (03) : 904 - 907
  • [22] Radiation-induced modifications of point defects in quartz crystals and their application in radiation dosimetry
    Bahadur, H
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 493 - 497
  • [23] Multiple wavelength analysis of radiation-induced attenuation on optical fibers:: A novel approach in fiber optic dosimetry
    Borgermans, P
    Noël, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1998, 47 (05) : 1255 - 1258
  • [24] STRESS- AND RADIATION-INDUCED SWELLING IN PLASTIC CAPSULES
    Harding, D. R.
    Shmayda, W. T.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 63 (02) : 125 - 131
  • [25] Radiation-induced compaction and plastic flow of vitreous silica
    CIRIL-Cent Interdisciplinaire de, Recherche avec les Ions Lourds, Caen, France
    Nucl Instrum Methods Phys Res Sect B, 1-4 (449-454):
  • [26] Radiation-induced compaction and plastic flow of vitreous silica
    Benyagoub, A
    Klaumünzer, S
    Toulemonde, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1998, 146 (1-4): : 449 - 454
  • [27] INFLUENCE OF DEFECTS ON RADIATION-INDUCED PROCESSES IN CADMIUM TUNGSTATE SCINTILLATION CRYSTALS
    Tupitsyna, I. A.
    Grinyov, B. V.
    Nagornaya, L. L.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2009, (04): : 145 - 149
  • [28] RADIATION-INDUCED VARIATIONS IN THE SPECTRAL CHARACTERISTICS OF InxAs:Si LIGHT-EMITTING DIODES.
    Torchinskaya, T.V.
    Semenova, G.N.
    Berdinskikh, T.G.
    Brailovskii, E.Yu.
    Journal of applied spectroscopy, 1986, 45 (02) : 828 - 833
  • [29] Radiation-induced optical emission quenching in light-probed silica core fibers
    P. V. Demenkov
    O. A. Plaksin
    V. A. Stepanov
    P. A. Stepanov
    Technical Physics Letters, 2002, 28 : 59 - 60
  • [30] Radiation-induced optical emission quenching in light-probed silica core fibers
    Demenkov, PV
    Plaksin, OA
    Stepanov, VA
    Stepanov, PA
    TECHNICAL PHYSICS LETTERS, 2002, 28 (01) : 59 - 60