Uncertainty in positioning ion chamber at reference depth for various water phantoms

被引:7
|
作者
Kinoshita, Naoki [1 ,2 ]
Oguchi, Hiroshi [1 ]
Adachi, Toshiki [2 ]
Shioura, Hiroki [3 ]
Kimura, Hirohiko [3 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Nagoya, Aichi 4618673, Japan
[2] Univ Fukui Hosp, Radiol Ctr, Eiheiji, Fukui 9101193, Japan
[3] Univ Fukui Hosp, Dept Radiol, Eiheiji, Fukui 9101193, Japan
关键词
Positioning uncertainty; Ionization chamber; Water phantom; External photon beam radiotherapy; Calibration;
D O I
10.1016/j.rpor.2018.03.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Uncertainty in the calibration of high-energy radiation sources is dependent on user and equipment type. Aim: We evaluated the uncertainty in the positioning of a cylindrical chamber at a reference depth for reference dosimetry of high-energy photon beams and the resulting uncertainty in the chamber readings for 6- and 10-MV photon beams. The aim was to investigate major contributions to the positioning uncertainty to reduce the uncertainty in calibration for external photon beam radiotherapy. Materials and methods: The following phantoms were used: Dose View 1D, WP1D, 1D SCAN-NER, and QWP-07 as one-dimensional (1D) phantoms for a vertical-beam geometry; GRI-7632 as a phantom for a fixed waterproofing sleeve; and PTW type 41023 and QWP-04 as 1D phantoms for a horizontal-beam geometry. The uncertainties were analyzed as per the Guide to the Expression of Uncertainty in Measurement. Results: The positioning and resultant uncertainties in chamber readings ranged from 0.22 to 0.35 mm and 0.12-0.25%, respectively, among the phantoms (using a coverage factor k = 1 in both cases). The major contributions to positioning uncertainty are: definition of the origin for phantoms among users for the 1D phantoms for a vertical-beam geometry, water level adjustment among users for the phantom for a fixed waterproofing sleeve, phantom window deformation, and non-water material of the window for the 1D phantoms for a horizontal-beam geometry. Conclusion: The positioning and resultant uncertainties in chamber readings exhibited minor differences among the seven phantoms. The major components of these uncertainties differed among the phantom types investigated. (c) 2018 Greater Poland Cancer Centre. Published by Elsevier Sp.zo.o. All rights reserved.
引用
收藏
页码:199 / 206
页数:8
相关论文
共 50 条
  • [1] Uncertainty in Positioning Ion Chamber at Reference Depth for Various Water Phantoms
    Kinoshita, N.
    Oguchi, H.
    Nishimoto, Y.
    Adachi, T.
    Shioura, H.
    Kimura, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 2932 - 2932
  • [2] Assessment of depth uncertainty and its influence on dose measurement in water phantoms
    Chimeno, J.
    Gimeno-Olmos, J.
    Ruiz-Rodriguez, J. C.
    Carmona, V.
    Lliso-Valverde, F.
    Perez-Calatayud, J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S697 - S698
  • [3] Depth of ionization chamber in water
    Phys Med Biol, 8 (1389):
  • [4] Impact of air around an ion chamber: solid water phantoms not suitable for dosimetry on an MR-linac
    Hackett, S.
    Van Asselen, B.
    Wolthaus, J.
    Kok, J.
    Woodings, S.
    Lagendijk, J.
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S34 - S35
  • [5] TAKING INTO ACCOUNT THE UNCERTAINTY OF THE IONISATION CHAMBER POSITIONING IN IMRT VERIFICATIONS
    Richart Sancho, J.
    Perez-Calatayud, J.
    Rodriguez Villalba, S.
    Santos, M.
    Ballester, F.
    Granero, D.
    Lliso, F.
    Carmona, V.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S217 - S217
  • [6] DEPTH OF IONIZATION-CHAMBER IN WATER
    TAILOR, RC
    TELLO, VM
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (08): : 1389 - 1392
  • [7] Does head positioning influence anterior chamber depth in pseudoexfoliation syndrome?
    Lanzl, IM
    Merté, RL
    Graham, AD
    JOURNAL OF GLAUCOMA, 2000, 9 (03) : 214 - 218
  • [9] Examining the Influence of Humidity On Reference Ion Chamber Performance
    Taank, J.
    McEwen, M.
    MEDICAL PHYSICS, 2016, 43 (06) : 3850 - 3850
  • [10] Positioning by cost reference particle filters:: Study of various implementations
    Bugallo, MF
    Míguez, J
    Djuric, PM
    EUROCON 2005: THE INTERNATIONAL CONFERENCE ON COMPUTER AS A TOOL, VOL 1 AND 2 , PROCEEDINGS, 2005, : 1610 - 1613