OPTIMIZED BIOSENSOR FOR WHOLE-BLOOD MEASUREMENTS USING A NEW CELLULOSE-BASED MEMBRANE

被引:20
|
作者
EISELE, S
AMMON, HPT
KINDERVATER, R
GROBE, A
GOPEL, W
机构
[1] FRAUNHOFER INST SURFACES & BIOENGN,W-7000 STUTTGART,GERMANY
[2] UNIV TUBINGEN,INST PHYS & THEORET CHEM,W-7400 TUBINGEN 1,GERMANY
来源
BIOSENSORS & BIOELECTRONICS | 1994年 / 9卷 / 02期
关键词
AMPEROMETRIC; GLUCOSE SENSOR; GOD; LONG-TERM STABILITY; LINEARITY RANGE; CUPROPHAN(R); BACTERIAL CELLULOSE; DILUTED BLOOD; WHOLE BLOOD;
D O I
10.1016/0956-5663(94)80102-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We used bacterial cellulose membranes as outer membranes for glucose sensors based upon amperometric detection of glucose oxidase reaction products. We found a long-term stability in 1:10 diluted blood of about 200 h. In comparison a Cuprophan(R) membrane was stable for only 30 h under the same conditions. Comparing the two membranes in undiluted human blood, a similar trend was found in the long-term stability: Cuprophan(R) was stable for only 3-4 h and the glucose sensor with the bacterial cellulose membrane was stable for more than 24 h. In addition, the measuring range of the glucose sensor could be extended up to 170 mM glucose by treating the bacterial cellulose membrane with a polyamide.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [41] ANALYTICAL ARTIFACTS IN HEMATOCRIT MEASUREMENTS BY WHOLE-BLOOD CHEMISTRY ANALYZERS
    STOTT, RAW
    HORTIN, GL
    WILHITE, TR
    MILLER, SB
    SMITH, CH
    LANDT, M
    CLINICAL CHEMISTRY, 1995, 41 (02) : 306 - 311
  • [42] EFFECT OF HEPARIN ON WHOLE-BLOOD ACTIVATED PARTIAL THROMBOPLASTIN TIME USING A PORTABLE, WHOLE-BLOOD COAGULATION MONITOR
    DESPOTIS, GJ
    HOGUE, CW
    SANTORO, SA
    JOIST, JH
    BARNES, PW
    LAPPAS, DG
    CRITICAL CARE MEDICINE, 1995, 23 (10) : 1674 - 1679
  • [43] Degradation of new cellulose-based complex material
    Ou, YF
    Huang, QL
    Chen, JN
    JOURNAL OF APPLIED POLYMER SCIENCE, 2001, 81 (04) : 809 - 812
  • [44] An optimized method for elution of enteroviral RNA from a cellulose-based substrate
    Li, Yan
    Yoshida, Hiromu
    Wang, Lu
    Tao, Zexin
    Wang, Haiyan
    Lin, Xiaojuan
    Xu, Aiqiang
    JOURNAL OF VIROLOGICAL METHODS, 2012, 186 (1-2) : 62 - 67
  • [45] A NEW SENSITIVE METHOD FOR DETERMINING ENDOTOXIN IN WHOLE-BLOOD
    TAMURA, H
    TANAKA, S
    OBAYASHI, T
    YOSHIDA, M
    KAWAI, T
    CLINICA CHIMICA ACTA, 1991, 200 (01) : 35 - 42
  • [46] Fabrication of Pt based amperometric cholesterol biosensor using cellulose acetate membrane
    Vikas
    Pundir, C. S.
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2008, 67 (04): : 299 - 306
  • [47] DIAGNOSTIC UTILITY OF WHOLE-BLOOD CYCLOSPORINE MEASUREMENTS IN RENAL-TRANSPLANTATION USING TRIPLE THERAPY
    NANKIVELL, BJ
    HIBBINS, M
    CHAPMAN, JR
    TRANSPLANTATION, 1994, 58 (09) : 989 - 996
  • [48] NEW DEVICE FOR RAPID MEASUREMENT OF BUN IN WHOLE-BLOOD
    YOSHINO, F
    KANAGAWA
    HARADA, K
    CLINICAL CHEMISTRY, 1983, 29 (06) : 1178 - 1178
  • [49] NEW METHOD FOR DETERMINATION OF WHOLE-BLOOD IRON AND HEMOGLOBIN
    CONNERTY, HV
    BRIGGS, AR
    CLINICAL CHEMISTRY, 1962, 8 (02) : 151 - &
  • [50] VALIDITY AND PRECISION OF TOTAL CHOLESTEROL MEASUREMENTS USING A REFLOTRON(R) ANALYZER WITH WHOLE-BLOOD AND PLASMA
    KAMINSKY, LA
    WHALEY, MH
    MACKLIN, D
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1992, 63 (01) : A24 - A24