OPTIMIZED BIOSENSOR FOR WHOLE-BLOOD MEASUREMENTS USING A NEW CELLULOSE-BASED MEMBRANE

被引:20
|
作者
EISELE, S
AMMON, HPT
KINDERVATER, R
GROBE, A
GOPEL, W
机构
[1] FRAUNHOFER INST SURFACES & BIOENGN,W-7000 STUTTGART,GERMANY
[2] UNIV TUBINGEN,INST PHYS & THEORET CHEM,W-7400 TUBINGEN 1,GERMANY
来源
BIOSENSORS & BIOELECTRONICS | 1994年 / 9卷 / 02期
关键词
AMPEROMETRIC; GLUCOSE SENSOR; GOD; LONG-TERM STABILITY; LINEARITY RANGE; CUPROPHAN(R); BACTERIAL CELLULOSE; DILUTED BLOOD; WHOLE BLOOD;
D O I
10.1016/0956-5663(94)80102-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We used bacterial cellulose membranes as outer membranes for glucose sensors based upon amperometric detection of glucose oxidase reaction products. We found a long-term stability in 1:10 diluted blood of about 200 h. In comparison a Cuprophan(R) membrane was stable for only 30 h under the same conditions. Comparing the two membranes in undiluted human blood, a similar trend was found in the long-term stability: Cuprophan(R) was stable for only 3-4 h and the glucose sensor with the bacterial cellulose membrane was stable for more than 24 h. In addition, the measuring range of the glucose sensor could be extended up to 170 mM glucose by treating the bacterial cellulose membrane with a polyamide.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [31] RAPID MEASUREMENTS OF GLUCOSE AND URIC-ACID IN WHOLE-BLOOD USING THE ENZYME ELECTRODES
    YOSHINO, F
    OSAWA, H
    CLINICAL CHEMISTRY, 1980, 26 (07) : 1060 - 1060
  • [32] NEUTROPHIL IODINATION TEST USING WHOLE-BLOOD
    GRAY, BM
    CLINICAL RESEARCH, 1979, 27 (05): : A809 - A809
  • [33] USE OF AN OPTICAL BIOSENSOR TO MEASURE PROSTATE-SPECIFIC ANTIGEN IN WHOLE-BLOOD
    ONEILL, PM
    FLETCHER, JE
    STAFFORD, CG
    DANIELS, PB
    BACARESEHAMILTON, T
    SENSORS AND ACTUATORS B-CHEMICAL, 1995, 29 (1-3) : 79 - 83
  • [34] Investigation of Prothrombin Time in Human Whole-Blood Samples with a Quartz Crystal Biosensor
    Mueller, Lothar
    Sinn, Stefan
    Drechsel, Hartmut
    Ziegler, Christiane
    Wendel, Hans-Peter
    Northoff, Hinnak
    Gehring, Frank K.
    ANALYTICAL CHEMISTRY, 2010, 82 (02) : 658 - 663
  • [35] EFFECT OF INTRALIPID ON MEASUREMENTS OF TOTAL HEMOGLOBIN AND OXYHEMOGLOBIN IN WHOLE-BLOOD
    SEHGAL, LR
    SEHGAL, HL
    ROSEN, AL
    GOULD, SA
    MOSS, GS
    CRITICAL CARE MEDICINE, 1984, 12 (10) : 907 - 909
  • [36] DETERMINATION OF MO IN WHOLE-BLOOD USING GFAAS
    RIDAO, M
    CSEH, SB
    DRAKE, M
    ATOMIC SPECTROSCOPY, 1994, 15 (02) : 87 - 89
  • [37] Recent Advances in Cellulose-Based Forward Osmosis Membrane
    Lu, Peng
    Gao, Yanshan
    Umar, Ahmad
    Zhou, Tuantuan
    Wang, Junya
    Zhang, Zhang
    Huang, Liang
    Wang, Qiang
    SCIENCE OF ADVANCED MATERIALS, 2015, 7 (10) : 2182 - 2192
  • [38] OPTICAL MEASUREMENTS IN WHOLE-BLOOD OF TRACERS FOR LUNG MICROVASCULAR PERMEABILITY
    OLSON, LE
    GALLOWAY, RL
    POU, A
    HARRIS, TR
    FASEB JOURNAL, 1991, 5 (04): : A754 - A754
  • [39] SEPARATION OF PLASMA FROM WHOLE-BLOOD WITH MICROPOROUS MEMBRANE SYSTEMS
    LYSAGHT, MJ
    SALOMON, B
    COLTON, CK
    FRIEDMAN, L
    CASTINO, F
    OBERHAUSER, C
    CHEMIKER-ZEITUNG, 1978, 102 (03): : 105 - 105
  • [40] Effect of storage on phenylalanine and tyrosine measurements in whole-blood samples
    Beck, M
    Bökenkamp, A
    Liappis, N
    Lentze, MJ
    CLINICAL CHEMISTRY, 2001, 47 (04) : 751 - 753