PRECISION IN QUANTITATIVE CT - IMPACT OF X-RAY DOSE AND MATRIX SIZE

被引:8
|
作者
GOODSITT, MM [1 ]
JOHNSON, RH [1 ]
机构
[1] UNIV WASHINGTON,DEPT BIOENGN,SEATTLE,WA 98195
关键词
COMPUTED TOMOGRAPHY (CT); DUAL-ENERGY; PRECISION; X-RAY DOSE; BONE MINERAL;
D O I
10.1118/1.596820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A study was performed to determine whether recommended technique factors for post-processing dual-energy (DE) quantitative computed tomography are optimum in terms of precision and x-ray dose. In particular, possible dose reduction as a result of an upgrade of the CT scanner to more efficient detectors was explored. Series of images of an anthropomorphic phantom containing a human vertebra, a tissue-simulating lumbar simulator with various marrow inserts, and a polyethylene cylinder were generated. Recommended DE x-ray technique factors as well as factors resulting in about two times, one-half, and one-fourth the x-ray dose were employed. The effects of reconstruction with different matrix sizes was studied. Standard deviations of the CT numbers within regions of interest in individual images (noise) and standard deviations of mean CT numbers, single-energy (SE), and DE measurements for series of images (reproducibilities) were computed. It was found that the low-energy component of the DE technique was optimum, but the high-energy component could be reduced by a factor of 2 with negligible loss in precision. This translates into a dose reduction of 36% relative to the recommended DE technique. Vertebral inhomogeneities were responsible for more than 65% of the standard deviations in individual images of the vertebra even at the lowest doses. For all of the techniques, the noise in images of all objects decreased as the x-ray dose increased and as the matrix size decreased. Reproducibility of mean values, however, did not necessarily improve, and aberrant results such as improvement in reproducibility with a reduction in dose were sometimes observed. It is hypothesized that this may be due to variations in the actual kVp for each image in a series.
引用
收藏
页码:1025 / 1036
页数:12
相关论文
共 50 条
  • [31] X-RAY DOSE ENHANCEMENT
    CHADSEY, WL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (06) : 1591 - 1597
  • [32] Quantitative X-ray tomography
    Maire, E.
    Withers, P. J.
    INTERNATIONAL MATERIALS REVIEWS, 2014, 59 (01) : 1 - 43
  • [33] X-RAY FORMAT AND DOSE
    MAURER, HJ
    RONTGEN-BLATTER KLINIK UND PRAXIS, 1978, 31 (02): : 93 - 104
  • [34] X-ray matrix sensors
    Kolodziej, A
    Krewniak, P
    Tadeusiewicz, R
    OPTOELECTRONIC AND ELECTRONIC SENSORS III, 1999, 3730 : 214 - 219
  • [35] A new precision x-ray spectrometer
    Soller, W
    PHYSICAL REVIEW, 1924, 24 (02): : 158 - 167
  • [36] On precision x-ray radioscopies.
    Rosenthal, J
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1918, 44 : 185 - 185
  • [37] High Precision X-Ray Measurements
    Scordo, Alessandro
    CONDENSED MATTER, 2019, 4 (02):
  • [38] PRECISION IN X-RAY EMISSION SPECTROGRAPHY
    LIEBHAFSKY, HA
    PFEIFFER, HG
    ZEMANY, PD
    ANALYTICAL CHEMISTRY, 1955, 27 (08) : 1257 - 1258
  • [39] Precision x-ray wavelength measurements
    Parratt, LG
    PHYSICAL REVIEW, 1935, 47 (11): : 0882 - 0883
  • [40] A PRECISION X-RAY POWDER CAMERA
    FRONDEL, C
    AMERICAN MINERALOGIST, 1955, 40 (9-10) : 876 - 884