PRECISION IN QUANTITATIVE CT - IMPACT OF X-RAY DOSE AND MATRIX SIZE

被引:8
|
作者
GOODSITT, MM [1 ]
JOHNSON, RH [1 ]
机构
[1] UNIV WASHINGTON,DEPT BIOENGN,SEATTLE,WA 98195
关键词
COMPUTED TOMOGRAPHY (CT); DUAL-ENERGY; PRECISION; X-RAY DOSE; BONE MINERAL;
D O I
10.1118/1.596820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A study was performed to determine whether recommended technique factors for post-processing dual-energy (DE) quantitative computed tomography are optimum in terms of precision and x-ray dose. In particular, possible dose reduction as a result of an upgrade of the CT scanner to more efficient detectors was explored. Series of images of an anthropomorphic phantom containing a human vertebra, a tissue-simulating lumbar simulator with various marrow inserts, and a polyethylene cylinder were generated. Recommended DE x-ray technique factors as well as factors resulting in about two times, one-half, and one-fourth the x-ray dose were employed. The effects of reconstruction with different matrix sizes was studied. Standard deviations of the CT numbers within regions of interest in individual images (noise) and standard deviations of mean CT numbers, single-energy (SE), and DE measurements for series of images (reproducibilities) were computed. It was found that the low-energy component of the DE technique was optimum, but the high-energy component could be reduced by a factor of 2 with negligible loss in precision. This translates into a dose reduction of 36% relative to the recommended DE technique. Vertebral inhomogeneities were responsible for more than 65% of the standard deviations in individual images of the vertebra even at the lowest doses. For all of the techniques, the noise in images of all objects decreased as the x-ray dose increased and as the matrix size decreased. Reproducibility of mean values, however, did not necessarily improve, and aberrant results such as improvement in reproducibility with a reduction in dose were sometimes observed. It is hypothesized that this may be due to variations in the actual kVp for each image in a series.
引用
收藏
页码:1025 / 1036
页数:12
相关论文
共 50 条
  • [21] Absorbed Dose to the Conceptus and Patient Size in X-Ray Projection Imaging
    Magill, D.
    Huda, W.
    He, W.
    Tipnis, S.
    Mah, E.
    Frey, G.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [22] The effect of x-ray CT dose on normoxic polymer gel dosimeters
    Baxter, P.
    Jirasek, A.
    Hilts, M.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S56 - S56
  • [23] Nonlinear sinogram smoothing for low-dose X-ray CT
    Li, TF
    Li, X
    Wang, J
    Wen, JH
    Lu, HB
    Hsieh, J
    Liang, ZR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2505 - 2513
  • [24] A spectral X-ray CT simulation study for quantitative determination of iron
    Su, Ting
    Kaftandjian, Valerie
    Duvauchelle, Philippe
    Zhu, Yuemin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 894 : 39 - 46
  • [25] Quantitative method of measuring spot size of microfocus X-ray generator
    Uchida, Hiroyuki
    Hasuike, Kazuto
    Torii, Ken'ichi
    Tsunemi, Hiroshi
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (6A): : 5277 - 5279
  • [26] Statistical Comparison of Likelihood Models for Low Dose X-ray CT
    Perlmutter, David S.
    Kim, Soo Mee
    Kinahan, Paul E.
    Alessi, Adam M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [27] X-ray CT system working on dose reduction of medical exposure
    Gotanda K.
    Seimitsu Kogaku Kaishi/Journal of the Japan Society for Precision Engineering, 2019, 85 (09): : 765 - 768
  • [28] Investigation of X-ray CT dose in normoxic polyacrylamide gel dosimetry
    Jirasek, A.
    Baxter, P.
    Hilts, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1873 - +
  • [29] Quantitative X-Ray inspection
    Retraint, F
    Dinten, JM
    Campagnolo, R
    Peyrin, F
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 363 - 370
  • [30] QUANTITATIVE X-RAY ANALYSIS
    PAPE, A
    STUPIN, DM
    SENS, JC
    FINTZ, P
    GALLMANN, A
    GOVE, HE
    GUILLAUME, G
    NUCLEAR INSTRUMENTS & METHODS, 1972, 105 (01): : 161 - +