A BIOSENSOR FOR THE ANALYSIS OF HYDROGEN-PEROXIDE

被引:0
|
作者
CHARPENTIER, L [1 ]
MURR, NE [1 ]
机构
[1] FAC SCI & TECH NANTES,ELECTROCHIM GRP,RMN & REACTIV CHIM LAB,URA 472,F-44072 NANTES 03,FRANCE
关键词
HYDROGEN PEROXIDE; PEROXIDASE; ENZYME ELECTRODE; CARBON PASTE; MEDIATOR;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A biosensor for the analysis of hydrogen peroxide. A biosensor has been developed for quick and selective measurements of hydrogen peroxide. The sensor is made of carbon paste containing in its bulk a redox mediator and the peroxidase. The advantages of such a structure are that the surface of the sensor can be easily renewable by simple scratching on a paper surface and that the enzyme and the mediator are kept in close vicinity which allows the electron transfer to occur. Different parameters have been studied in order to optimize the response of the biosensor. This sensor can be used for quick determination (30s) of hydrogen peroxide in the concentration range of 10(6) to 2 10(-4) M. The signal is stable for more than 1.5 year.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 50 条
  • [1] FIBEROPTIC BIOSENSOR FOR DETERMINATION OF HYDROGEN-PEROXIDE
    HLAVAY, J
    GUILBAULT, GG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 147 - ANYL
  • [2] CATALASE BIOSENSOR FOR THE DETERMINATION OF HYDROGEN-PEROXIDE, FLUORIDE AND CYANIDE
    STEIN, K
    HAIN, JU
    MIKROCHIMICA ACTA, 1995, 118 (1-2) : 93 - 101
  • [3] SPECTROFLUOROMETRIC ANALYSIS OF HYDROGEN-PEROXIDE
    BLACK, MJ
    BRANDT, RB
    ANALYTICAL BIOCHEMISTRY, 1974, 58 (01) : 246 - 254
  • [4] KOHLRABI-BASED AMPEROMETRIC BIOSENSOR FOR HYDROGEN-PEROXIDE MEASUREMENT
    CHEN, L
    LIN, MS
    HARA, M
    RECHNITZ, GA
    ANALYTICAL LETTERS, 1991, 24 (01) : 1 - 14
  • [5] HYDROGEN-PEROXIDE
    VAUGHANJONES, C
    BRITISH DENTAL JOURNAL, 1995, 178 (03) : 93 - 93
  • [6] BIOSENSOR FOR DETERMINATION OF HYDROGEN-PEROXIDE BASED ON CATALASE ACTIVITY OF HUMAN ERYTHROCYTES
    RACEK, J
    PETR, R
    ANALYTICA CHIMICA ACTA, 1990, 239 (01) : 19 - 22
  • [7] Measurement of hydrogen-peroxide in an advanced oxidation process using an automated biosensor
    Modrzejewska, B.
    Guwy, A. J.
    Dinsdale, R.
    Hawkes, D. L.
    WATER RESEARCH, 2007, 41 (01) : 260 - 268
  • [8] HYDROGEN-PEROXIDE OXYGEN BIOSENSOR BASED ON SUPPORTED PHOSPHOLIPID-BILAYER
    OTTO, M
    SNEJDARKOVA, M
    REHAK, M
    ANALYTICAL LETTERS, 1992, 25 (04) : 653 - 662
  • [9] PHOTOREDUCTION OF HYDROGEN-PEROXIDE BY HYDROGEN
    FIELD, RJ
    NOYES, RM
    POSTLETHWAITE, D
    JOURNAL OF PHYSICAL CHEMISTRY, 1976, 80 (03): : 223 - 229
  • [10] ANALYSIS OF HYDROGEN-PEROXIDE IN FRESHLY PREPARED COFFEES
    RINKUS, SJ
    TAYLOR, RT
    FOOD AND CHEMICAL TOXICOLOGY, 1990, 28 (05) : 323 - 331