Tracheal intubation in patients with cervical spine immobilization: A comparison of McGrath((R)) video laryngoscope and Truview EVO2((R)) laryngoscope

被引:9
|
作者
Bhola, Ruchi [1 ]
Bhalla, Swaran [1 ]
Gupta, Radha [1 ]
Singh, Ishwar [1 ]
Kumar, Sunil [2 ]
机构
[1] Jaipur Golden Hosp, Dept Anaesthesiol, Rohini, India
[2] Max Hosp, New Delhi, India
关键词
McGrath video laryngoscope; simulated difficult airway; Truview laryngoscope;
D O I
10.4103/0019-5049.135035
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Literature suggests that glottic view is better when using McGrath (R) Video laryngoscope and Truview (R) in comparison with McIntosh blade. The purpose of this study was to evaluate the effectiveness of McGrath Video laryngoscope in comparison with Truview laryngoscope for tracheal intubation in patients with simulated cervical spine injury using manual in-line stabilisation. Methods: This prospective randomised study was undertaken in operation theatre of a tertiary referral centre after approval from the Institutional Review Board. A total of 100 consenting patients presenting for elective surgery requiring tracheal intubation were randomly assigned to undergo intubation using McGrath (R) Video laryngoscope (n = 50) or Truview (R) (n = 50) laryngoscope. In all patients, we applied manual-in-line stabilisation of the cervical spine throughout the airway management. Statistical testing was conducted with the statistical package for the social science system version SPSS 17.0. Demographic data, airway assessment and haemodynamics were compared using the Chi-square test. A P < 0.05 was considered significant. Results: The time to successful intubation was less with McGrath video laryngoscope when compared to Truview (30.02 s vs. 38.72 s). However, there was no significant difference between laryngoscopic views obtained in both groups. The number of second intubation attempts required and incidence of complications were negligible with both devices. Success rate of intubation with both devices was 100%. Intubation with McGrath Video laryngoscope caused lesser alterations in haemodynamics. Conclusions: Both laryngoscopes are reliable in case of simulated cervical spine injury using manual-in-line stabilisation with 100% success rate and good glottic view.
引用
下载
收藏
页码:269 / 274
页数:6
相关论文
共 50 条
  • [41] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Yoo, Ji Young
    Chae, Yun Jeong
    Lee, Young Bok
    Kim, Sujin
    Lee, Jaemoon
    Kim, Dae Hee
    SCIENTIFIC REPORTS, 2018, 8
  • [42] A possible explanation for cricoid pressure to improve the laryngeal view with the Truview Evo2™ laryngoscope Reply
    Kumar, Nishant
    Behera, Debadutta
    Dali, Jaspal Singh
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (12): : 1147 - 1148
  • [43] Direct laryngoscope versus McGRATH video-laryngoscope for tracheal intubation in trauma emergency: A randomised control trial
    Ajith, P.
    Bandyopadhyay, Anjishnujit
    Meena, Shyam Charan
    Jain, Kajal
    Aggarwal, Sameer
    Gupta, Sunil Kumar
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 56 : 353 - 355
  • [44] TRACHEAL INTUBATION WITH A MCGRATH® SERIES 5 VIDEO LARYNGOSCOPE BY NOVICE PERSONNEL IN A CERVICAL-IMMOBILIZED MANIKIN
    Choi, Ji Won
    Kim, Jie Ae
    Jung, Hyun Joo
    Kim, Won Ho
    JOURNAL OF EMERGENCY MEDICINE, 2016, 50 (01): : 61 - 66
  • [45] The McGrath video laryngoscope in unstable cervical spine surgery: a case series
    Hughes, Christopher G.
    Mathews, Letha
    Easdown, Jane
    Pandharipande, Pratik P.
    JOURNAL OF CLINICAL ANESTHESIA, 2010, 22 (07) : 575 - 576
  • [46] Comparison of a New Video Intubation Stylet and McGrath® MAC Video Laryngoscope for Intubation in an Airway Manikin with Normal Airway and Cervical Spine Immobilization Scenarios by Novice Personnel: A Randomized Crossover Study
    Park, Jin-Woo
    An, Sungmin
    Park, Seongjoo
    Nahm, Francis Sahngun
    Han, Sung-Hee
    Kim, Jin-Hee
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [47] A Comparison of the GlideScope® Video Laryngoscope to the C-MAC® Video Laryngoscope for Tracheal Intubation in the Emergency Department
    Sakles, J. C.
    Mosier, J.
    Chiu, S.
    Patanwala, A.
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (04) : S63 - S63
  • [48] Awake tracheal intubation using king Vision video laryngoscope in traumatic cervical spine patients: A case series
    Ahmad, Sarfaraz
    Sahay, Nishant
    Naaz, Shagufta
    Singh, Kunal
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2022, 45 : 55 - 57
  • [49] Comparison of McGrath videolaryngoscope with conventional Macintosh laryngoscope for tracheal intubation in pediatric patients with normal airway
    Bhamri, Stuti
    Desai, Devyani
    Chauhan, Darshit
    Cheraya, Neha
    INDIAN ANAESTHETISTS FORUM, 2023, 24 (01): : 43 - 48
  • [50] Comparison of Airtraq™ video-laryngoscope and Macintosh laryngoscope for tracheal intubation in adults—a randomised study
    Seema Meena
    Sujata Chaudhary
    Rashmi Salhotra
    Swati Bharti
    Bismanjeet Kaur Khurana
    Ain-Shams Journal of Anesthesiology, 15